Product Documentation and Compliance Information for the Cisco IE 4010 and Cisco IE 5000 Switches—Documentation sur le
produit et informations relatives à la conformité pour les commutateurs Cisco IE 4010 et Cisco IE 5000.
Installing a Power-Supply Module—Installation d'un module d'alimentation
Note
The power-supply module 1 connection is labeled PSU1, and the power-supply module 2 connection is
labeled PSU2. Make sure that you connect the wires to the correct terminal screws.
3.
Use twisted-pair copper wire (18- to 14-AWG or 0.82- to 2.08-mm
2
) to connect from the power-input terminal to
the power source.
Note
Use 12-AWG or 3.31-mm
2
(minimum) for the low-voltage DC power supply module. Use 16-AWG or 1.31-mm
2
(minimum) for the high-voltage AC or DC power supply module.
4.
Strip each of the two wires to 0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm). Do not strip more than 0.27 inch (6.8 mm)
of insulation from the wire. Stripping more than the recommended amount of wire can leave exposed wire from the
connector after installation.
Figure 15
Stripping the Input Power Source Wire
5.
Insert the wire into a spade terminal, and crimp it to the wire. You can also use a ring or flanged spade terminal as
listed in the
“Equipment That You Need” section on page 5
.
Figure 16
Crimping the Spade Terminal Lug
6.
Loosen the terminal screw, and slide the terminal under the screw and washer. See
4
Negative connection for high-voltage DC
(PSU1)
11
Negative connection for high-voltage DC
(PSU2)
5
PSU1 (power-supply module 1)
12
PSU2 (power-supply module 2)
6
Positive connection for low-voltage DC
(PSU1)
13
Positive connection for low-voltage DC
(PSU2)
7
Negative connection for low-voltage DC
(PSU1)
14
Negative connection for low-voltage DC
(PSU2)
0.25 in. (6.3 mm) ± 0.02 in. (0.5 mm)
60531
207427