6
Step 6
On the power connector, insert the exposed part of the positive wire into
the connection labeled “+” and the exposed part of the return wire into the
connection labeled “–”. Make sure that you cannot see any wire lead. Only
wire with insulation should extend from the connector.
1 - Power source positive connection.
2 - Power source return connection.
Step 7
Use a ratcheting torque flathead screwdriver to torque the power
connector captive screws (above the installed wire leads) to 2 in-lb (0.23
N-m)
1
- Power connector captive screws
Step 8
Connect the other end of the positive wire to the positive terminal on the DC power source, and connect the other
end of the return wire to the return terminal on the DC power source.
When you are testing the device, one power connection is sufficient. If you are installing the device and are using a
second power source, repeat steps 4 through 8 using the second power connector.