Description
Command Detail
User, Admin
Access Level
All PE CA Settings:
GET "https://192.168.0.1/ws/v2/service_cfg/ca/pe"
Single PE CA Setting:
GET "https://192.168.0.1/ws/v2/service_cfg/ca/pe? peid=1&cidecrypt
GET Syntax
POST "https://192.168.0.1/ws/v2/service_cfg/pe? peid=1&cidecrypt=ON"
POST Syntax
Setting parameters using
command line arguments is
limited to maximum of 26
arguments after the ?.
URI Parameters (extension to the Command URL separated by /): N/A
These arguments are intended to be used with POST. When this command is used as a GET command
these arguments generally serve as output field descriptions.
Note
Table 204: URI Query/Set Arguments (possible fields and values preceded by ? and separated by &)
Description
URI Argument
Program Entry ID
Type: Integer
Value: 1..32
peid
Program CAM Decrypt Mode
Type: String
Value: "OFF", "ON", "Comp"
cidecrypt
CAM Slot for Program Entry 1
Type: String
Value: "TOP", "BOTTOM", "AUTO"
cipe1slot
CAM Slot for Program Entries other the PE1
Type: String
Value: "TOP", "BOTTOM"
cislot
POST Examples:
Example 1: Set various PE Setting Arguments
Cisco D9800 Network Transport Receiver Version 2.75 RESTful Web Services API Reference Guide
240
API Definitions
CA (Conditonal Access) Configuration Commands