background image

Configure SFPs  

Configure Interface Speed and Duplex Mode  

Ethernet interfaces on the switch operate at 10, 100, or 1000 Mbps, or 10,000 Mbps and in either full- or 
half-duplex mode. In full-duplex mode, two stations can send and receive traffic at the same time. 
Normally, 10-Mbps ports operate in half-duplex mode, which means that stations can either receive or 
send traffic. 

You cannot configure speed on SFP module ports, but you can configure speed to not negotiate 
(

nonegotiate

) if connected to a device that does not support autonegotiation. However, when a 

1000BASE-T SFP module is in the SFP module port, you can configure speed as 10, 100, or 1000 Mbps, 
or auto. 

You cannot configure duplex mode on SFP module ports unless a 1000BASE-T SFP module or a 
100BASE-FX MMF SFP module is in the port. All other SFP modules operate only in full-duplex mode. 

z

When a 1000BASE-T SFP module is in the SFP module port, you can configure duplex mode to 

auto

 or 

full

z

When a 100BASE-FX SFP module is in the SFP module port, you can configure duplex mode to 

half

 or 

full

Note: 

Half-duplex mode is supported on Gigabit Ethernet interfaces. However, you cannot configure these 

interfaces to operate in half-duplex mode. 

In order to display the information about an optical transceiver installed, use this command: 

show hw-

module subslot slot/subslot transceiver port idprom

Use Third Party SFP Modules  

The use of third party SFP transceivers with Cisco devices is not supported by Cisco. Cisco-approved SFP 
modules have a serial EEPROM that contains the module serial number, the vendor name and ID, a 
unique security code, and cyclic redundancy check (CRC). When an SFP module is inserted in the switch, 
the switch software reads the EEPROM to verify the serial number, vendor name and vendor ID, and 
recomputes the security code and CRC. If the serial number, the vendor name or vendor ID, the security 
code, or CRC is invalid, the software generates this security error message and places the interface in an 
error-disabled state: 

SYS-3-TRANSCEIVER_NOTAPPROVED:Transceiver on port [dec]/[dec] is not supported 

Connect a SFP Module to a GBIC Module  

The SFP and GBIC is just a connection between the actual laser and the chassis. You need to verify these 
in order to connect a SFP module with a GBIC module: 

z

The type of fiber optic cable used: Single Mode or Multi Mode. 

z

The type of physical connection required: SC connector, ST connector, etc. 

Troubleshoot SFPs  

The Link Does Not Come Up in the Sup720 Module with Line Cards WS-X6724-SFP and WS-
X6748-SFP, Even After a Reboot  

This issue is due to an Online Insertion and Removal (OIR) or a reboot that caused the port to move into 
the disabled state. This problem most likely occurs in a Supervisor 720 (Sup720) that runs Catalyst OS 
(CatOS) versions 8.4(2), 8.4(3) with line cards WS-X6724-SFP and WS-X6748-SFP. 

If the port is not in the disabled state before a reboot or OIR, the port remains in operation after the reboot. 
However, if the port is in diasbled state before or after a reboot, toggle the negotiation state of the port 
before the remote end is connected. Complete these steps in order to toggle the negotiation of the port:

1000BASE-
ZX

1550

SMF

Approximately 70 km, 
which depends on 
link loss

1000BASE-
BX-D

1310

SMF

10 km (32,8210 ft)

1000BASE-
BX-U

1490

SMF

10 km (32,8210 ft)

Содержание CWDM-SFP-1470

Страница 1: ... 3750 E Series Catalyst 3560 Series Catalyst 3560 E Series Catalyst 2970 Series Catalyst 2960 Series Catalyst 2950 Series Catalyst 2948G Series Catalyst 2940 Series Catalyst Express 500 Series Safety Guidelines Laser Safety Guidelines for Handling SFPs Required Tools Install and Remove SFP Transceiver Modules Types of SFP Transceiver Latches Install a SFP Transceiver Module Remove SFP Transceiver ...

Страница 2: ...sco Gigabit Ethernet SFP Modules Cisco 100M Ethernet SFP Part Number Description Cisco 100BASE FX SFP GLC FE 100FX Operates on ordinary multimode fiber optic MMF link spans up to 2 kilometers long For 100Mbps Ethernet ports GLC GE 100FX Operates on ordinary multimode fiber optic MMF link spans up to 2 kilometers long For Gigabit Ethernet ports Cisco 100BASE LX10 SFP GLC FE 100LX Operates on ordina...

Страница 3: ...ultimode fiber links up to 550 m and on 62 5 μm FDDI grade multimode fibers up to 220 m Cisco 1000BASE LX LH SFP GLC LH SM1 SFP GE L2 Operates on standard single mode fiber optic link spans of up to 10 km and up to 550 m on any multimode fibers Cisco 1000BASE ZX SFP GLC ZX SM1 SFP GE Z2 Operates on standard single mode fiber optic link spans of up to approximately 70 km in length Operates on a sin...

Страница 4: ...w coded CWDM SFP 1550 shown CWDM SFPs come in eight wavelengths that range from 1470 nm to 1610nm Color markings on the devices identify the wavelength to which the Gigabit Ethernet channel is mapped This table lists the SFPs with their wavelength and color codes Cisco 1000BASE BX10 D 1000BASE BX10 U SFP GLC BX D2 GLC BX U2 standard single mode fiber A 1000BASE BX10 D device is always connected to...

Страница 5: ...Channel Green CWDM SFP 1550 Cisco CWDM 1550 nm SFP Gigabit Ethernet and 1 and 2 Gb Fibre Channel Yellow CWDM SFP 1570 Cisco CWDM 1570 nm SFP Gigabit Ethernet and 1 and 2 Gb Fibre Channel Orange CWDM SFP 1590 Cisco CWDM 1590 nm SFP Gigabit Ethernet and 1 and 2 Gb Fibre Channel Red CWDM SFP 1610 Cisco CWDM 1610 nm SFP Gigabit Ethernet and 1 and 2 Gb Fibre Channel Brown Modules 100M SFPs Gigabit Ethe...

Страница 6: ...LC LH SM GLC ZX SM GLC BX D GLC BX U All CWDM SFPs Switches 100M SFPs Gigabit Ethernet SFPs CWDM SFPs WS C3750E 24TD WS C3750E 24PD WS C3750E 48TD WS C3750E 48PD WS C3750E 48PD F GLC GE 100FX GLC T GLC SX MM GLC LH SM GLC ZX SM GLC BX D GLC BX U All CWDM SFPs Switches 100M SFPs Gigabit Ethernet SFPs CWDM SFPs WS C3560 8PC GLC FE 100FX GLC FE 100LX GLC FE 100BX D GLC FE 100BX U GLC SX MM GLC LH SM ...

Страница 7: ... 100M SFPs Gigabit Ethernet SFPs CWDM SFPs WS C2960 24TC L WS C2960 48TC L WS C2960G 24TC L GLC GE 100FX GLC FE 100FX GLC FE 100LX GLC FE 100BX D GLC FE 100BX U GLC SX MM GLC LH SM GLC ZX SM GLC BX D GLC BX U All CWDM SFPs Switches 100M SFPs Gigabit Ethernet SFPs CWDM SFPs WS C2950ST 8 LRE WS C2950ST 24 LRE WS C2950ST 24 LRE997 GLC T GLC SX MM GLC LH SM GLC ZX SM All CWDM SFPs Switches 100M SFPs G...

Страница 8: ... an ESD preventive wrist strap that is connected to the chassis in order to prevent ESD damage z Cisco SFP modules are dust sensitive Always store the devices with plugs installed in the optical bores z Do not remove and insert a Cisco SFP module more often than is necessary Repeated romovals and insertions of a Cisco SFP module can shorten its useful life Required Tools You need these tools in or...

Страница 9: ...emoval procedures z SFP transceiver with a Mylar tab latch z SFP transceiver with an actuator button latch z SFP transceiver that has a bale clasp latch Install a SFP Transceiver Module Complete these steps in order to install a SFP transceiver 1 Attach an ESD preventive wrist strap to your wrist and to the ESD ground connector or a bare metal surface on your chassis 2 Remove the SFP Transceiver M...

Страница 10: ...and the transceiver optical bores until you are ready to make a connection Always inspect and clean the LC connector end faces just before you make any connections See the Required Tools section of this document for more information Always grasp the LC connector housing to plug or unplug a fiber optic cable 7 Remove the dust plugs from the network interface cable LC connectors Save the dust plugs ...

Страница 11: ...r optic cable LC connectors Tip For reattachment of fiber optic cables note which connector plug is send TX and which is receive RX 3 Release and remove the SFP Transceiver Module from the socket connector If the SFP transceiver has a Mylar tab latch pull the tab gently in a slightly downward direction until the transceiver disengages from the socket connector and then pull the SFP transceiver str...

Страница 12: ...e connectors and the minimum cable distance for all SFPs listed MMF and SMF G 652 is 2 meters 6 5 feet SFP Wavelength nm Fiber Type Cable Length GLC FE 100FX 1310 MMF 2 km 6562 ft GLC GE 100FX 1300 MMF 2 km 6562 ft GLC FE 100LX 1310 SMF 10 km 32 810 ft GLC FE 100BX U 1310 SMF 10 km 32 810 ft GLC FE 100BX D 1550 SMF 10 km 32 810 ft GLC FE 100EX 1310 SMF 40 km 131 240 ft GLC FE 100ZX 1550 SMF 80 km ...

Страница 13: ... number the vendor name and ID a unique security code and cyclic redundancy check CRC When an SFP module is inserted in the switch the switch software reads the EEPROM to verify the serial number vendor name and vendor ID and recomputes the security code and CRC If the serial number the vendor name or vendor ID the security code or CRC is invalid the software generates this security error message ...

Страница 14: ...mmand in order to hardcode the speed of the SFP port to 100Mbps Switch config if speed 100 Use the 10 Gigabit Ethernet and Gigabit Ethernet SFP Ports of a SupII 10GE or SupV 10GE in a Catalyst 4500 Series Switch Catalyst 4500 Supervisor II Plus 10GE WS X4013 10GE or Supervisor V 10GE WS X4516 10GE has four GE uplink interfaces and two 10 GE uplink interface per supervisor The tables in this sectio...

Страница 15: ... Active Active 10GE 2 2 N A Active Not Active Uplink Interface Slot 1 Supervisor II Plus 10GE or V 10 GE Slot 2 Empty Slot 1 Empty Slot2 Supervisor II Plus 10GE or V 10 GE Slot1 Supervisor II Plus 10GE or V 10 GE Slot2 Supervisor II Plus 10GE or V 10 GE GE 1 3 Active N A Active GE 1 4 Active N A Active GE 1 5 Active N A Not Active GE 1 6 Active N A Not Active GE 2 3 N A Active Active GE 2 4 N A Ac...

Страница 16: ...nvertor Mode for more information The Links Do Not Come Up in Cisco 3800 Series Routers with SPFs for Connecting to Cisco Catalyst Switches When the SFPs are used to connect a Cisco 3800 Series router to a Cisco Catalyst switch the link cannot come up and the show interface command shows down down In order to overcome this issue enable autonegotiation on both the router and switch In order to perm...

Страница 17: ...roduct Support z Cisco Transceiver Modules Product Support z Cisco Switches Product Support z LAN Product Support z LAN Switching Technology Support z Technical Support Documentation Cisco Systems GBIC AND SFP 3 years 8 months ago 3550 EMI image and SFP 3 years 3 months ago GBIC SFP new question 3 years 2 months ago what is SFP 3 years 11 months ago Jitez1234 8 Replies sjonessha 3 Replies uubozou1...

Отзывы: