background image

Chapter 2      Cabling the CSS

Connecting the Console to the CSS

2-32

Cisco 11000 Series Content Services Switch Hardware Installation Guide

78-15146-02

2.

Using a flat-head screwdriver, loosen the captive screws on the three DC 
connectors (labeled from left to right, +, –, and

, respectively). 

Warning

Before installing a wire, ensure that the polarity of the DC connections is 
correct. Reversed polarity can cause damage to the DC power supply and can 
create a dangerous shock hazard.

3.

Install the wires into the appropriate connector. Make sure that the 
uninsulated part of each wire is 9mm (0.35 in.) in length. 

When installing the wires, always connect the ground wire first. When 
disconnecting the wires, always disconnect the ground wire last.

The proper power cable wiring between the CSS 11800 and DC power source 
is illustrated in 

Table 2-11

.

4.

Tighten the captive screws to 5 to 7 inch-pounds (.6 to .8 Nm) of torque to 
secure the wires in the connectors. Ensure the wires are held firmly in place.

Connecting the Console to the CSS

To connect a console to the CSS, attach the console cable (provided in the 
accessory kit) to the Console port on the CSS 11050 or CSS 11150 front panel, or 
to the CSS 11800 SCM panel. Your terminal settings must match the following 
CSS default settings:

Baud Rate: 9600

Data Bits: 8

Flow Control: none

59199

Table 2-11

CSS 11800 to DC Power Source Cabling

CSS 11800

DC Power Source

  

(Ground) 

 

 (Ground)

+

+

59199

59199

Содержание CSS-11154-256M-AC - 1000Mbps Ethernet Switch

Страница 1: ... San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 526 4100 Cisco 11000 Series Content Services Switch Hardware Installation Guide Software Version 6 10 July 2003 Text Part Number 78 15146 02 Customer Order Number DOC 7815146 ...

Страница 2: ...difying the equipment without Cisco s written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital devices In that event your right to use the equipment may be limited by FCC regulations and you may be required to correct any interference to radio or television communications at your own expense You can determine whether your equipment ...

Страница 3: ...ogo Empowering the Internet Generation Enterprise Solver EtherChannel EtherSwitch Fast Step GigaStack Internet Quotient IOS IP TV iQ Expertise the iQ logo iQ Net Readiness Scorecard LightStream MGX MICA the Networkers logo Networking Academy Network Registrar Packet PIX Post Routing Pre Routing RateMUX Registrar ScriptShare SlideCast SMARTnet StrataView Plus Stratm SwitchProbe TeleRouter The Faste...

Страница 4: ......

Страница 5: ... Ordering Documentation xxi Documentation Feedback xxi Obtaining Technical Assistance xxii Cisco com xxii Technical Assistance Center xxii Cisco TAC Website xxiii Cisco TAC Escalation Center xxiv Obtaining Additional Publications and Information xxiv C H A P T E R 1 Unpacking and Installing the CSS 1 1 Site Requirements 1 2 Required Tools and Equipment 1 2 Shipment Contents 1 2 Unpacking the CSS 1...

Страница 6: ...assis 1 13 Installing a CSS 11800 Module 1 14 Installation Precautions and Restrictions 1 14 Installation Precautions 1 14 Module Slot Restrictions 1 15 Removing or Installing a Module 1 17 Unpacking a CSS 11800 Module 1 17 Installing a Module 1 18 Installing a Passive SCM or SFM 1 20 Passive Module Switchover 1 21 C H A P T E R 2 Cabling the CSS 2 1 Cabling the CSS 11050 and CSS 11150 2 1 CSS 110...

Страница 7: ...ng Power Cords 2 26 Connecting a CSS 11050 or CSS 11150 Power Cord 2 26 Connecting a CSS 11050 or CSS 11150 AC Power Cord 2 27 Connecting a CSS 11150 DC Power Cord 2 27 Connecting a CSS 11800 Power Cord 2 29 Connecting a CSS 11800 AC Power Cord 2 30 Connecting a CSS 11800 DC Power Cord 2 30 Connecting the Console to the CSS 2 32 Powering Up the CSS 2 34 Powering Down the CSS 2 34 Troubleshooting C...

Страница 8: ... Management A 9 DC Power Supply Safety Warnings A 9 Lithium Battery Disposal Warnings A 10 A P P E N D I X B Cable Pinouts B 1 RJ 45 Fast Ethernet Connector Pinouts B 2 RJ 45 RS 232 Serial Connector Pinouts B 3 RJ 45 to RJ 45 CSS Cisco Console Adapter Cable B 5 Custom Cable Pinouts for Attaching the CSS Console Port to a Communication Server B 6 RJ 45 Timing BITS Connector Pinouts B 8 RJ 45 Manage...

Страница 9: ...Requirements C 4 Radio Frequency Interference C 5 If Problems Arise C 5 Korean Class A EMC Warning C 6 Korean Certification Information C 6 Declaration of Conformity with Regard to the Directives 73 23 EEC and 89 336 EEC as amended by Directive 93 68 EEC C 8 Class A Warning for Taiwan and Other Traditional Chinese Markets C 9 I N D E X ...

Страница 10: ...Contents x Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 ...

Страница 11: ...tent Services Switch 2 2 Figure 2 2 CSS 11050 and CSS 11150 Rear Panel Connectors and LEDs 2 3 Figure 2 3 CSS 11051 Front Panel Connectors and LEDs 2 4 Figure 2 4 CSS 11052 Front Panel Connectors and LEDs 2 4 Figure 2 5 CSS 11151 Front Panel Connectors and LEDs 2 6 Figure 2 6 CSS 11152 Front Panel Connectors and LEDs 2 6 Figure 2 7 CSS 11153 Front Panel Connectors and LEDs 2 7 Figure 2 8 CSS 11154...

Страница 12: ... 2 16 Internal Disk Module LEDs 2 25 Figure 2 17 Connecting a CSS 11050 or CSS 11150 AC Power Cord 2 27 Figure 2 18 Location of CSS 11150 DC Power Supply Connectors 2 28 Figure 2 19 Connecting a CSS 11800 AC Power Cord 2 30 Figure 2 20 Location of CSS 11800 DC Power Supply Connectors 2 31 Figure 2 21 Attaching Ferrites to a CSS 11050 or 11150 Console Cable 2 33 ...

Страница 13: ...tch Fabric Module LED Descriptions 2 24 Table 2 9 CSS 11800 Internal Disk Module LED Descriptions 2 26 Table 2 10 CSS 11150 to DC Power Source Cabling 2 29 Table 2 11 CSS 11800 to DC Power Source Cabling 2 32 Table 2 12 Troubleshooting the Console Interface 2 35 Table 2 13 Troubleshooting the CSS 11050 or CSS 11150 CSS Power Supply 2 36 Table 2 14 Troubleshooting the CSS 11800 Power Supply 2 36 Ta...

Страница 14: ...ial Connector Pinouts for the Diag Port B 4 Table B 5 RJ 45 RS 232 Serial Connector Pinouts for the SFM2 Diag1 and Diag2 Port B 4 Table B 6 RJ 45 to RJ 45 Cisco Console Adapter Cable Pinouts B 5 Table B 7 CSS RJ 45 RS 232 Console Port Adapter Cable Pinouts Cable Not Reversible B 7 Table B 8 CSS RJ 45 RS 232 Console Port Full Cable Pinouts Cable Reversible B 7 Table B 9 RJ 45 Timing BITS Connector ...

Страница 15: ...50 CSS 11150 and CSS 11800 It provides you with instructions for installing cabling booting and configuring the CSS Information in this guide applies to all CSSs except where noted This preface describes the following topics Audience How to Use This Guide Related Documentation Symbols and Conventions Obtaining Documentation Obtaining Technical Assistance Obtaining Additional Publications and Infor...

Страница 16: ...es the contents of each chapter and appendix Chapter Appendix Description Chapter 1 Unpacking and Installing the CSS Provides instructions for unpacking and installing the CSS Chapter 2 Cabling the CSS Provides instructions for cabling the CSS and the CSS 11800 modules and describes the CSS LEDs and connectors This chapter also provides instructions for connecting the console powering the CSS and ...

Страница 17: ...ion on operating considerations caveats and CLI commands for the Cisco 11000 series CSS Cisco Content Services Switch Administration Guide Describes how to perform administration tasks on the CSS including logging into the CSS upgrading your CSS software and configuring the following Management ports interfaces and circuits DNS ARP RIP IP and bridging features OSPF Logging including displaying log...

Страница 18: ...ce Locator Qualifier Lists URQLs Network Qualifier Lists NQLs and Domain Qualifier Lists DQLs Caching Cisco Content Services Switch Advanced Configuration Guide Describes how to perform advanced CSS configuration tasks including Domain Name Service DNS DNS Sticky Content Routing Agent Client Side Accelerator Network proximity VIP and virtual IP interface redundancy Box to box redundancy Demand bas...

Страница 19: ... appears in a command line including the CLI prompt Courier bold text indicates commands and text you enter in a command line Italics text indicates the first occurrence of a new term book title emphasized text and variables for which you supply values 1 A numbered list indicates that the order of the list items is important a An alphabetical list indicates that the order of the secondary list ite...

Страница 20: ...w cisco com univercd home home htm You can access the Cisco website at this URL http www cisco com International Cisco websites can be accessed from this URL http www cisco com public countries_languages shtml Documentation CD ROM Cisco documentation and additional literature are available in a Cisco Documentation CD ROM package which may have shipped with your product The Documentation CD ROM is ...

Страница 21: ...arketPlace http www cisco com en US partner ordering index shtml Nonregistered Cisco com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters California U S A at 408 526 7208 or elsewhere in North America by calling 800 553 NETS 6387 Documentation Feedback You can submit comments electronically on Cisco com On the Cisco Documentation ...

Страница 22: ...ms and resources at any time from anywhere in the world Cisco com provides a broad range of features and services to help you with these tasks Streamline business processes and improve productivity Resolve technical issues with online support Download and test software packages Order Cisco learning materials and merchandise Register for online skill assessment training and certification programs T...

Страница 23: ... existing network is down or there is a critical impact to your business operations You and Cisco will commit all necessary resources around the clock to resolve the situation Cisco TAC Website The Cisco TAC website provides online documents and tools to help troubleshoot and resolve technical issues with Cisco products and technologies To access the Cisco TAC website go to this URL http www cisco...

Страница 24: ...ample SMARTnet SMARTnet Onsite or Network Supported Accounts NSA When you call the center please have available your service agreement number and your product serial number Obtaining Additional Publications and Information Information about Cisco products technologies and network solutions is available from various online and printed sources The Cisco Product Catalog describes the networking produ...

Страница 25: ...et magazine at this URL http www cisco com go packet iQ Magazine is the Cisco bimonthly publication that delivers the latest information about Internet business strategies for executives You can access iQ Magazine at this URL http www cisco com go iqmagazine Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing developing an...

Страница 26: ...Preface Obtaining Additional Publications and Information xxvi Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 ...

Страница 27: ...ding or rack mount units This chapter contains the following major sections Site Requirements Shipment Contents Unpacking the CSS If the Product is Damaged Installing the CSS 11050 or CSS 11150 Installing the CSS 11800 Installing a CSS 11800 Module Note For information on installing a replacement or accessory item in the CSS 11800 such as a redundant AC or DC power supply or fan unit consult the r...

Страница 28: ...equired Tools and Equipment To install the CSS hardware you need the following tools and equipment A Phillips and a flat head screwdriver Anti static wrist strap included in the CSS 11800 accessory kit Hand lift recommended for lifting the CSS 11800 chassis into the equipment rack Once you complete the installation you need a console terminal or equivalent that runs at 9600 bps to issue console co...

Страница 29: ...e If you cannot locate the Standard software license key or a license key Claim Certificate in the Accessory kit call the Cisco Technical Assistance Center TAC toll free 24 hours a day 7 days a week at 1 800 553 2447 or 1 408 526 7209 You can also e mail TAC at tac cisco com Cisco 11000 Series Content Services Switch Hardware Installation Guide Unpacking the CSS The CSS is shipped in a protective ...

Страница 30: ...e CSS 11800 The CSS 11800 is shipped attached to a wooden pallet with screws and shipping brackets Due to the large size and weight of a unit move it to the installation site before unpacking it from the shipping carton To unpack the CSS 11800 1 Remove all enclosed packing materials Save the packing materials in case you need to repack the CSS later 2 Remove the accessories from the shipping carto...

Страница 31: ... To install the CSS go to the Installing the CSS 11800 section If the Product is Damaged If any portion of the unit or component is damaged in transit forward an immediate request to the delivering carrier to perform an inspection of the product and to prepare a damage report Save the container and all packing materials until the contents are verified Shipping brackets Shipping brackets 49566 ...

Страница 32: ...bserve the following installation requirements The ambient operating temperature is 32 to 104 F 0 to 40 C If you install the CSS in a closed or multi unit rack the operating ambient temperature of the rack environment may be greater than the room ambient temperature Ensure that the temperature does not exceed the CSS maximum ambient operating temperature The minimum clearance requirement is 2 inch...

Страница 33: ... even with the front edge of the rack Mid mounting the CSS sets the front edge of the unit past the front edge of the rack Install the mounting brackets on the CSS The rack position of the CSS determines where you will install the mounting brackets on the CSS chassis See the following section to install the mounting brackets Installing the Mounting Brackets Before you begin you will need the mount...

Страница 34: ...e CSS with four screws 4 Repeat steps 2 and 3 to install a mounting bracket on the other side of the CSS You are ready to install the CSS in the cabinet Installing the CSS into the Rack Before you begin you will need a 2 Phillips screwdriver and four pan head screws To install the CSS 11050 or CSS 11150 into an equipment rack 1 Raise the CSS to the installation height Align the screw holes on the ...

Страница 35: ...extension cords to connect the CSS to the power source Before you rack mount the CSS 11800 chassis determine if you want to front mount mid mount or extend mount the chassis in the cabinet Front mount the chassis to set the front edge of the unit even with the front edge of the rack The brackets are preinstalled in this position on the chassis and are ready for mounting in a rack as described in t...

Страница 36: ... on the CSS 11800 for Mid Mounting 3 Using a Phillips screwdriver install only five of the seven 10 32 pan head screws through the mid mount bracket holes into the CSS Do not install the screws in the top of the bracket or second from the bottom of the bracket 4 Repeat steps 1 through 3 to install the second bracket onto the other side of the chassis When the brackets are in position for mounting ...

Страница 37: ...s you use to install the brackets to the chassis determines how the chassis is mounted in a rack The screw holes toward the front of the bracket position each bracket on the CSS 11800 chassis for front mounting in a cabinet this is the preinstalled position The screw holes behind the first set of holes position each bracket on the CSS 11800 chassis for extended mounting in a cabinet Figure 1 5 ill...

Страница 38: ... one side of the chassis 2 Align the rear screw holes on the bracket with the screw holes on the front side of the chassis Note the bracket s proper orientation as shown in Figure 1 6 Figure 1 6 Aligning Brackets on the CSS 11800 Chassis for Extended Mounting 3 Using a Phillips screwdriver install the seven 10 32 pan head screws through the extended mount bracket holes into the CSS 4 Repeat steps ...

Страница 39: ...chassis into a cabinet 1 Locate the mounting keys on the left and right mounting brackets see Figure 1 4 Mounting keys are designed to fit over pan head screws installed in the mounting rack to hold the chassis in place while you secure the chassis into the rack 2 Install a pan head screw into the left and right sides of the mounting rack These screws fit into the mounting keys and hold the chassi...

Страница 40: ...s recommended that you read the topics in this section before installing a module Installation Precautions Read and observe the following precautionary information prior to servicing the CSS 11800 Warning Do not remove or install modules without using appropriate anti static guard measures The CSS includes an anti static wrist strap in the accessory kit Attach the copper tape end of the strap to a...

Страница 41: ...ackplane connector for slot 2 does not accommodate a SCM connector Prior to installing a module see Table 1 1 for information on chassis slot usage Table 1 1 Chassis Slot Usage Slot Number Slot Usage Slot Color Code 1 I O Module Blue 2 I O Module Blue 3 I O Module Blue 4 I O Module Blue 5 SFM or SFM2 passive module Purple 6 SFM or SFM2 active module Purple 7 SCM initial active module Red 8 SCM ini...

Страница 42: ...the CSS Installing a CSS 11800 Module 1 16 Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 Figure 1 7 illustrates a fully configured CSS 11800 Figure 1 7 Fully Configured CSS 11800 49572 Slot 1 Slot 15 ...

Страница 43: ...for the module For information on image and configuration files refer to the Content Services Switch Administration Guide The newly installed module boots up with The appropriate module image The same configuration as the former module When you remove a module and replace it with a module of a different type the SCM downloads the module boot image automatically The newly installed module boots up ...

Страница 44: ...ng a Passive SCM or SFM section For information on removing and replacing a module see the Removing or Installing a Module section To install a module 1 Properly ground yourself prior to handling the module For example wear the anti static wrist strap included in the accessory kit and stick the copper tape end of the strap to an unpainted metal surface on the chassis Make sure that the wrist strap...

Страница 45: ...8 Figure 1 8 Installing a Module into a CSS 11800 Chassis 4 Close both ejectors simultaneously to seat the module connector into the backplane 5 Using a Phillips screwdriver tighten the spring loaded screws on the front of the module faceplate Once you install the module it begins diagnostics and initializes automatically If you installed a SFM or SFM2 you must reboot the chassis to activate it 6 ...

Страница 46: ...eries may never be disposed of in an unregulated fire Other restrictions might apply See Appendix A Specifications for lithium battery disposal warnings Warning Ultimate disposal of a lithium battery should be handled according to all national laws and regulations The CSS 11800 enables you to install a passive SCM for the active SCM SFM for each of the two active SFMs total of four SFMs Note You c...

Страница 47: ...ly To power on the SFM or SFM2 reboot the CSS 8 Power up the CSS 9 To copy the boot configuration from the active SCM to the passive SCM use the passive sync command in boot configuration mode Passive Module Switchover If the active SCM fails 1 The CSS reboots and connections are terminated 2 The CSS restores all configurations using the startup config file 3 The passive SCM becomes active automat...

Страница 48: ...Chapter 1 Unpacking and Installing the CSS Installing a CSS 11800 Module 1 22 Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 ...

Страница 49: ...ept where noted This chapter contains the following major sections Cabling the CSS 11050 and CSS 11150 Cabling the CSS 11800 Modules Connecting Power Cords Connecting the Console to the CSS Powering Up the CSS Powering Down the CSS Troubleshooting CSS Hardware Components Cabling the CSS 11050 and CSS 11150 The CSS 11050 and CSS 11150 are fixed configuration devices designed for small Web sites or ...

Страница 50: ...aces Optional integrated Gigabit Ethernet Network Interface Card GENIC with one uplink port The CSS 11150 configuration supports 12 auto sensing 10 100 Mbps Ethernet 10BASE T 100BASE TX interfaces Optional integrated Gigabit Ethernet Network Interface Card GENIC with two GBIC ports in either 4 MB or 8 MB per port versions Optional integrated Fast Ethernet Network Interface Card FENIC with four SC ...

Страница 51: ...ink Activity 10 100 Mbps and Duplex Half or Full LEDs as shown in Figure 2 2 Figure 2 2 CSS 11050 and CSS 11150 Rear Panel Connectors and LEDs Table 2 1 describes the LEDs on the rear panel Power switch AC connector Ethernet management port Management Link Act Duplex 10 100 10 100 Ethernet 49575 Table 2 1 CSS 11050 and CSS 11150 Ethernet Management Port LED Descriptions LED Name Color State Indica...

Страница 52: ...11051 Front Panel Connectors and LEDs The CSS 11052 shown in Figure 2 4 also has one Gigabit Ethernet connection using a Gigabit Interface Converter GBIC and associated Transmit Receive and Link LEDs The GBIC complies with Revision 5 1 of the GBIC specification for Class 4 GBICs The GBIC network interface complies with the IEEE 1000BASE SX specification for short laser wavelength of 850 nm and use...

Страница 53: ...rating at 100 Mbps Power Green Off CSS does not have power On CSS has power Status Yellow Off CSS is operational Blinking CSS detects an error during offline or online testing or the boot diagnostic failed and the system cannot boot Ready Green Off CSS is booting On CSS is operational Blinking CSS is accessing the disk Tx Transmit Gigabit port on the CSS 11052 Green Off No transmit packet activity...

Страница 54: ...s 10 100 Mbps and Duplex Half or Full LEDs Power Status and Ready LEDs Figure 2 5 CSS 11151 Front Panel Connectors and LEDs The CSS 11152 shown in Figure 2 6 has four additional Fast Ethernet TX connectors and their associated Link Activity status 10 100 Mbps and Duplex Half or Full LEDs Figure 2 6 CSS 11152 Front Panel Connectors and LEDs Power Status Ready 1 2 3 4 5 6 7 8 9 101112 2X 4X 6X 8X 10...

Страница 55: ...k interfaces comply with the IEEE 1000BASE SX specification for short laser wavelength of 850 nm and use SC type fiber connectors Figure 2 8 CSS 11154 Front Panel Connectors and LEDs Note The CSS 11155 has a similar appearance to the CSS 11154 but its memory size per port is 8 MB instead of 4 MB Power Status Ready 1 2 3 4 5 6 7 8 9 101112 13141516 2X 4X 6X 8X 10X 12X 13X 14X 15X 16X 1X 3X 5X 7X 9X...

Страница 56: ...x 10 100 Fast Ethernet TX ports Green Off Port is operating at 10 Mbps On Port is operating at 100 Mbps Power Green Off CSS does not have power On CSS has power Status Yellow Off CSS is operational Blinking CSS detects an error during offline or online testing or the boot diagnostic failed and the system cannot boot Ready Green Off CSS is booting On CSS is operational Blinking CSS is accessing the...

Страница 57: ...ectors and LEDs Gigabit Ethernet Module Connectors and LEDs Switch Fabric Module SFM and SFM2 Connectors and LEDs Internal Disk Module LEDs Link Sync Gigabit ports on the CSS 11154 or CSS 11155 Green Off No link On Link exists and synchronization achieved Blinking Link exists but not synchronized Link Fast Ethernet FX ports on the CSS 11153 Green Off No link established On Link established Act Fas...

Страница 58: ...rt for an optional redundant 20 Gbps switch fabric 128 MB Switch Control Module SCM model CSS8 SCM with support for an optional passive SCM 10 Gbps Switch Fabric Module 2 SFM2 model CSS8 SFM2 with support for an optional passive SCM2 Hard drive based Internal Disk Module IDM model CSS8 IDM MEM HD for logging and off line system files Eight slots configurable with either Fast Ethernet modules provi...

Страница 59: ...00 Series Content Services Switch Hardware Installation Guide 78 15146 02 Chapter 2 Cabling the CSS Cabling the CSS 11800 Modules Figure 2 9 illustrates a CSS 11800 Figure 2 9 CSS 11800 Content Services Switch 49582 ...

Страница 60: ...nd configure a passive SCM for redundancy A maximum of two SCMs are allowed in a chassis Note The SCM contains a small lithium battery Some jurisdictions restrict the ways in which items containing lithium batteries may be disposed In particular lithium batteries or products containing lithium batteries may never be disposed of in an unregulated fire Other restrictions might apply See Appendix A S...

Страница 61: ...ctive module LEDs Duplex 10 100 and Active LEDs for the Fast Ethernet port Power Supply 1 and 2 LEDs Figure 2 10 illustrates the SCM front panel connectors and LEDs Figure 2 10 Switch Control Module Connectors and LEDs 49583 Power LED Status LED Active LED 10 100 Ethernet connector Console connector Diag connector Timing BITS connector Power supply 1 LED Module ejector Power supply 2 LED Duplex LE...

Страница 62: ... On Module is experiencing an error only when the SCM is active the LED is normally yellow when the SCM is passive Active Green Off SCM is passive On SCM is active Duplex Ethernet Management Port Green Off Port is operating at half duplex On Port is operating at full duplex 10 100 Ethernet Management Port Green Off Port is operating at 10 Mbps On Port is operating at 100 Mbps Link Ethernet Managem...

Страница 63: ...t settings as specified in Table 2 5 Fast Ethernet Module Connectors and LEDs The FEM is available in two models Model CSS8 IOM 8FE contains eight auto sensing RJ 45 Fast Ethernet 10 100 Mbps 10BASE T 100BASE TX connectors Model CSS8 IOM 6 2FE contains six auto sensing RJ 45 Fast Ethernet 10 100 Mbps 10BASE T 100BASE TX connectors and two 100BASE FX SC fiber connectors Table 2 5 CSS Console Port D...

Страница 64: ...r Status and Ready LEDs for module status and Duplex Speed and Link LEDs for each of the eight connectors Figure 2 11 illustrates the LEDs and connectors on the 8 port FEM Figure 2 11 8 Port Fast Ethernet Module Connectors and LEDs 49584 Power LED Status LED Ready LED Module ejector Module ejector 10 100 LEDs RJ 45 10BASE T 100BASE TX connectors Link LEDs Duplex LEDs ...

Страница 65: ...re 2 12 illustrates the LEDs and connectors on the FEM model CSS8 IOM 6 2 FE Figure 2 12 Fast Ethernet Module with 6 10BASE T 100BASE TX Connectors Two 100BASE FX SC Fiber Connectors and LEDs 49585 Power LED Status LED Ready LED Module ejector Module ejector 10 100 LEDs RJ 45 10BASE T 100BASE TX connectors Fiber SC connectors Link LEDs Duplex LEDs ...

Страница 66: ... contains four GBIC slots and 16 MB Flow Cache SRAM memory supporting up to 128 000 simultaneous flows CSS8 GBIC SX is sold separately Table 2 6 Fast Ethernet Module LED Descriptions LED Name Color LED Status Indicates Power Green Off Module does not have power On Module has power Status Yellow Off Module is operational On Module is experiencing an error Ready Green Off Module not initialized On M...

Страница 67: ...2 13 illustrates the LEDs and connectors on a GEM Figure 2 13 Gigabit Ethernet Module Connectors and LEDs 1 2 3 4 49586 Power LED Status LED Ready LED Gigabit interface converter GBIC SC fiber connectors top receive bottom transmit Module ejector Module ejector Ports 2 through 4 for additional GBIC connectors Receive LEDs Link sync LEDs Transmit LEDs ...

Страница 68: ...odule LED Descriptions LED Name Color LED Status Indicates Power Green Off Module does not have power On Module has power Status Yellow Off Module is operational On Module is experiencing an error Ready Green Off Module not initialized On Module initialized and ready Tx Transmit Ports 1 to 4 Green Off No transmit packet activity Blinking Transmit activity detected Rx Receive Ports 1 to 4 Green Off...

Страница 69: ...les You can install a second active module to service four additional I O modules Both active modules are on simultaneously in the CSS 11800 The chassis enables you to configure two additional passive modules for redundancy Therefore you can configure a total of four SFMs or SFM2s in a chassis of which only two would be active at any time Note When the CSS 11800 contains two passive SFMs and an ac...

Страница 70: ...ont panel LEDs and connectors Figure 2 14 Switch Fabric Module Connectors and LEDs The SFM2 contains two RJ 45 RS 232 Diag1 and Diag 2 connectors combining both Console and Diag functions on each connector all of these connectors are reserved for field service diagnostic use only 49587 Power LED Status LED Active LED Debug console and diag console Module ejector Module ejector ...

Страница 71: ... connectors are for serial data only and are not compatible with Ethernet RJ 45 cable connectors Figure 2 15 illustrates the SFM2 model CSS8 SFM2 front panel LEDs and connectors Figure 2 15 Switch Fabric Module 2 Connectors and LEDs Diag 1 Diag 2 49588 Power LED Status LED Active LED Console diag connectors Diag 1 and Diag 2 Module ejector Module ejector ...

Страница 72: ...ontains Power Status and Active LEDs Figure 2 16 illustrates the IDM front panel LEDs The LEDs apply to both the flash based model CSS8 IDM MEM FD or hard drive based model CSS8 IDM MEM HD IDM Table 2 8 Switch Fabric Module LED Descriptions LED Name Color LED Status Indicates Power Green Off Module does not have power On Module has power Status Yellow Off Module is operational On Module is experie...

Страница 73: ...Content Services Switch Hardware Installation Guide 78 15146 02 Chapter 2 Cabling the CSS Cabling the CSS 11800 Modules Figure 2 16 Internal Disk Module LEDs 49589 Power LED Status LED Active LED Module ejector Module ejector ...

Страница 74: ...d Appendix A Specifications for electrical specifications The following sections describe Connecting a CSS 11050 or CSS 11150 Power Cord Connecting a CSS 11800 Power Cord Connecting a CSS 11050 or CSS 11150 Power Cord The following sections provide information on Connecting a CSS 11050 or CSS 11150 AC Power Cord Connecting a CSS 11150 DC Power Cord Note The CSS 11050 is only available in an AC ver...

Страница 75: ...n Figure 2 17 Figure 2 17 Connecting a CSS 11050 or CSS 11150 AC Power Cord 3 Plug the power cord into a dedicated 3 wire grounding receptacle 4 Switch on the power on the CSS Connecting a CSS 11150 DC Power Cord Before you install a DC power cord see Appendix A Specifications for DC power supply safety warnings Warning The DC power supply cord requires 18 AWG wire The CSS 11150 draws a maximum of...

Страница 76: ...SS 11150 DC power supply to a power source 1 Locate the DC terminal block on the front of the chassis as shown in Figure 2 18 Figure 2 18 Location of CSS 11150 DC Power Supply Connectors 2 Using a flat head screwdriver loosen the captive screws on the three DC connectors labeled from left to right and respectively Warning Before installing a wire ensure that the polarity of the DC connections is c...

Страница 77: ...he proper power cable wiring between the CSS 11150 and DC power source is illustrated in Table 2 10 4 Tighten the captive screws to 5 to 7 inch pounds 6 to 8 Nm of torque to secure the wires in the connectors Ensure the wires are held firmly in place Connecting a CSS 11800 Power Cord The following sections provide information for connecting an AC or DC power cord to a CSS 11800 Note For informatio...

Страница 78: ...ctor into the power receptacle at the front of the chassis as shown in Figure 2 19 Figure 2 19 Connecting a CSS 11800 AC Power Cord 3 Plug the power cord into a dedicated 3 wire grounding receptacle 4 Switch on the power on the CSS Connecting a CSS 11800 DC Power Cord Before you install a DC power cord see Appendix A Specifications for DC power supply safety warnings Warning The DC power supply co...

Страница 79: ...ircuit breaker Warning Before performing the DC installation procedure ensure that power is removed from the DC circuit To ensure that all power is off locate the circuit breaker that services the DC circuit and switch it off To connect the CSS 11800 DC power supply to a power source 1 Locate the DC terminal block on the front of the chassis as shown in Figure 2 20 Figure 2 20 Location of CSS 1180...

Страница 80: ...ling the wires always connect the ground wire first When disconnecting the wires always disconnect the ground wire last The proper power cable wiring between the CSS 11800 and DC power source is illustrated in Table 2 11 4 Tighten the captive screws to 5 to 7 inch pounds 6 to 8 Nm of torque to secure the wires in the connectors Ensure the wires are held firmly in place Connecting the Console to th...

Страница 81: ...ites provided in the Accessory kit The ferrites guarantee proper console operation To attach the snap on ferrites see Figure 2 21 1 Position and attach the first ferrite 75 inches from the RJ 45 connector to the Console port 2 Attach the second ferrite behind the first ferrite Figure 2 21 Attaching Ferrites to a CSS 11050 or 11150 Console Cable 59685 CONSOLE Snap on ferrite one of two 75 inch spac...

Страница 82: ...on concerning the boot process on an 11000 series CSS refer to the Content Services Switch Administration Guide For general hardware troubleshooting information see the following section Powering Down the CSS To shutdown a CSS gracefully and avoid introducing lost or fragmented files always use the shutdown command prior to removing power from the CSS This command is available in boot mode For exa...

Страница 83: ...le pinouts see Appendix B Cable Pinouts Table 2 12 Troubleshooting the Console Interface Possible Problem Recommended Action Nothing appears on the screen Ensure the RS 232 cable is securely connected to the console port Characters appear on the screen but are garbled Verify that the CSS and the console settings match for baud rate data bits stop bits and parity Abbreviated input is used but press...

Страница 84: ...plies AC or DC The power supply status LED is on the SCM Table 2 13 Troubleshooting the CSS 11050 or CSS 11150 CSS Power Supply LED Name LED Status Possible Problem Recommended Action Power Off No power to power supply Ensure unit has power Check power switch power cord and power source Fault in power supply Replace unit Table 2 14 Troubleshooting the CSS 11800 Power Supply LED Name LED Status Pos...

Страница 85: ...tion If the module detects that its temperature is out of range it generates a log message Module status is indicated by the Status LED on the module front panel For information about the module LEDs see the module information earlier in this chapter Table 2 15 provides suggestions for correcting problems that may occur with the modules Table 2 15 Troubleshooting the CSS 11800 Modules Symptom Reco...

Страница 86: ...nector Replacement IDM does not initialize If the replacement IDM does not contain the same version of the software that the CSS is currently running the SCM will not initialize the IDM for use You must reboot the CSS and configure a primary boot record You can select the CSS software currently on the disk or instruct the CSS where to locate the CSS software ADI file to install on the disk If you ...

Страница 87: ...wing major sections that list specifications for the Cisco 11000 Series Content Services Switches CSS 11050 CSS 11150 and CSS 11800 Electrical Specifications Environmental Specifications Physical Specifications Module Specifications Internal Disk Module Specifications Supported Protocols DC Power Supply Safety Warnings Lithium Battery Disposal Warnings ...

Страница 88: ...ns Note The specification for the CSS 11800 is for the system not per power supply Table A 1 AC Electrical Specification AC Specification CSS 11050 or CSS 11150 CSS 11800 Input Voltage AC 100 to 240 VAC 50 to 60 Hz 100 to 240 VAC 50 to 60 Hz Current AC max 100VAC 3 1 Amps 12 Amps Power Consumption maximum 310 Watts 1200 Watts Heat Dissipation 683 BTU hr 3073 BTU hr Table A 2 DC Electrical Specific...

Страница 89: ...ia AS 3112 1981 10A 240 VAC Austria CEE7 Sht V11 16A 240 VAC Belgium CEE7 Sht V11 16A 240 VAC British BS 1363A 13A 250 VAC Canada NEMA 5 15P 12A 125 VAC China AS 3112 1981 10A 240 VAC Denmark SRAF 1962 DB 16 87 10A 250 VAC Finland CEE7 Sht V11 16A 240 VAC France CEE7 Sht V11 16A 240 VAC Germany CEE7 Sht V11 16A 240 VAC India BS 546A 16A 250 VAC Israel S I 32 16A 250 VAC Italy CEI 23 16 10A 250 VAC...

Страница 90: ...onmental Specifications Specification CSS 11050 or CSS 11150 CSS 11800 Ambient Operating Temperature 32 to 104 F 0 to 40 C Relative Humidity 5 to 95 non condensing Ambient Storage Temperature 23 to 149 F 5 to 65 C Table A 5 Physical Specifications Specification CSS 11050 or CSS 11150 CSS 11800 Chassis Dimensions H x W x D 2 62 x 17 1 x 15 25 25 x 17 1 x 12 5 Chassis Shipping Weight 23 lbs 105 lbs ...

Страница 91: ...00 Slot Configuration Fixed configuration 8 slots for I O modules 2 slots for SCMs 1 active 1 passive 4 slots for SFMs or SFM2s 2 active 2 passive 1 slot for the IDM Switch Bandwidth 5 GB 20 GB base 20 GB 1 1 optional redundancy CPU Memory DRAM CSS 11050 128 MB CSS 11150 128 MB base with a maximum of 256 MB Switch Control Module 128 MB Switch Fabric Module SFM or SFM2 256 MB 128 MB per Switch Fabr...

Страница 92: ... for the Internal Disk Module IDM Power General IDM Power Requirements Table A 7 describes the IDM power requirements IDM General Specifications Table A 8 defines IDM general specifications Table A 7 IDM Power Requirements Power Requirements Internal Disk Module 12V 5 1 2 Amps Max 5V 5 5 Amps Max Table A 8 IDM General Specifications Specification Hard Disk Flash Disk Capacity 1 08 GB minimum 350 M...

Страница 93: ...pported Protocols The CSS supports the following protocols Transport Network Routing Gateway Application Network Utilities Network Management Transport The CSS supports the following transport protocols TCP UDP Network The CSS supports the following network protocols Internet Protocol IP ICMP Address Resolution Protocol ARP Inverse ARP ...

Страница 94: ...llowing routing protocols RIP I RIP II OSPF Version 2 Gateway The CSS supports Network Address Translation NAT per RFC 1631 gateway protocol Application The CSS supports the following application protocols HTTP 1 0 HTTP 1 1 TELNET FTP TFTP RTP Network Utilities The CSS supports the following network utility protocols DNS Client Radius Client HTTP Client FTP Daemon ...

Страница 95: ...conductor of the DC supply circuit to the grounding conductor at the equipment If this connection is made all of the following conditions must be met This equipment shall be connected directly to the DC supply system grounding electrode conductor or bonding jumper from a grounding terminal bar or bus to which the DC supply system grounding electrode conductor is connected This equipment shall be l...

Страница 96: ...her restrictions might apply Warning Ultimate disposal of this product should be handled according to all national laws and regulations Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te worden afgedankt Varoitus Tämän tuotteen lopullisesta hävittämisestä tulee huolehtia kaikkia valtakunnallisia lakeja ja säännöksiä noudattaen Attention La mise au rebut définitive de...

Страница 97: ... Warnings Aviso A descartagem final deste produto deverá ser efectuada de acordo com os regulamentos e a legislação nacional Advertencia El desecho final de este producto debe realizarse según todas las leyes y regulaciones nacionales Varning Slutlig kassering av denna produkt bör skötas i enlighet med landets alla lagar och föreskrifter ...

Страница 98: ...Appendix A Specifications Lithium Battery Disposal Warnings A 12 Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 ...

Страница 99: ...tions that list pinouts for the connectors used with the CSS 11050 CSS 11150 and CSS 11800 RJ 45 Fast Ethernet Connector Pinouts RJ 45 RS 232 Serial Connector Pinouts RJ 45 to RJ 45 CSS Cisco Console Adapter Cable Custom Cable Pinouts for Attaching the CSS Console Port to a Communication Server RJ 45 Timing BITS Connector Pinouts RJ 45 Management Connector Pinouts ...

Страница 100: ...thernet connectors on the CSS 11050 and CSS 11150 Fast Ethernet Module When using the Fast Ethernet connectors to connect the CSS to a Server or a workstation use a straight through cable Switch or a repeater use a crossover cable Table B 1 RJ 45 Fast Ethernet Connector Pinouts Signal Name RJ 45 Fast Ethernet Pin Numbers Crossover Cable Pinouts RX 1 3 RX 2 6 TX 3 1 Unconnected 4 4 Unconnected 5 5 ...

Страница 101: ...s provide both console and diagnostic functionality on each of its RJ 45 RS 232 Serial connectors Table B 2 lists the RJ 45 RS 232 Serial connector pinouts for the Console port Table B 3 lists the pinouts for the RJ 45 to DB 9 or RJ 45 to DB 25 console cables supplied in the CSS Console cable kit Table B 2 RJ 45 RS 232 Serial Connector Pinouts for the Console Port Signal Name Pin Number DTR 1 TXD ...

Страница 102: ... Diag1 and Diag2 ports on the SFM2 These ports provide both console and diagnostic functionality on each of its RJ 45 RS 232 Serial connectors Table B 4 RJ 45 RS 232 Serial Connector Pinouts for the Diag Port Signal Name Pin Number Not Used 1 TXD 2 RXD 3 Not Used 4 Not Used 5 Not Used 6 GND 7 Not Used 8 Table B 5 RJ 45 RS 232 Serial Connector Pinouts for the SFM2 Diag1 and Diag2 Port Signal Name P...

Страница 103: ...apter cable into the CSS console port you can connect a standard Cisco console cable to the adapter cable Note When you use the adapter cable to connect to a terminal server you must plug the adapter RJ 45 male connector directly into the CSS console port Then connect the adapter RJ 45 female connector to the terminal server interface cable Do not directly connect the adapter cable to the terminal...

Страница 104: ...25 connectors To connect a Cisco communication server to the CSS Console port review the communication server connections listed below and use the recommended cables A multi pin D type connector attached to an octal serial cable also known as an octopus cable or breakout cable provides a rollover DTE connection For this connection make an adapter cable using the connector pinouts defined in Table ...

Страница 105: ...5 to DB 9 or RJ 45 to DB 25 console cable to connect the communication server to the CSS both cables are included in the CSS Console cable kit Table B 7 CSS RJ 45 RS 232 Console Port Adapter Cable Pinouts Cable Not Reversible Communication Server DTE Signal Name Communication Server DTE Pin Number CSS Console Port Pin Number CSS Console Port Signal Name TXD 3 2 RXD GND 5 7 GND RXD 6 3 TXD Table B ...

Страница 106: ...ply Clock connector pinouts on the SCM RJ 45 Management Connector Pinouts Table B 10 lists RJ 45 Ethernet management connector pinouts on the CSS 11050 and CSS 11150 rear panel CSS 11800 front panel Table B 9 RJ 45 Timing BITS Connector Pinouts Signal Name Pin Number Bitsck 1 Bitsck 2 Unconnected 3 4 5 6 7 8 Table B 10 RJ 45 Management Connector Pinouts Signal Name Pin Number TX 1 TX 2 RX 3 Unconn...

Страница 107: ...ou need to file with your telephone company concerning connecting customer premise equipment CPE to 1 544 Mbps services This appendix includes the following major sections Regulatory Standards Compliance Canadian IC CS 03 Requirements FCC and Telephone Company Procedures and Requirements Korean Class A EMC Warning Korean Certification Information Declaration of Conformity with Regard to the Direct...

Страница 108: ...andards Compliance The following regulatory agencies have approved the CSS and have found it to be fully compliant with their environmental safety and emissions standards Table C 1 Regulatory Standards Compliance Regulatory Standards Compliance Regulatory Agency Safety UL 1950 C UL EN60950 GS Mark EMC FCC Part 15 EN55022 EN50082 1 VCCI Factory Approvals UL TUV BABT ...

Страница 109: ...e user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas...

Страница 110: ...t importante dans les régions rurales Avertissement L utilisateur ne doit pas tenter de faire ces raccordements lui méme il doit avoir recours a un service d inspection des installations électriques ou à un électricien selon le cas AVIS L indice d équivalence de la sonnerie IES assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent étre raccordés a une interface La...

Страница 111: ...e FCC Rules which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment Operation of the equipment in a residential area may cause interference Should this occur the user may be required to discontinue operation of the equipment or take other such measures as may be adequate to rectify the condition at the user s expense ...

Страница 112: ... certification information applies to the CSS 11000 series models The certification label on the CSS model provides the applicable certification number Trade Name or Applicant Cisco Systems Inc Manufacturing Date To determine the date see the explanation later in this section Manufacturer Nationality Cisco Systems Inc USA Warning This is a Class A Device and is registered for EMC requirements for ...

Страница 113: ... bar code The line of text consists of 11 characters similar to the following representation LLLYYWWSSSS This fields provide The location of the supplier LLL The year YY of manufacture The work week WW The sequential serial ID SSSS The year is in a coded format To determine the year of the Manufacturing Date see Table C 2 Table C 2 CSS Manufacturing Date Code and Associated Year Code YY Associated...

Страница 114: ...essential requirements and other provisions of Directives 73 23 EEC and 89 336 EEC as amended by Directive 93 68 EEC Español Este equipo cumple con los requisitos esenciales y otras disposiciones de las Directrices 73 23 EEC y 89 336 EEC de acuerdo a las modificaciones de la Directriz 93 68 EEC Français Cet appareil remplit les principales conditions requises et autres dispositions des Directives ...

Страница 115: ...s essenciais e outras provisões das Directivas 73 23 EEC e 89 336 EEC conforme amendados pela Directiva 93 68 EEC Cisco 11000 series CSS Suomalainen Tämä laite on direktiivien 73 23 ETY ja 89 336 ETY kuten muutettu direktiivissä 93 68 ETY keskeisten vaatimusten ja määräysten mukainen Svenska Denna utrustning uppfyller de väsentliga kraven och andra villkor i direktiven 73 23 EEC och 89 336 EEC enl...

Страница 116: ...Appendix C Regulatory Information Class A Warning for Taiwan and Other Traditional Chinese Markets C 10 Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 ...

Страница 117: ... 1 17 communication server attaching to Console port B 6 connectors 2 16 CSS 11050 front panel 2 3 2 4 CSS 11050 rear panel 2 3 CSS 11150 front panel 2 6 CSS 11150 rear panel 2 3 CSS 11800 CSS front panel connectors and LEDs 2 18 CSS 11800 front panel connectors and LEDs 2 13 2 21 2 24 pinouts B 1 console port baud rate 2 4 2 6 communication server attaching to B 6 configuring 2 15 custom cabling ...

Страница 118: ...s 1 15 unpacking 1 4 D damage to product 1 5 DB 37 V 35 WAN connector pinouts B 8 DC electrical specifications A 2 DC power cord connecting CSS 11150 2 27 connecting CSS 11800 2 30 DC power supply connector location for CSS 11150 2 28 connector location for CSS 11800 2 31 proper wiring sequence for CSS 11150 2 29 proper wiring sequence for CSS 11800 2 32 safety warnings A 9 disk failure 2 38 docum...

Страница 119: ...general specifications A 6 LED definitions 2 26 LEDs 2 24 power requirements A 6 specifications A 6 K Korean certification information C 6 L LEDs CSS 11050 front panel 2 3 2 4 CSS 11050 rear panel 2 3 CSS 11150 front panel 2 6 2 8 CSS 11150 rear panel 2 3 Fast Ethernet Module 2 18 Gigabit Ethernet Module 2 20 Internal Disk Module 2 24 2 26 Switch Control Module 2 14 license key locating 1 3 load b...

Страница 120: ...5 fast Ethernet connector B 2 RJ 45 management connector B 8 RJ 45 RS 232 serial connector B 3 RJ 45 timing BITS connector B 8 RJ 45 to RJ 45 Cisco console adapter cable B 5 power cords connecting 2 26 country requirements A 3 power supply load balancing 2 37 troubleshooting 2 36 protocols supported A 7 to A 9 R rack mounting CSS 11050 1 7 CSS 11150 1 7 radio frequency interference C 5 Regulatory ...

Страница 121: ...LED definitions 2 14 LEDs and connectors 2 13 Switch Fabric Module SFM and SFM2 LED definitions 2 24 LEDs 2 21 T telephone company procedures and requirements C 4 equipment problem resolution C 5 FCC and Telephone Company procedures and requirements C 4 terminal setting for console 2 32 tools and equipment required 1 2 transport protocol A 7 troubleshooting console port 2 35 modules 2 37 power sup...

Страница 122: ...Index IN 6 Cisco 11000 Series Content Services Switch Hardware Installation Guide 78 15146 02 ...

Отзывы: