Power Requirements
• PWR-C1-1100WAC: 3754 BTUs per hour, 1100 W
• PWR-C1-1100WAC-P: 3754 BTUs per hour, 1100 W
• PWR-C1-715WAC: 2440 BTUs per hour, 715 W
• PWR-C1-715WAC-P: 2440 BTUs per hour, 715 W
• PWR-C1-350WAC: 1194 BTUs per hour, 350 W
• PWR-C1-350WAC-P: 1194 BTUs per hour, 350 W
Total output BTU
6
The total input and total output BTU ratings refer to input power to the power supply and output power
to the switch. The BTU ratings are based on 100 VAC for the 350-W and 715-W power supplies and
115 VAC for the 1100-W power supply.
Table 41: Power Specifications for DC Power
Power Requirements
PWR-C1-715WDC: 715 W
Maximum output power
PWR-C1-715WDC: 24–12 A
Input current
PWR-C1-715WDC: -56 V at 12.8 A
Output ratings
PWR-C1-715WDC: –36 VDC (minimum), –48 VDC (nominal), –72
VDC (maximum)
Input voltage range domestic
PWR-C1-715WDC: –36 VDC (minimum), –48 VDC (nominal), –72
VDC (maximum)
Voltage range international
PWR-C1-715WDC: 2777 BTUs per hour, 715 W
Total input BTU
PWR-C1-715WDC: 2440 BTUs per hour
Total output BTU
PWR-C1-715WDC: 12 AWG or 8 AWG
Wire gauge for ground connection
PWR-C1-715WDC: 20 A
Branch circuit protection
7
The total input and total output BTU ratings refer to input power to the power supply and output power
to the switch. The BTU ratings are based on -40 VDC.
Table 42: Fan Module Environmental and Physical Specifications
Environmental Ranges
23 to 176°F (–5 to 80°C)
Operating temperature
–40 to 185°F (–40 to 85°C) up to 15,000 ft (4500 m)
Storage temperature
5 to 95% (noncondensing)
Relative humidity
Up to 13,000 ft (4000 m)
Altitude
Cisco Catalyst 9300 Series Switches Hardware Installation Guide
110
Technical Specifications
Technical Specifications