A P P E N D I X
A
Technical Specifications
•
Environmental and Physical Specifications, on page 105
•
Specifications for the Power Supplies, Switches, and Fan, on page 109
•
AC Power Cord Specifications, on page 111
Environmental and Physical Specifications
This table describes the environmental specifications.
Table 35: Environmental Specifications for the Switch
Environmental Ranges
23 to 113°F (–5 to 45°C)
Operating temperature
–40 to 158°F (–40 to 70°C)
Storage temperature
5 to 90% (noncondensing)
Relative humidity
Up to 10,000 ft (3000 m)
Operating altitude
Up to 15,000 ft (4500 m)
Storage altitude
5
Minimum ambient temperature for cold start is 32°F (0°C)
This table describes the environmental specifications.
Table 36: Environmental Specifications for the Power Supplies
Environmental Ranges
23°F to 113°F (–5°C to 45°C) up to 5000 feet (1500m)
23°F to 104°F (–5°C to 40ºC) up to 10,000 feet (3000m)
Operating temperature
–40 to 158°F (–40 to 70°C)
Storage temperature
10 to 90% (noncondensing)
Relative humidity
10,000 ft (3,000 m) up to 40°C
Altitude