background image

   

1-9

Catalyst 4000 Series Switch Installation Guide

78-6120-10

Chapter 1      Product Overview

    Switch Features

Embedded 
management

Full SNMP implementation, including entity-MIB, all relevant standard 
MIBs, and all relevant Cisco MIBs

The first four RMON groups (Ethernet statistics, Alarms, Events, and 
History) on a per-port basis without an optional RMON processing 
module

SPAN, allowing you to redirect traffic from any port or VLAN to a SPAN 
destination port

Performance management information 

Power supplies

Three 400 W, 12 V output, hot-swappable, load-sharing power supplies 
with AC power factor correctionOptional 400 W, 12 V output DC power 
supplies

Optional 650 W, 12 V output DC power supplies

Supervisor engine

Supports the Supervisor Engine II (WS-X4013), Supervisor Engine III 
(WS-X4014), and Supervisor Engine IV (WS-X4515)

Data path and control for all network interfaces with Ethernet 
management and console ports

Interface monitoring, environmental status, and SNMP and 
console/Telnet interface

Note

Packets are not forwarded while the supervisor engine is removed; a 
system reboot occurs when a supervisor engine is reinserted. 

32-port full-duplex Gigabit Ethernet switching engine

Two Gigabit Ethernet (1000BASE-X) interfaces for backbone 
interconnection of high-performance switches and routers

Table 1-2

Features of the Catalyst 4006 Switch (continued)

Feature

Description

Содержание Catalyst 4124

Страница 1: ...ns these sections Switch Features page 1 1 Switch Components page 1 12 Switch Features The following sections describe the features of the Catalyst 4000 series switches Catalyst 4003 Switch Features page 1 1 Catalyst 4006 Switch Features page 1 7 Catalyst 4003 Switch Features The Catalyst 4003 switch see Figure 1 1 is a three slot switch designed for high performance high density wiring closet app...

Страница 2: ...e I has a 10BASE T Ethernet management port RJ 45 connector and a console port DCE DB 25 connector The Catalyst 4003 chassis has three slots for online swappable modules Slot 1 is reserved for the supervisor engine which provides switching local and remote management and switch status monitoring Slots 2 and 3 are available for switching modules Table 1 1 describes the features of the Catalyst 4003...

Страница 3: ...es Two power supply bays that support one required and one optional redundant AC input power supply One hot swappable fan assembly Standard management and support Layer 2 forwarding with an aggregate forwarding rate of greater than 17 8 million pps 16 000 MAC addresses per system Up to 1 024 VLANs with IEEE 802 1Q VLAN tagging on all ports and support for VTP1 Port aggregation using PAgP2 for 100 ...

Страница 4: ...e load sharing redundant power supplies with AC power factor correction Optional 400 W 12 V output DC power supplies Optional 650 W 12 V output DC power supplies PoE is not supported on the Catalyst 4003 Supervisor engine Supports the Supervisor Engine I WS X4012 Data path and control for all network interfaces with Ethernet management and console ports Interface monitoring environmental status an...

Страница 5: ...4148 RJ21 48 port Cisco prestandard Power over Ethernet PoE 10 100BASE TX switching module WS X4148 RJ45V 7 24 port IEEE 802 3af compliant PoE 10 100BASE TX switching module WS X4224 RJ45V 7 48 port IEEE 802 3af compliant PoE 10 100BASE TX RJ 21 switching module WS X4248 RJ21V 7 48 port IEEE 802 3af compliant PoE 10 100BASE TX switching module WS X4248 RJ45V 7 32 port 10 100 Mbps Fast Ethernet plu...

Страница 6: ...10 100 1000BASE TX Gigabit Ethernet switching module WS X4448 GB RJ45 24 port IEEE 802 3af compliant PoE 10 100 1000 BASE T RJ 45 switching module WS X4524 GB RJ45V 7 48 port 10 100 1000BASE T Gigabit Ethernet switching module WS X4548 GB RJ45 48 port Gigabit Ethernet switching module WS X4448 GB SFP 48 port IEEE 802 3af compliant PoE 10 100 1000 BASE T RJ 45 switching module WS X4548 GB RJ45V 7 A...

Страница 7: ...shortwave SX LX LH and ZX GBICs For a description of GBICs refer to the Catalyst 4500 Series Module Installation Guide The Catalyst 4006 chassis has six slots for online swappable modules Slot 1 is reserved for the supervisor engine which provides switching local and remote management and switch status monitoring The Catalyst 4006 switch supports the Supervisor Engine II III or IV Slots 2 through ...

Страница 8: ...or switching modules Three power supply bays that support two required and one optional redundant AC input power supply One hot swappable fan assembly Standard management and support Supports Layer 2 forwarding with an aggregate forwarding rate of 18 million pps Supports 16 000 MAC addresses per system Supports up to 1 024 VLANs with IEEE 802 1Q VLAN tagging on all ports and support for VTP1 Suppo...

Страница 9: ...factor correctionOptional 400 W 12 V output DC power supplies Optional 650 W 12 V output DC power supplies Supervisor engine Supports the Supervisor Engine II WS X4013 Supervisor Engine III WS X4014 and Supervisor Engine IV WS X4515 Data path and control for all network interfaces with Ethernet management and console ports Interface monitoring environmental status and SNMP and console Telnet inter...

Страница 10: ...switching module WS X4148 RJ21 48 port Cisco pre standard Power over Ethernet PoE 10 100BASE TX switching module WS X4148 RJ45V 24 port IEEE 802 3af compliant PoE 10 100BASE TX switching module WS X4224 RJ45V 48 port IEEE 802 3af compliant PoE 10 100BASE TX RJ 21 switching module WS X4248 RJ21V 48 port IEEE 802 3af compliant PoE 10 100BASE TX switching module WS X4248 RJ45V 32 port 10 100 Mbps Fas...

Страница 11: ...odule WS X4448 GB LX 48 port 10 100 1000BASE TX Gigabit Ethernet switching module WS X4448 GB RJ45 24 port IEEE 802 3af compliant PoE 10 100 1000 BASE T RJ 45 switching module WS X4524 GB RJ45V 48 port 10 100 1000BASE T Gigabit Ethernet switching module WS X4548 GB RJ45 48 port Gigabit Ethernet switching module WS X4448 GB SFP 48 port IEEE 802 3af compliant PoE 10 100 1000 BASE T RJ 45 switching m...

Страница 12: ...AC input power supplies The following components are available as options for the Catalyst 4006 switch One additional AC input power supply for redundancy Up to five switching modules One or more DC input power supplies for redundancy Fan Assembly Note For complete environmental specifications including airflow requirements see Appendix A Specifications The system fan assembly provides cooling air...

Страница 13: ... 1 Product Overview Switch Components Caution You must install module filler plates on unused switching module slots to ensure proper airflow Figure 1 3 Catalyst 4003 Airflow 16668 THIS ASSEMBLY CONTAINS ELECTROSTATIC SENSITIVE DEVICES CAUTION 1 13 1 13 0 100 Fan assembly ...

Страница 14: ...shold the environmental monitor displays warning messages Threshold and status level descriptions are provided in the Power Supplies section To replace a fan assembly see Chapter 4 Removing and Replacing FRUs Note For complete power specifications see Appendix A Specifications THIS ASSEM BLY CONTA INS ELECT ROSTA TIC SENSI TIVE DEVIC ES CAUTI ON Power Supply 1 Power Supply 2 Power Supply 3 1 13 1 ...

Страница 15: ...y has a power cord that connects each power supply to the site power source The DC input power supplies are equipped with a compression style input terminal block that is directly connected to the site power wiring The power supply does not have a power switch Power is provided when the power cord and wiring are installed and plugged into an electrical outlet and the unit is fully seated in the sy...

Страница 16: ...redundant power supplies Each power supply has an individual power cord and status LEDs The Catalyst 4003 switch has one standard power supply and an optional redundant power supply The 38133 DC power connection Captive screws 48 60V 11A FASTNERS MUST BE FULLY ENGAGED PRIOR TO OPERATING POWER SUPPLY 68609 DC power connection Captive screws 48 60V 18A GOOD FAIL FASTNERS MUST BE FULLY ENGAGED PRIOR ...

Страница 17: ...Supply section on page 4 2 Power Supply LEDs The AC power supply has two front panel LEDs The LED labeled GOOD is green when the power supply is connected and operating normally The LED labeled FAIL is red when there is a problem with the power supply Power Supply Fan Each power supply has a built in fan Air enters the front of the power supply power input end and exits through the back An air dam...

Страница 18: ...ower supply shuts down to prevent damage When the power supply returns to a safe operating temperature it restarts If the power supply output voltage is abnormal the LED labeled OUTPUT FAIL will light An instance of substantial input overvoltage can shut down the power supply The supervisor engine monitors the status of each power supply and provides a status report through the switch software For...

Отзывы: