background image

Figure 82: Port Settings

What to do next

• Click

Day 0 Config Summary

to verify your setup.

• Click

Finish

.

Catalyst 3850 Switch Hardware Installation Guide

OL-26779-05

106

Configuring the Switch

Configuring Port Settings

Содержание Catalyst 3850

Страница 1: ...uide First Published 2013 01 21 Last Modified 2015 09 22 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Text Part Number OL 26779 05 ...

Страница 2: ...h Models 1 Front Panel 6 10 100 1000 Ports 8 PoE PoE and Cisco UPoE Ports 8 SFP and QSFP Module Slots 9 Management Ports 9 USB Type A Port 10 Network Modules 11 SFP and SFP Modules 13 LEDs 13 SYST LED 16 XPS LED 16 Port LEDs and Modes 17 USB Console LED 19 S PWR LED 19 ACTV LED 20 STACK LED 20 PoE LED 21 UID Beacon LED 21 Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 ii Contents ...

Страница 3: ...the Switch 36 Planning a Switch Data Stack 36 Switch Stacking and Power Stacking Guidelines 37 Data Stack Cabling Configurations 38 Data Stack Bandwidth and Partitioning Examples 38 Power On Sequence for Switch Stacks 39 Planning a StackPower Stack 40 StackPower Stacking Guidelines 40 StackPower Cabling Configurations 41 StackPower Partitioning Examples 42 Installing the Switch 43 Rack Mounting 43...

Страница 4: ...witch 58 Safety Warnings 58 Equipment That You Need 59 Installing Network Modules 59 Network Module Port Configurations 61 C3850 NM 4 1G Module 61 C3850 NM 4 10G Module 61 C3850 NM 2 10G Module 62 C3850 NM 8 10G Module 62 C3850 NM 2 40G Module 63 Removing a Network Module 64 Installing SFP and SFP Modules 65 Removing SFP and SFP Modules 66 Finding the Network Module Serial Number 67 Power Supply I...

Страница 5: ... Profile 92 Configuring Switch Wide Settings 101 Configuring VLAN Settings 101 Configure STP Settings 102 Configuring DHCP NTP DNS and SNMP Settings 103 Configuring Port Settings 105 Configuring the Switch Using the CLI 107 Accessing the CLI Through the Console Port 107 Connecting the RJ 45 Console Port 108 Connecting the USB Console Port 108 Installing the Cisco Microsoft Windows USB Device Drive...

Страница 6: ...formance 118 Speed Duplex and Autonegotiation 118 Autonegotiation and Network Interface Cards 118 Cabling Distance 118 Clearing the Switch IP Address and Configuration 118 Replacing a Failed Data Stack Member 119 Technical Specifications 121 A P P E N D I X A Environmental and Physical Specifications 121 Specifications for the Power Supplies Switches and Fan 123 Connector and Cable Specifications ...

Страница 7: ...SFP Module Cables 129 Cisco QSFP to SFP or SFP Adapter 130 Cable Pinouts 130 Console Port Adapter Pinouts 131 Catalyst 3850 Switch Hardware Installation Guide vii OL 26779 05 Contents ...

Страница 8: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 viii Contents ...

Страница 9: ... are encouraged to try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product...

Страница 10: ......

Страница 11: ...t titles new or emphasized terms and arguments for which you supply values are in italic font Italic font Terminal sessions and information the system displays appear in courier font Courier font Bold Courier font indicates text that the user must enter Bold Courier font Elements in square brackets are optional x An ellipsis three consecutive nonbolded periods without spaces after a syntax element...

Страница 12: ... suggestions or references to material not covered in the manual Note Means the following information will help you solve a problem Tip Means reader be careful In this situation you might do something that could result in equipment damage or loss of data Caution Means the described action saves time You can save time by performing the action described in the paragraph Timesaver IMPORTANT SAFETY IN...

Страница 13: ... US products hw modules ps5455 tsd_products_support_series_home html Cisco Validated Designs documents located at http www cisco com go designzone Obtaining Documentation and Submitting a Service Request For information on obtaining documentation submitting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and ...

Страница 14: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 xiv Preface Obtaining Documentation and Submitting a Service Request ...

Страница 15: ... a switch stack This chapter contains these topics Switch Models on page 1 Front Panel on page 6 Rear Panel on page 22 Management Options on page 31 Switch Models Table 1 Catalyst 3850 Switch Models and Descriptions Description Supported Software Image Switch Model Stackable 24 10 100 1000 Ethernet ports 1 network module slot 350 W power supply LAN Base WS C3850 24T L Stackable 48 10 100 1000 Ethe...

Страница 16: ...k module slot 350 W power supply IP Base WS C3850 24T S Stackable 48 10 100 1000 Ethernet ports 1 network module slot 350 W power supply IP Base WS C3850 48T S Stackable 24 10 100 1000 PoE ports 1 network module slot 715 W power supply IP Base WS C3850 24P S Stackable 48 10 100 1000 PoE ports 1 network module slot 715 W power supply IP Base WS C3850 48P S Stackable 48 10 100 1000 PoE ports 1 netwo...

Страница 17: ...3850 NM 4 10G network module is plugged into the WS C3850 12XS S switch IP Base WS C3850 16XS S Catalyst 3850 24 port SFP transceiver 1 network module slot support for up to 10 G SFP 715 W power supply IP Base WS C3850 24XS S Catalyst 3850 32 port SFP transceiver 1 network module slot support for up to 10 G SFP 715 W power supply 32 ports are available when the C3850 NM 8 10G network module is plu...

Страница 18: ...ork module slot 1100 W power supply IP Base WS C3850 24XU S Stackable 24 100M 1G 2 5G 5G 10G UPoE ports 1 network module slot 1100 W power supply IP Base WS C3850 24XUW S Stackable 24 10 100 1000 Ethernet ports 1 network module slot 350 W power supply IP Services WS C3850 24T E Stackable 48 10 100 1000 Ethernet ports 1 network module slot 350 W power supply IP Services WS C3850 48T E Stackable 24 ...

Страница 19: ...P 350 W power supply IP Services WS C3850 12XS E Catalyst 3850 16 port SFP transceiver 1 network module slot support for up to 10 G SFP 350 W power supply 16 ports are available when the C3850 NM 4 10G network module is plugged into the WS C3850 12XS E switch IP Services WS C3850 16XS E Catalyst 3850 24 port SFP transceiver 1 network module slot support for up to 10 G SFP 715 W power supply IP Ser...

Страница 20: ...ule slot 1100 W power supply IP Services WS C3850 12X48U E Stackable 24 100M 1G 2 5G 5G 10G UPoE ports 1 network module slot 1100 W power supply IP Services WS C3850 24XU E 1 For supported network modules see Network Modules on page 11 2 PoE Power over Ethernet plus provides up to 30 W per port 3 UPOE Universal Power Over Ethernet provides up to 60 W Cisco UPOE per port 4 The WS C3850 48XS switche...

Страница 21: ...anel USB mini Type B console port 4 Mode button 1 10 100 1000 PoE ports 5 Status LEDs 2 Network module 6 USB Type A storage port 3 Figure 2 WS C3850 24S Switch Front Panel The WS C3850 12S switches have similar front panels Note USB Type A storage port 5 UID button 1 SFP module slots downlink 6 Mode button 2 Network module 7 Status LEDs 3 Catalyst 3850 Switch Hardware Installation Guide 7 OL 26779...

Страница 22: ...UPoE ports use the same connectors as described in 10 100 1000 Port Connections on page 49 They provide PoE ports Support for IEEE 802 3af compliant powered devices up to 15 4 W PoE per port and support for IEEE 802 3at compliant powered devices up to 30 W PoE per port The maximum total PoE power in a 1RU switch is 1800 W Support for Cisco enhanced PoE Support for prestandard Cisco powered devices...

Страница 23: ...XS F E switch models support standard SFP modules The 40G downlink ports on the Catalyst WS C3850 48XS S WS C3850 48XS F S WS C3850 48XS E and WS C3850 48XS F E switch models support standard QSFP modules For supported SFP modules refer to the Cisco Transceiver Modules Compatibility Information at http www cisco com en US products hw modules ps5455 products_device_support_tables_list html For info...

Страница 24: ...e software guide USB Type A Port The USB Type A port provides access to external USB flash devices also known as thumb drives or USB keys and to specific Cisco USB Bluetooth devices The port supports Cisco USB flash drives with capacities from 128 MB to 8 GB USB devices with port densities of 128 MB 256 MB 1 GB 4 GB and 8 GB are supported When combined with stacking you can upgrade other switches ...

Страница 25: ...k Modules Description Network Module 5 This module has four 1 G SFP module slots Any combination of standard SFP modules are supported SFP modules are not supported If you insert an SFP module in the 1 G network module the SFP module does not operate and the switch logs an error message This is supported on the following switch models Note WS C3850 24T P U WS C3850 48T F P U WS C3850 12X48U WS C38...

Страница 26: ...8U WS C3850 24XU WS C3850 12XS WS C3850 24XS C3850 NM 4 10G This module has eight 10 G slots with an SFP port in each slot Each port supports a 1 G or 10 G connection This is supported on the following switch models Note WS C3850 12X48U WS C3850 24XU WS C3850 24XS C3850 NM 8 10G This module has two 40 G slots with a QSFP connector in each slot This is supported on the following switch models Note ...

Страница 27: ...Cisco SFP and SFP modules on the switch For the latest information about supported SFP and SFP modules refer to the Cisco Transceiver Modules Compatibility Information at http www cisco com en US products hw modules ps5455 products_device_support_tables_list html For information about SFP modules see the documentation at Installing SFP and SFP Modules on page 65 The Catalyst 3850 switch supports t...

Страница 28: ... a port mode USB mini Type B console port LED 6 STAT status 1 SYST system 7 DUPLX duplex 2 ACTV active 8 SPEED 3 XPS 6 9 STACK 4 S PWR StackPower 10 PoE 5 6 XPS expandable power system 7 Only on switch models that support PoE Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 14 Product Overview LEDs ...

Страница 29: ...e B console port LED 6 UID blue beacon 1 SYST system 7 STAT status 2 ACTV active 8 DUPLX duplex 3 XPS 8 9 SPEED 4 S PWR StackPower 10 STACK 5 8 XPS expandable power system Figure 8 Switch Front Panel LEDs for the WS C3850 48XS Switches Catalyst 3850 Switch Hardware Installation Guide 15 OL 26779 05 Product Overview LEDs ...

Страница 30: ...StackPower mode Off XPS is connected and ready to provide back up power Green XPS is connected but is unavailable because it is providing power to another device redundancy has been allocated to a neighboring device Blinking green The XPS is in standby mode or in a fault condition See the XPS 2200 documentation for information about the standby mode and fault conditions Amber The power supply in a...

Страница 31: ...rating speed 10 100 or 1000 Mb s Port speed SPEED The port duplex mode full duplex or half duplex Port duplex mode DUPLX The active switch status Active ACTV Stack member status The StackWise port status See STACK LED on page 20 Stack member status StackWise port status STACK The PoE port status The PoE port status PoE9 9 Only switches with PoE ports Table 6 Meaning of Switch LED Colors in Differe...

Страница 32: ...Port is operating in full duplex Green The switch is not the active switch For a standalone switch this LED is off Note Off ACTV data active switch The switch is the active switch Green Error during active switch election Amber Switch is a standby member of a data stack and assumes active responsibilities if the current active switch fails Blinking green No stack member corresponding to that membe...

Страница 33: ...onnect Cisco prestandard IP Phones and wireless access points or IEEE 802 3af compliant devices to PoE ports You must remove from the network any cable or device that causes a PoE fault Caution Blinking amber PoE for the port has been disabled PoE is enabled by default Note Amber 10 Only switches with PoE or PoE ports USB Console LED The USB console LED shows whether there is an active USB connect...

Страница 34: ...ode Slow blinking green An error occurred when the switch was selecting the active switch or another type of stack error occurred Amber STACK LED The STACK LED shows the sequence of member switches in a stack Up to nine switches can be members of a stack The first nine port LEDs show the member number of a switch in a stack Figure 9 STACK LED This figure shows the LEDs on for each switch When you ...

Страница 35: ...t least one of the 10 100 1000 ports has a PoE mode fault Blinking amber UID Beacon LED The UID and the Beacon LED can be turned on by the administrator to indicate that the switch needs attention It helps the administrator identify the switch The beacon can be turned on by either pressing the UID button on the switch front panel or by using the CLI There is a blue beacon on the front and rear pan...

Страница 36: ...n the switch software Link faults occur when noncompliant cabling is connected to an SFP SFP port Use only standard compliant cabling to connect to Cisco SFP SFP ports You must remove from the network any cable or device that causes a link fault Caution Blinking amber Link for the SFP SFP has been disabled Amber Rear Panel The switch rear panel includes StackWise connectors StackPower or XPS 2200 ...

Страница 37: ...000 management port 3 PS OK output status LED 9 RESET button 4 Power supply modules AC power supply modules shown 10 Fan module 5 Figure 12 WS C3850 12S and WS C3850 24S Switches Switch Rear Panel StackWise port connector 7 Ground connector 1 StackPower connector 8 CONSOLE RJ 45 console port 2 Catalyst 3850 Switch Hardware Installation Guide 23 OL 26779 05 Product Overview Rear Panel ...

Страница 38: ...tatus LED 10 RESET button 4 Power supply modules AC power supply modules shown 11 BEACON LED 5 Fan module 6 Figure 13 WS C3850 48XS Switches Switch Rear Panel Fan module 5 Ground connector 1 Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 24 Product Overview Rear Panel ...

Страница 39: ...0 5 meter StackWise cable that you can use to connect the StackWise ports For more information on StackWise cables see Connecting to the StackWise Ports on page 47 The following switch models do not support StackWise 480 WS C3850 48XS S WS C3850 48XS E WS C3850 48XS F S WS C3850 48XS F E Note Use only approved cables and connect only to similar Cisco equipment Equipment might be damaged if connect...

Страница 40: ...els on page 1 shows the default power supply modules that ship with each switch model All power supply modules except the blank modules have internal fans All switches ship with a blank power supply module in the second power supply slot Do not operate the switch with one power supply module slot empty For proper chassis cooling both power supply module slots must be populated with either a power ...

Страница 41: ...W 1 24 port Cisco UPOE switch 660 W 2 185 W 1 48 port Cisco UPOE switch 625 W 2 Table 15 Switch Power Supply Requirements for PoE PoE and Cisco UPoE 48 Port Switch 11 24 Port Switch PoE Option These are the combinations of power supplies 1 1100 W 1 715 W 1 715 W 1 715 W PoE up to 15 4 per port These are the combinations of power supplies 1 1100 W 1 715 W 2 1100 W These are the combinations of powe...

Страница 42: ...bled or input is outside operating range DC LED is off Off No AC input power No DC input power Off Power output to switch active Green AC input power present DC input power present Green Output has failed Red For information about replacing a power supply module wiring a DC power supply module and module specifications see the Power Supply Installation and Technical Specifications chapters Fan Mod...

Страница 43: ...how the airflow patterns for the 24 and 48 port switches The blue arrow shows cool airflow and the red arrow shows warm airflow Figure 15 Airflow Patterns for the Catalyst 3850 24S E and 3850 12S E Switches Figure 16 Airflow Patterns for the Catalyst 3850 48XS Switches using Power Supplies and Fans with Blue Handles Catalyst 3850 Switch Hardware Installation Guide 29 OL 26779 05 Product Overview F...

Страница 44: ...wer cables and StackPower guidelines see Planning a StackPower Stack on page 40 Cisco Catalyst WS C3850 48XS switch models do not have the StackPower connector Note Ethernet Management Port You can connect the switch to a host such as a Windows workstation or a terminal server through the 10 100 1000 Ethernet management port or one of the console ports The 10 100 1000 Ethernet management port is a...

Страница 45: ... cost and can be downloaded from this URL http www cisco com pcgi bin tablebuild pl NetworkAssistant Cisco IOS CLI You can configure and monitor the switch and switch cluster members from the CLI You can access the CLI by connecting your management station directly to the switch console port or by using Telnet from a remote management station See the switch command reference on Cisco com for more ...

Страница 46: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 32 Product Overview Management Options ...

Страница 47: ... on page 49 Installing and Removing SFP SFP and QSFP Modules on page 49 Connecting Devices to the Ethernet Ports on page 49 Where to Go Next on page 51 Preparing for Installation Safety Warnings This section includes the basic installation caution and warning statements Read this section before you start the installation procedure Translations of the warning statements appear in the Regulatory Com...

Страница 48: ...cess area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Statement 1019 Warning Use copper conductors only Statement 1025 Warning This unit might have more than one power supply connection All connections must be remov...

Страница 49: ...ion Cabling is away from sources of electrical noise such as radios power lines and fluorescent lighting fixtures Make sure that the cabling is safely away from other devices that might damage the cables For switches with the optional 1100 W power supply module PWR C1 1100WAC first rack mount the switch before installing the power supply module Make sure power supply modules and fan modules are se...

Страница 50: ...s A Number 2 Phillips screwdriver to rack mount the switch Verifying Switch Operation Before you install the switch in a rack or on a table or shelf you should power on the switch and verify that the switch passes POST See the Running Express Setup section in the getting started guide for the steps required to connect a PC to the switch and to run Express Setup Powering Off the Switch After a succ...

Страница 51: ...nfigurations For rack mounted switch stacks that are members of a StackPower stack as well as a data stack see Planning a StackPower Stack on page 40 You can create data stacks with up to nine switches in a stack Special considerations for the following switch models WS C3850 24XS E WS C3850 24XS S WS C3850 24XU E WS C3850 24XU L WS C3850 24XU S WS C3850 12X48U L WS C3850 12X48U S WS C3850 12X48U ...

Страница 52: ... side Use the 1 meter and the 3 meter StackWise cables to connect the switches This configuration provides redundant connections Figure 19 Data Stacking in a Side by Side Mounting Data Stack Bandwidth and Partitioning Examples This section provides examples of data stack bandwidth and possible data stack partitioning The figure shows a data stack of switches that provides full bandwidth and redund...

Страница 53: ... Switch Stacks Consider these guidelines before you power on the switches in a stack The sequence in which the switches are first powered on might affect the switch that becomes the stack master There are two ways to elect an active switch If you want a particular switch to become the active switch configure it with the highest priority Among switches with same priority the switch with the lowest ...

Страница 54: ... how the switches are connected You can remove two or more switches from the stack without splitting the stack Note For conditions that can cause a stack reelection or to manually elect the active switch see the stacking software configuration guide on Cisco com at this URL http www cisco com c en us support switches catalyst 3850 series switches products installation and configuration guides list...

Страница 55: ...examples of recommended configurations For rack mounted switch stacks that are members of a data stack and a StackPower stack see Switch Stacking and Power Stacking Guidelines on page 37 StackPower Cabling Configurations This section describes the recommended cabling configurations for a StackPower stack There are two types of StackPower cables The cable in the figure connects a switch to another ...

Страница 56: ...logy StackPower Partitioning Examples These figures show StackPower stacks of switches with failover conditions In this figure the StackPower cable 2 is faulty Therefore this stack does not provide redundancy Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 42 Switch Installation StackPower Partitioning Examples ...

Страница 57: ...dily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest compone...

Страница 58: ...4 inch brackets C3850 RACK KIT 5 Extension rails and brackets for four point mounting includes 19 inch brackets C3850 4PT KIT 2 ETSI brackets C3850 RACK KIT 3 Attaching the Rack Mount Brackets Procedure Use four Phillips flat head screws to attach the long side of the bracket to each side of the switch for the front or rear mounting positions Catalyst 3850 Switch Hardware Installation Guide OL 267...

Страница 59: ...ets for 19 inch Racks Front mounting position 3 Rear mounting position 1 Number 8 Phillips flat head screws 2 Catalyst 3850 Switch Hardware Installation Guide 45 OL 26779 05 Switch Installation Attaching the Rack Mount Brackets ...

Страница 60: ...ttach the brackets to the rack Step 2 Use the black Phillips machine screw to attach the cable guide to the left or right bracket Front mounting position 4 Phillips machine screw black 1 Number 12 or number 10 Phillips machine screws 5 Cable guide 2 Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 46 Switch Installation Mounting the Switch a Rack ...

Страница 61: ...the front panel ports Connecting to the StackWise Ports Before you begin Before connecting the StackWise cables review the Planning a Switch Data Stack on page 36 Always use a Cisco approved StackWise cable to connect the switches Procedure Step 1 Remove the dust covers from the StackWise cables and StackWise ports and store them for future use Step 2 Connect the cable to the StackWise port on the...

Страница 62: ...s When the connectors are not being used replace the dust covers Connecting to the StackPower Ports Before you begin Before connecting the StackPower cables review Planning a Switch Data Stack on page 36 Always use a Cisco approved StackWise cable to connect the switches To prevent misconfiguration the StackPower ports on the switch are keyed and have colored bands that match the keying and bands ...

Страница 63: ...n the Switch See these sections for information on network modules Installing Network Modules on page 59 Installing and Removing SFP SFP and QSFP Modules See these sections for information on SFP SFP and QSFP modules Installing SFP and SFP Modules on page 65 Removing SFP and SFP Modules on page 66 Cisco 40 Gigabit QSFP Transceiver Modules Installation Note Connecting Devices to the Ethernet Ports ...

Страница 64: ...les When Auto MDIX is Disabled Straight Through Cable Crossover Cable Device No Yes Switch to switch No Yes Switch to hub Yes No Switch to computer or server Yes No Switch to router Yes No Switch to IP phone 12 100BASE TX and 1000BASE T traffic requires twisted four pair Category 5 or higher 10BASE T traffic can use Category 3 cable or higher PoE and Cisco UPOE Port Connections The 10 100 1000 PoE...

Страница 65: ...nd the emergency calling service In the USA this emergency number is 911 You need to be aware of the emergency number in your country Statement 371 Warning Category 5e and Category 6 cables can store high levels of static electricity Always ground the cables to a suitable and safe earth ground before connecting them to the switch or other devices Caution Noncompliant cabling or powered devices can...

Страница 66: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 52 Switch Installation Where to Go Next ...

Страница 67: ...ule Overview Description Network Module 13 This module has four 1 G SFP module slots Any combination of standard SFP modules are supported SFP modules are not supported If you insert an SFP module in the 1 G network module the SFP module does not operate and the switch logs an error message This is supported on the following switch models Note WS C3850 24T P U WS C3850 48T F P U WS C3850 12X48U WS...

Страница 68: ...50 24XU WS C3850 12XS WS C3850 24XS C3850 NM 4 10G This module has eight 10 G slots with an SFP port in each slot Each port supports a 1 G or 10 G connection This is supported on the following switch models Note WS C3850 12X48U WS C3850 24XU WS C3850 24XS C3850 NM 8 10G This module has two 40 G slots with a QSFP connector in each slot This is supported on the following switch models Note WS C3850 ...

Страница 69: ...Ds 3 Captive screws 1 1 G Ethernet SFP slots 2 Figure 35 C3850 NM 2 10G Network Module 1 G Ethernet SFP slots 3 Captive screws 1 LEDs 4 1 G or 10 G Ethernet SFP slots 2 Catalyst 3850 Switch Hardware Installation Guide 55 OL 26779 05 Installing a Network Module Network Module Overview ...

Страница 70: ...rk Module LEDs 3 Captive screw This network module has only one screw You must fasten the screw completely to secure the module and loosen the screw first so that the module may be removed Note 1 10 G or 1 G SFP slots 2 Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 56 Installing a Network Module Network Module Overview ...

Страница 71: ... 1 40 G QSFP slots 2 Figure 39 Blank Network Module Captive screws 2 Blank module 1 Network Module LEDs Figure 40 Network Module LEDs G3 LED 3 G1 LED 1 Catalyst 3850 Switch Hardware Installation Guide 57 OL 26779 05 Installing a Network Module Network Module LEDs ...

Страница 72: ...nings Translations of the safety warnings appear in the Regulatory Compliance and Safety Information for the Catalyst 3850 Switches on Cisco com http www cisco com go cat3850_hw Read this section before you install a network module Proper ESD protection is required whenever you handle equipment Installation and maintenance personnel should be properly grounded by grounding straps to eliminate the ...

Страница 73: ...ock Installing Network Modules The switch can operate without a network module but a blank module with no ports or SFP slots is available and should be installed when uplink ports are not required Note The switch generates logs when you insert or remove a network module with SFP slots Note Use only supported network modules and SFP or SFP modules Each module has an internal serial EEPROM that is e...

Страница 74: ...entation of your module before installing it Incorrect installation can damage the module Caution Do not install the network module with connected cables or installed SFP modules Always remove any cables and modules before you install the network module Caution A module interface might become error disabled when a network module with connected fiber optic cables is installed or removed If an inter...

Страница 75: ...they still show up in the CLI Table 20 C3850 NM 4 1G Module Action Interface Configure this interface GigabitEthernet1 1 1 Configure this interface GigabitEthernet1 1 2 Configure this interface GigabitEthernet1 1 3 Configure this interface GigabitEthernet1 1 4 Disregard TenGigabitEthernet1 1 1 Disregard TenGigabitEthernet1 1 2 Disregard TenGigabitEthernet1 1 3 Disregard TenGigabitEthernet1 1 4 C38...

Страница 76: ...gh they still show up in the CLI Table 22 C3850 NM 2 10G Module Action Interface Configure this interface GigabitEthernet1 1 1 Configure this interface GigabitEthernet1 1 2 Disregard GigabitEthernet1 1 3 Disregard GigabitEthernet1 1 4 Disregard TenGigabitEthernet1 1 1 Disregard TenGigabitEthernet1 1 2 Configure this interface even when operating as 1 G TenGigabitEthernet1 1 3 Configure this interf...

Страница 77: ...not used Table 24 C3850 NM 2 40G Module with 40 G QSFP Module Action Interface Configure this interface FortyGigabitEthernet1 1 1 Configure this interface FortyGigabitEthernet1 1 2 Disregard TenGigabitEthernet1 1 1 Disregard TenGigabitEthernet1 1 2 Disregard TenGigabitEthernet1 1 3 Disregard TenGigabitEthernet1 1 4 Disregard TenGigabitEthernet1 1 5 Disregard TenGigabitEthernet1 1 6 Disregard TenGi...

Страница 78: ...s between the online insertion and removal OIR of network modules Note Procedure Step 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Do not remove the network module with connected cables or installed SFP modules Always remove any cables and modules before you remove the network module Caution A module interface might become error disabled when a network module...

Страница 79: ...nformation about supported SFP and SFP modules refer to the Cisco Transceiver Modules Compatibility Information at http www cisco com en US products hw modules ps5455 products_device_support_tables_list html For information about installing removing cabling and troubleshooting SFP modules see the module documentation that shipped with your device Observe these precautions Class 1 laser product Sta...

Страница 80: ...alled Removing SFP and SFP Modules Procedure Step 1 Attach an ESD preventive wrist strap to your wrist and to an earth ground surface Step 2 Disconnect the cable from the SFP SFP module For reattachment note which cable connector plug is send TX and which is receive RX Step 3 Insert a dust plug into the optical ports of the SFP SFP module to keep the optical interfaces clean Step 4 If the module h...

Страница 81: ...Technical Assistance regarding a network module you need to know its serial number Figure 44 Network Module Serial Number Location Catalyst 3850 Switch Hardware Installation Guide 67 OL 26779 05 Installing a Network Module Finding the Network Module Serial Number ...

Страница 82: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 68 Installing a Network Module Finding the Network Module Serial Number ...

Страница 83: ...one DC module or one module and a blank cover In a NEBS installation you can use two DC modules or one DC module and a blank cover Note All power supply modules have internal fans All switches ship with a blank cover in the second power supply slot The following table describes the supported internal power supply modules Table 26 Power Supply Module Part Numbers and Descriptions Description Part N...

Страница 84: ...put feeds A and B and supports input voltages between 36 and 72 VDC The output voltage range is 51 to 57 V Each AC power supply module has a power cord for connection to an AC power outlet The 1100 W and 715 W modules use a 16 AWG cord only North America All other modules use an 18 AWG cord The DC power supply module must be wired to a DC power source The following illustrations show the power sup...

Страница 85: ...er cord retainer 6 AC OK LED 2 Keying feature 7 PS OK LED 3 AC power cord connector 4 Figure 48 440 W DC Power Supply Grounding terminal 6 440 W DC power supply module 1 Release latch 7 AC OK LED 2 Extraction handle 8 PS OK LED 3 Terminal block safety cover 9 Input power terminals positive polarity 4 Catalyst 3850 Switch Hardware Installation Guide 71 OL 26779 05 Power Supply Installation Power Su...

Страница 86: ...Do not force the power supply or fan module into the slot This can damage the pins on the switch if they are not aligned with the module A power supply that is only partially connected to the switch can disrupt the system operation Remove power from the power supply module before removing or installing the module The power supply is hot swappable In some configurations such as full PoE or power sh...

Страница 87: ...n the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI th...

Страница 88: ...e energize the unit Statement 1028 Warning Step 5 Insert the new power supply into the power supply slot and gently push it into the slot When correctly inserted the 350 W and 715 W power supplies excluding the power cord retainer are flush with the switch rear panel The 1100 W power supply module extends 1 5 inches from the switch rear panel Figure 50 Inserting the AC Power Supply in the Catalyst...

Страница 89: ...d portion of the DC input power source wire extends from the terminal block plug Statement 122 Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Warning This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 20 A Statement 1005 War...

Страница 90: ...ing of the switch in a NEBS installation where the DC supply is the only NEBS compliant power supply option Four leads of 14 gauge copper wire Four fork type terminals from the DC power supply accessory kit The terminals must be the proper size for M3 screws in a Dinkle DT 35 B25 style terminal block Grounding the Switch Follow these steps to install either a single hole ground lug or a dual hole ...

Страница 91: ...faces metallically to OSP wiring Caution Procedure Step 1 Use the ground lug screw and the lug ring for a single ground connection Use the dual hole lug for a ground connection in a NEBS installation Step 2 Strip the 12 gauge or 8 gauge ground wire to 0 5 inch 12 7 mm 0 02 inch 0 5 mm Stripping more than the recommended amount of wire can leave exposed wire from the connector Use 12 gauge copper g...

Страница 92: ...eakers to the OFF position and tape the circuit breaker switches in the OFF position Step 2 Remove the plastic safety cover from the power supply terminal blocks If you are not replacing a DC power supply go to Step 5 Note Step 3 Use a number 2 Phillips screwdriver to remove the DC input power wires from the power terminals Step 4 Press the release latch at the right side of the power supply modul...

Страница 93: ... the terminals Use copper conductors only Statement 1025 Warning Step 2 Using a Panduit crimping tool crimp the fork type terminals to the copper conductor 90C 12 AWG DC power input wires Step 3 Connect the DC input power terminals to the terminal blocks Make sure to match the polarity negative to negative positive to positive when connecting the wires to the terminal blocks Connect the ground wir...

Страница 94: ...onfirm that the power supply DC OK and PS OK LEDs are green Finding the Power Supply Module Serial Number If you contact Cisco Technical Assistance regarding a power supply module you need to know the serial number See the following illustrations to find the serial number You can also use the CLI to find out the serial number Figure 61 1100 W AC Power Supply Serial Number Catalyst 3850 Switch Hard...

Страница 95: ... Serial Number Figure 63 440 W DC Power Supply Serial Number Figure 64 750 W AC Power Supply Serial Number Catalyst 3850 Switch Hardware Installation Guide 81 OL 26779 05 Power Supply Installation Finding the Power Supply Module Serial Number ...

Страница 96: ... W AC Power Supply Serial Number Figure 66 750 W DC Power Supply Serial Number Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 82 Power Supply Installation Finding the Power Supply Module Serial Number ...

Страница 97: ...powered switch should always have more than one operational fan The switch can operate with two operational fans and one nonfunctional fan but the failed fan should be replaced as soon as possible to avoid a service interruption due to a second fan fault Figure 67 Fan Module for WS C3850 Switches Retainer clip 3 Fan LED 1 Extraction handles 4 Exhaust vent 2 The WS C3850 switches require three fans...

Страница 98: ...ation Guidelines Observe these guidelines when removing or installing a fan module Do not force the fan module into the slot This can damage the pins on the switch if they are not aligned with the module A fan module that is only partially connected to the switch can disrupt the system operation The switch supports hot swapping of the fan module You can remove and replace the module without interr...

Страница 99: ...S switches will depend on the power supply and fans installed Ensure that the power supplies are inserted correctly to match the corresponding fans Power supplies with blue handles correspond to fans with blue handles and power supplies with red handles correspond to fans with red handles For power supplies and fans with red handles airflow is from the front panel to the rear panel warm air is pul...

Страница 100: ...ou need to know the fan module serial number See the following illustration to find the serial number Figure 70 Fan Single Module Serial Number Figure 71 Fan Double Module Serial Number Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 86 Installing the Fan Finding the Fan Module Serial Number ...

Страница 101: ...nce It comes with the default image so there is no need to enable anything or install any license on the device You can use WebUI to build configurations and to monitor and troubleshoot the device without having CLI expertise Connecting to the Switch Before you begin The bootup script runs the configuration wizard which prompts you for basic configuration input Would you like to enter the initial ...

Страница 102: ... your device and prevent unauthorized users from seeing your network configuration or manipulating your settings Procedure Step 1 Log on using the default username and password provided with the device The default username is cisco the default password is the serial number of the switch chassis Step 2 Set a password of up to 25 alphanumeric characters The username password combination you set give...

Страница 103: ...Figure 72 Create Account Catalyst 3850 Switch Hardware Installation Guide 89 OL 26779 05 Configuring the Switch Creating User Accounts ...

Страница 104: ...ettings page configure the following information Procedure Step 1 In the Device ID and Location Settings section type a unique name to identify your device in the network Step 2 Choose the date and time settings for your device To synchronize your device with a valid outside timing mechanism such as an NTP clock source choose Automatic or choose Manual to set it yourself Catalyst 3850 Switch Hardw...

Страница 105: ...6 To enable secure remote access to the device using Secure Shell SSH check the SSH check box Step 7 Check the VTP transparent mode check box to disable the device from participating in VTP If you did not select Wired Network in the earlier step continue to the next screen to verify your configuration on the Day 0 Config Summary screen and click Finish To automatically configure your device based ...

Страница 106: ...ration tasks and save time choose a site profile based on where your device may be installed and managed in your network Based on the site profile you choose your device is automatically Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 92 Configuring the Switch Configuring Your Device Based on a Site Profile ...

Страница 107: ...parent Mode Transparent Mode Transparent VTP Enabled Enabled Enabled UDLD Recovery mode set to Auto Recovery mode set to Auto Recovery mode set to Auto Error Disable Recovery Source Destination IP Source Destination IP Source Destination IP Port Channel Load Balance Version 2 Version 2 Version 2 SSH Enabled Enabled Enabled SCP Enabled Enabled Enabled VTY Access to Switch Enabled Enabled Enabled Se...

Страница 108: ... ports configured as Port channel in trunk mode set to allow all VLANs Selected ports configured as Port channel in trunk mode set to allow all VLANs Selected uplink interfaces configured as trunk ports set to allow all VLANs Uplink Interfaces Downlink ports configured in Access mode Downlink ports configured in Access mode Downlink ports configured in Access mode Downlink Interfaces Port channel ...

Страница 109: ...Figure 75 Site Profile Access Switches Catalyst 3850 Switch Hardware Installation Guide 95 OL 26779 05 Configuring the Switch Configuring Your Device Based on a Site Profile ...

Страница 110: ... Switch Single Port Channel Downlink Single Distribution Switch Single Downlink Setting The hostname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup Hostname Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 96 Configuring the Switch Configuring Your Device ...

Страница 111: ...ent VLAN VLAN Layer 3 settings configured on the management port based on Quick Setup Layer 3 settings configured on the management port based on Quick Setup Layer 3 settings configured on the management port based on Quick Setup Management Interface QoS Policy for Distribution defined QoS Policy for Distribution defined QoS Policy for Distribution defined QoS Policy Selected uplink ports connect ...

Страница 112: ...Figure 77 Site Profile Distribution Switches Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 98 Configuring the Switch Configuring Your Device Based on a Site Profile ...

Страница 113: ...h ECMP Peer and Port Channel Downlink Standalone Core Switch with ECMP Peers Setting The hostname or device name you provided as part of Quick Setup The hostname or device name you provided as part of Quick Setup Hostname Enabled Enabled UDLD Catalyst 3850 Switch Hardware Installation Guide 99 OL 26779 05 Configuring the Switch Configuring Your Device Based on a Site Profile ...

Страница 114: ...n the management port based on Quick Setup Layer 3 settings configured on the management port based on Quick Setup Management Interface QoS Policy for Distribution Core defined QoS Policy for Distribution Core defined QoS Policy Selected uplink ports connect to MAN WAN device Selected uplink ports connect to MAN WAN device Uplink Interfaces Downlink connections to distribution switches Downlink co...

Страница 115: ...Configuring VLAN Settings Procedure Step 1 In the VLAN Configuration section you can configure both data and voice VLANs Type a name for your data VLAN Catalyst 3850 Switch Hardware Installation Guide 101 OL 26779 05 Configuring the Switch Configuring Switch Wide Settings ...

Страница 116: ...and assign a VLAN ID to it If you are creating several VLANs indicate a VLAN range Configure STP Settings Procedure Step 1 RPVST is the default STP mode configured on your device You can change it to PVST from the STP Mode drop down list Step 2 To change a bridge priority number from the default value 32748 change Bridge Priority to Yes and choose a priority number from the drop down list Catalyst...

Страница 117: ...ter a domain name that the software uses to complete unqualified hostnames Step 2 Type an IP address to identify the DNS server This server is used for name and address resolution on your device Catalyst 3850 Switch Hardware Installation Guide 103 OL 26779 05 Configuring the Switch Configuring DHCP NTP DNS and SNMP Settings ...

Страница 118: ... date and timezone enter the IP address of the NTP server with which you want to synchronize the device time Step 6 In the Management Details section type an IP address to identify the SNMP server SNMPv1 SNMPv2 and SNMPv3 are supported on your device Step 7 Specify the SNMP community string to permit access to the SNMP protocol Figure 81 DHCP NTP DNS and SNMP Settings Catalyst 3850 Switch Hardware...

Страница 119: ...rds the core of the network Downlink For connecting to devices further down in the network topology Access For connecting guest devices that are VLAN unaware Step 2 Choose an option from the Select Switch drop down list Step 3 Make selections from the Available list of interfaces based on how you want to enable them and move them to the Enabled list Catalyst 3850 Switch Hardware Installation Guide...

Страница 120: ... 82 Port Settings What to do next Click Day 0 Config Summary to verify your setup Click Finish Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 106 Configuring the Switch Configuring Port Settings ...

Страница 121: ...he CLI on a configured or unconfigured switch by connecting the RJ 45 console port or USB console port of the switch to your PC or workstation and accessing the switch through a terminal emulation program Catalyst 3850 Switch Hardware Installation Guide 107 OL 26779 05 Configuring the Switch Configuring the Switch Using the CLI ...

Страница 122: ...te and character format of the PC or terminal to match the console port default characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Step 4 Power on the switch as described in the switch getting started guide Step 5 The PC or terminal displays the bootloader sequence Press Enter to display the setup prompt Connecting the USB Console Port Procedure Step 1 If you are connecti...

Страница 123: ...ting the USB Console Cable to the Switch Figure 85 Connecting the USB Console Cable to the Switch Catalyst 3850 Switch Hardware Installation Guide 109 OL 26779 05 Configuring the Switch Connecting the USB Console Port ...

Страница 124: ...Plus makes communication between the switch and your PC or terminal possible Step 4 Configure the baud rate and character format of the PC or terminal to match the console port default characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Step 5 Power on the switch as described in the switch getting started guide Step 6 The PC or terminal displays the bootloader sequence Pre...

Страница 125: ...Step 5 The InstallShield Wizard Completed window appears Click Finish Step 6 Connect the USB cable to the PC and the switch console port The USB console port LED turns green and the Found New Hardware Wizard appears Follow the instructions to complete the driver installation Installing the Cisco Microsoft Windows 2000 USB Driver Procedure Step 1 Obtain the Cisco USB console driver file from the Ci...

Страница 126: ... the Found New Hardware Wizard appears Follow the instructions to complete the driver installation Uninstalling the Cisco Microsoft Windows USB Driver Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver Use the Windows Add or Remove Programs utility or the setup exe file Using the Setup exe Program Before you begin Disconnect the switch console terminal before uninstalling the driver P...

Страница 127: ...ows 32 bit or setup x64 exe for Windows 64bit Click Next Step 2 The InstallShield Wizard for Cisco Virtual Com appears Click Next Step 3 When the Program Maintenance window appears select the Remove radio button Click Next Step 4 When the Remove the Program window appears click Remove If a User Account Control warning appears click Allow I trust this program to proceed Note Step 5 When the Install...

Страница 128: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 114 Configuring the Switch Uninstalling the Cisco Microsoft Windows Vista and Windows 7 USB Driver ...

Страница 129: ... the LED colors and their meanings Switch Connections Bad or Damaged Cable Always examine the cable for marginal damage or failure A cable might be just good enough to connect at the physical layer but it could corrupt packets as a result of subtle damage to the wiring or connectors You can identify this situation because the port has many packet errors or the port constantly flaps loses and regai...

Страница 130: ...t have encountered physical stress that causes it to function at a marginal level If the port LED does not turn on Connect the cable from the switch to a known good device Ensure that both ends of the cable are connected to the correct ports Verify that both devices have power Verify that you are using the correct cable type Check for loose connections Sometimes a cable appears to be seated but is...

Страница 131: ...n Reenable the port if needed Make sure that all fiber optic connections are properly cleaned and securely connected When you insert several SFPs in multiple switch ports wait for 5 seconds between inserting each SFP This will prevent the ports from going into error disabled mode Similarly when you remove an SFP from a port wait for 5 seconds before reinserting it Interface Settings Verify that th...

Страница 132: ...twork Interface Cards Problems sometimes occur between the switch and third party network interface cards NICs By default the switch ports and interfaces autonegotiate Laptops or other devices are commonly set to autonegotiate yet sometimes autonegotiation issues occur To troubleshoot autonegotiation problems try manually setting both sides of the connection If this does not solve the problem ther...

Страница 133: ... be a Catalyst 3850 switch Step 2 Power down the failed switch Remove AC or DC input power and if the switch is part of a StackPower stack remove the StackPower cables Step 3 Make sure the replacement switch is powered off and then connect it to the stack If you had manually set the member numbers for the switch stack manually assign the member number of the failed switch to the replacement switch...

Страница 134: ...Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 120 Troubleshooting Replacing a Failed Data Stack Member ...

Страница 135: ... 40 to 70 C Storage temperature 5 to 95 noncondensing Relative humidity Up to 10 000 ft 3000 m Operating altitude Up to 15 000 ft 4500 m Storage altitude 14 Minimum ambient temperature for cold start is 32 F 0 C This table describes the environmental specifications Table 32 Environmental Specifications for the Power Supplies Environmental Ranges AC power supply 23 to 113 F 5 to 45 C DC power suppl...

Страница 136: ...non PoE switches 14 2 lb 6 5 kg Catalyst 3850 48 port non PoE switches 14 4 lb 6 5 kg Catalyst 3850 48 port PoE switches 12 4 lb 5 7 kg WS C3850 24S and WS C3850 12S switches 12 9 lb 5 8 kg WS C3850 12XS switches 13 5 lb 6 1 kg WS C3850 24XS switches 16 42 lb 7 45 kg WS C3850 48XS switches This table describes the physical specifications Table 34 Physical Specifications for the Power Supplies Weig...

Страница 137: ... 14 28 in 40 1 mm X 54 6 mm X 362 7 mm PWR C3 750WDC F Specifications for the Power Supplies Switches and Fan Table 35 Power Specifications for the AC Power Power Requirements PWR C1 1100WAC 1100 W PWR C1 715WAC 715 W PWR C1 350WAC 350 W PWR C3 750WAC R 750 W PWR C3 750WAC F 750 W Maximum output power PWR C1 1100WAC 1100 W 115 to 240 VAC autoranging 50 60 Hz PWR C1 715WAC 715 W 100 to 240 VAC auto...

Страница 138: ...r nominal 1365 BTU hour max PWR C3 750WAC F 1122 BTU hour nominal 1365 BTU hour max Total output BTU16 15 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch The BTU ratings are based on 100 VAC for the 350 W and 715 W power supplies and 115 VAC for the 1100 W power supply 16 The total input and total output BTU ratings refer to inpu...

Страница 139: ... VDC nominal 55 VDC to 72 VDC PWR C3 750WDC F 60 VDC nominal 55 VDC to 72 VDC Voltage range international PWR C1 440WDC 1841 BTUs per hour 540 W Total input BTU17 PWR C1 440WDC 1502 BTUs per hour 440 W Total output BTU 1 PWR C1 440WDC 12 AWG or 8 AWG Wire gauge for ground connection PWR C1 440WDC 20 A Branch circuit protection 17 The total input and total output BTU ratings refer to input power to...

Страница 140: ...0 cfm Airflow Table 38 Fan Module Environmental and Physical Specifications for Catalyst WS C3850 48XS Switch Models Environmental Ranges 50 to 104 F 10 to 40 C Operating temperature 8 to 80 noncondensing Relative humidity 50 to 6500 feet 16 to 1981 meters Altitude Physical Specification 2 25 x 7 00 x 8 50 in 5 72 x 17 78 x 21 59 cm Dimensions H x D x W 0 7 lb 0 32 kg Weight Catalyst 3850 Switch H...

Страница 141: ...ables and Adapters on page 129 Connector Specifications 10 100 1000 Ports Including PoE All 10 100 1000 ports use standard RJ 45 connectors and Ethernet pinouts Figure 86 10 100 1000 Port Pinouts SFP Module Connectors Figure 87 Duplex LC Cable Connector Catalyst 3850 Switch Hardware Installation Guide 127 OL 26779 05 ...

Страница 142: ...ont panel and an RJ 45 console port on the rear panel Figure 91 USB Mini Type B Port The USB console port uses a USB Type A to 5 pin mini Type B cable The USB Type A to USB mini Type B cable is not supplied You can order an accessory kit part number 800 33434 that contains this cable Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 128 Connector and Cable Specifications Console Port ...

Страница 143: ... Table 39 StackWise Cables Minimum Bend Radius and Coiled Diameter MinimumCoiledDiameter Minimum Bend Radius Cable Length Cable Part Number 5 20 in 132 mm 2 60 in 66 mm 1 64 feet 0 5 m STACK T1 50CM 5 20 in 132 mm 2 60 in 66 mm 3 28 feet 1 0 m STACK T1 1M 7 17 in 182 mm 3 58 in 91 mm 9 84 feet 3 0 m STACK T1 3M 5 20 in 132 mm 2 60 in 66 mm 1 64 feet 0 5 m STACK T2 50CM 5 20 in 132 mm 2 60 in 66 mm...

Страница 144: ...SFP or SFP transceiver modules that are currently supported Cisco SFP 10G SR Cisco 10GBASE SR SFP Module for Multimode Fiber Cisco SFP 10G SR S module S Class Cisco 10GBASE SR SFP Module for Multimode Fiber Cisco SFP 10G LR Cisco 10GBASE LR SFP Module for Single Mode Fiber Cisco SFP 10G LR S module S Class Cisco 10GBASE LR SFP Module for Single Mode Fiber Cisco SFP 10G ER Cisco 10GBASE ER SFP Modu...

Страница 145: ...e outside of the left plug should be a different color from the wire connected to the pin on the inside of the right plug Figure 97 Identifying a Crossover Cable Console Port Adapter Pinouts The RS 232 console port uses an 8 pin RJ 45 connector Use an RJ 45 to DB 9 adapter cable to connect the switch console port to a console PC You need to provide a RJ 45 to DB 25 female DTE adapter to connect th...

Страница 146: ...D TxD 3 RxD DTR 4 DSR RTS 7 CTS Table 41 Console Port Signaling with a DB 25 Adapter Console Device RJ 45 to DB 25 Terminal Adapter Switch Console Port DTE Signal DB 25 Pin Signal CTS 5 RTS DSR 6 DTR RxD 3 TxD GND 7 GND GND 7 GND TxD 2 RxD DTR 20 DSR RTS 4 CTS Catalyst 3850 Switch Hardware Installation Guide OL 26779 05 132 Connector and Cable Specifications Connector and Cable Specifications ...

Отзывы: