B-5
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
OL-19593-01
Appendix B Connector and Cable Specifications
Cable and Adapter Specifications
The RJ-45 console port uses an 8-pin RJ-45 connector (See
Table B-2
and
Table B-3
.) The supplied
RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need
to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a
terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter. For console port
and adapter pinout information, see
Table B-2
and
Table B-3
.
Cable and Adapter Specifications
•
SFP and SFP+ Module Cable Specifications, page B-5
•
SFP and SFP+ Module Cable Specifications, page B-5
•
Four Twisted-Pair Cable Pinouts, page B-7
•
Two Twisted-Pair Cable Pinouts, page B-7
•
Identifying a Crossover Cable, page B-8
•
Console Port Adapter Pinouts, page B-8
SFP and SFP+ Module Cable Specifications
Each port must match the wave-length specifications on each end of the cable, and the cable must not
exceed the stipulated cable length. Copper 1000BASE-T SFP module transceivers use standard four
twisted-pair, Category 5 cable at lengths up to 328 feet (100 meters).
Table B-1
Fiber-Optic SFP and SFP+ Module Port Cabling Specifications
SFP Module
Wavelength
(nanometers)
Cable Type
Core
Size/Cladding
Size (micron)
Modal
Bandwidth
(MHz/km)
1
Cable Distance
100BASE-BX
(GLC-FE-100BX-D
GLC-FE-100BX-U)
1310 TX
1550 RX
SMF
G.652
2
—
32,810 feet (10 km)
100BASE-FX
(GLC-GE-100FX)
1310
MMF
50/125
62.5/125
500
500
6,562 feet (2 km)
6,562 feet (2 km)
100BASE-FX
(GLC-FE-100FX)
1310
MMF
50/125
62.5/125
500
500
6,562 feet (2 km)
6,562 feet (2 km)
100BASE-LX
(GLC-FE-100LX)
1310
SMF
G.652
2
—
32,810 feet (10 km)
1000BASE-BX10-D
(GLC-BX-D)
1490 TX
1310 RX
SMF
G.652
2
—
32,810 feet (10 km)
1000BASE-BX10-U
(GLC-BX-U)
1310 TX
1490 RX
SMF
G.652
2
—
32,810 feet (10 km)
1000BASE-SX
(GLC-SX-MM)
850
MMF
62.5/125
62.5/125
50/125
50/125
160
200
400
500
722 feet (220 m)
902 feet (275 m)
1,640 feet (500 m)
1,804 feet (550 m)