29-12
Catalyst 2928 Switch Software Configuration Guide
OL-23389-01
Chapter 29 Configuring SNMP
Configuring SNMP
Note
Many commands use the word
traps
in the command syntax. Unless there is an option in the command
to select either traps or informs, the keyword
traps
refers to either traps, informs, or both. Use the
snmp-server host
global configuration command to specify whether to send SNMP notifications as
traps or informs.
describes the supported switch traps (notification types). You can enable any or all of these
traps and configure a trap manager to receive them.
Table 29-5
Switch Notification Types
Notification Type
Keyword
Description
bridge
Generates STP bridge MIB traps.
cluster
Generates a trap when the cluster configuration changes.
config
Generates a trap for SNMP configuration changes.
copy-config
Generates a trap for SNMP copy configuration changes.
entity
Generates a trap for SNMP entity changes.
envmon
Generates environmental monitor traps. You can enable any or all of these
environmental traps: fan, shutdown, status, supply, temperature.
errdisable
Generates a trap for a port VLAN errdisabled. You can also set a maximum
trap rate per minute. The range is from 0 to 10000; the default is 0, which
means there is no rate limit.
flash
Generates SNMP FLASH notifications.
hsrp
Generates a trap for Hot Standby Router Protocol (HSRP) changes.
ipmulticast
Generates a trap for IP multicast routing changes.
mac-notification
Generates a trap for MAC address notifications.
msdp
Generates a trap for Multicast Source Discovery Protocol (MSDP) changes.
ospf
Generates a trap for Open Shortest Path First (OSPF) changes. You can enable
any or all of these traps: Cisco specific, errors, link-state advertisement, rate
limit, retransmit, and state changes.
pim
Generates a trap for Protocol-Independent Multicast (PIM) changes. You can
enable any or all of these traps: invalid PIM messages, neighbor changes, and
rendezvous point (RP)-mapping changes.
port-security
Generates SNMP port security traps. You can also set a maximum trap rate
per second. The range is from 0 to 1000; the default is 0, which means that
there is no rate limit.
rtr
Generates a trap for the SNMP Response Time Reporter (RTR).
snmp
Generates a trap for SNMP-type notifications for authentication, cold start,
warm start, link up or link down.
storm-control
Generates a trap for SNMP storm-control. You can also set a maximum trap
rate per second. The range is from 0 to 1000; the default is 0 (no limit is
imposed; a trap is sent at every occurrence).
stpx
Generates SNMP STP Extended MIB traps.
syslog
Generates SNMP syslog traps.
Содержание Catalyst 2928
Страница 28: ...Contents xxviii Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...
Страница 32: ...xxx Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Preface ...
Страница 496: ...26 14 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 26 Configuring SPAN Displaying SPAN Status ...
Страница 534: ...29 18 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 Chapter 29 Configuring SNMP Displaying SNMP Status ...
Страница 700: ...Index IN 36 Catalyst 2928 Switch Software Configuration Guide OL 23389 01 ...