background image

Drive removed from drive tray

2

Drive tray screws ( two on each side)

1

Step 3

Install a new drive:

a) Place a new drive in the empty drive tray and install the four drive-tray screws.
b) With the ejector lever on the drive tray open, insert the drive tray into the empty drive bay.
c) Push the tray into the slot until it touches the backplane, and then close the ejector lever to lock the drive in place.

Remove and Replace a Power Supply

Two power supplies ship with the chassis; they are redundant and hot-swappable. One is the active power
supply and the other is the standby power supply (1+1).

The C195 ships with one power supply, but you can add another one for redundancy.

Note

The chassis also supports cold redundancy. Depending on the power being drawn by the chassis, one power
supply might actively provide all power to the system while the remaining power supply is put into a standby
state. For example, if the power consumption can be satisfied by power supply 1, then power supply 2 is put
into a standby state.

When you replace power supplies, do not mix power supply types in the chassis. Both power supplies must
be the same wattage and Cisco PID.

Caution

Power supply health monitoring notifies you if the power supply loses power or malfunctions so that redundancy
is lost. Check the power supply cables to make sure they are functioning. If they are and errors are still
occurring, replace the power supply.

Trouble

Before you begin

Take note of the following warnings:

Statement 1018—

Supply Circuit

To reduce risk of electric shock and fire, take care when connecting units to the supply circuit so that wiring
is not overloaded.

Warning

Maintenance and Upgrade

7

Maintenance and Upgrade

Remove and Replace a Power Supply

Содержание C195

Страница 1: ...t in the chassis To completely remove power as directed in some maintenance procedures you must disconnect all power cords from all power supplies in the chassis Caution You can shut down the chassis using the front panel Power button or software management Step 1 Check the Power LED Amber The chassis is already in standby mode and you can safely remove power Green The chassis is in main power mod...

Страница 2: ...cycle chassis power you must have a third party tool that supports the Intelligent Platform Management Interface IPMI version 2 0 Step 1 Use SSH or the serial console port to access the CLI Step 2 Log in using an account with Administrator access Step 3 Enter the following commands remotepower setup Step 4 Follow the prompts to specify the following The dedicated IP address for the RPC port netmas...

Страница 3: ... 2 for more information Note For example issue the following command from a UNIX computer with IPMI support ipmitool I lan H ip address U remoteresetuser P password chassis power reset Step 2 Wait at least 11 minutes for the chassis to reboot Install Uninstall the Locking Faceplate The locking faceplate Cisco part number 74 115098 01 for a 1 RU chassis and Cisco part number 74 115099 01 for a 2 RU...

Страница 4: ...y push in as the faceplate is installed Step 3 Lock the faceplate using the key that shipped with the faceplate Step 4 To uninstall the faceplate unlock the faceplate push the latch to the right and pull the faceplate out Remove and Replace a Drive The drives are hot swappable You do not have to shut down the chassis to remove or replace drives Note Maintenance and Upgrade 4 Maintenance and Upgrad...

Страница 5: ...nd conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Warning Statement 1030 Equipment Installation Only trained and qualified personnel should be allowed to install replace or service this equipment Warning Statement 1073 No User Serviceable Parts No serviceable parts inside To avoid risk of electric shock ...

Страница 6: ... 2 Ejector handle 1 Step 2 Remove the four drive tray screws that secure the drive to the tray and then lift the drive out of the tray Figure 3 Remove the Drive Tray Maintenance and Upgrade 6 Maintenance and Upgrade Remove and Replace a Drive ...

Страница 7: ...assis one power supply might actively provide all power to the system while the remaining power supply is put into a standby state For example if the power consumption can be satisfied by power supply 1 then power supply 2 is put into a standby state When you replace power supplies do not mix power supply types in the chassis Both power supplies must be the same wattage and Cisco PID Caution Power...

Страница 8: ...e Parts No serviceable parts inside To avoid risk of electric shock do not open Warning Statement 1074 Comply with Local and National Electrical Codes To reduce risk of electric shock or fire installation of the equipment must comply with local and national electrical codes Warning Step 1 Remove the power supply that you are replacing or the blank panel from an empty bay a Do one of the following ...

Страница 9: ...e and insert the new power supply into the empty bay b Push the power supply into the bay until the release lever locks c Connect the power cord to the new power supply d If you shut down the chassis press the Power button to return it to main power mode Maintenance and Upgrade 9 Maintenance and Upgrade Remove and Replace a Power Supply ...

Страница 10: ...Maintenance and Upgrade 10 Maintenance and Upgrade Remove and Replace a Power Supply ...

Отзывы: