background image

• UNI conformant to ATM Forum UNI Specification V.3.1,

ITU-T I.361 and I.432 specifications

• Support for ATM Forum ILMI 4.0

• Complies with standard Usage Parameter Control (UPC) per

ATM Forum UNI Specification V.3.1, TM 4.0 and ITU-T I.371

• Supports virtual circuit connections (VCCs) and virtual path

connections (VPCs) per ATM Forum UNI Specification V.3.1

and ITU-T I.371

• Connections:

– 16,384 to 32,768 connections per card per UNI Specification

3.1

• Virtual path identifier (VPI)/virtual channel identifier (VCI)

range for VCCs and VPCs: per UNI Specification V.3.1

• Support for VC merging with future software upgrade

(enhanced -E and -EX models only)

Traffic Management

• Per-VC queuing and scheduling

• Per-VC traffic shaping

• Per-VC weighted fair queuing (WFQ)

• Up to 16 classes of service with the following configurable

parameters:

– Separate cell discard threshold for CLP0 and CLP1 cells

– Separate early packet discard (EPD) threshold for CLP0 and

CLP1 cells with future software upgrade (enhanced -E and

-EX models only)

– Maximum Queue Depth (MQD) with partial packet discard

(PPD)

– Service Priority Level (SPL)

– Explicit Forward Congestion Indication (EFCI) threshold

Constant Bit Rate Service

• UPC per ATM Forum UNI Specification V.3.1, TM V.4.0 and

ITU-T I.371

• UPC: Ingress rate monitoring and discarding for:

– Peak Cell Rate (PCR)

– Cell Delay Variation Tolerance (CDVT)

Variable Bit Rate Service

• UPC per ATM Forum UNI Specification V.3.1, TM V.4.0 and

ITU-T I.371

• UPC: Ingress rate monitoring and cell tagging for:

– PCR

– CDVT

– Sustainable Cell Rate (SCR)

– Maximum Burst Size (MBS)

• CLP tagging, enabled, or disabled on a per-virtual circuit (VC)

basis at the ingress side

• Support for both VBR-rt and VBR-nrt

• EPD

ABR Service and Congestion Control

• VS/VD per ATM Forum Traffic Management

Specification V.4.0

• Explicit Rate (ER) stamping

• EFCI tagging monitoring

• ForeSight

®

• Support for non-AAL5 traffic (enhanced -E and -EX models

only)

ABR VS/VD

• VS and VD resource management (RM) cell generation and

termination

• Virtual connection queue (VCQ) assigned to each VC ingress

• VCQ configurable parameters:

– Separate cell discard threshold for CLP0 and CLP1 cells

– EPD threshold

– Maximum queue depth with PPD

– Reserved buffer space for RM cells

• Support for UBR and VBR access

• Interworking with ForeSight

®

(enhanced -E and -EX models

only)

Unspecified Bit Rate Service

• UPC per ATM Forum UNI Specification V.3.1, TM V.4.0 and

ITU-T I.371

• Minimum cell rate configurable and guaranteed

• EPD

Virtual Trunks

• Support for up to 31 virtual trunks per card, each with 16

class-of-service queues

• UNI and NNI option for the interface with public ATM network

• Per virtual trunk traffic shaping

• Reconfigurable maximum trunk rate

Содержание BPX-BXM-T3-12

Страница 1: ...k platform that can deliver an unprecedented level of scalability performance and functionality at lower costs Such an ATM switching platform must support high speed interfaces with high port densities as well as advanced ATM traffic management capability Advanced ATM traffic management capabilities are implemented in a family of custom ASICs that enable high density high speed ATM interface modul...

Страница 2: ...d ITU T I 371 UPC Ingress rate monitoring and discarding for Peak Cell Rate PCR Cell Delay Variation Tolerance CDVT Variable Bit Rate Service UPC per ATM Forum UNI Specification V 3 1 TM V 4 0 and ITU T I 371 UPC Ingress rate monitoring and cell tagging for PCR CDVT Sustainable Cell Rate SCR Maximum Burst Size MBS CLP tagging enabled or disabled on a per virtual circuit VC basis at the ingress sid...

Страница 3: ...1 E 164 NSAP addressing per ATM Forum UNI Specification V 3 1 Support for Private Network Network Interface PNNI per ATM Forum PNNI Specification V 1 0 Fault Management and Reporting Compliant with Bellcore GR 253 CORE Alarms Loss of Signal LOS Loss of Pointer LOP Loss of Frame LOF Loss of Cell Delineation LOC Alarm Indication Signal AIS Remote Defect Indication RDI Alarm integration up down count...

Страница 4: ...arm LED Red Card Active Standby Fail Port Active and OK Active remote alarm Active local alarm Product Number Enhanced Model Number of Ports per Card Ingress Cell Buffer cells Egress Cell Buffer cells Number of Connections per Card VC Merge Capable BXM T3 8 BXM E3 8 8 102 400 102 400 16 384 32 768 BXM T3 12 BXM E3 12 12 133 120 235 520 16 384 32 768 BXM T3 8E BXM E3 8E Yes 8 256 000 256 000 16 384...

Страница 5: ...many Greece Hong Kong Hungary India Indonesia Ireland Israel Italy Japan Korea Luxembourg Malaysia Mexico The Netherlands New Zealand Norway Peru Philippines Poland Portugal Puerto Rico Romania Russia Saudi Arabia Singapore Slovakia Slovenia South Africa Spain Sweden Switzerland Taiwan Thailand Turkey Ukraine United Kingdom United States Venezuela Corporate Headquarters Cisco Systems Inc 170 West ...

Отзывы: