29-8
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.30, Part Number 78-12907-01 Rev. E0, May 2005
Chapter 29 Replacing Parts
Replacing an AC Power Supply
Step 8
There are two power supply securing fasteners, one on each side of the power supply assembly
(Figure 29-4). The one on the left of each supply is a spring-loaded pin, the one on the right of each
supply is a normal thumb-screw. Loosen the thumb-screw on the right.
Step 9
With the right hand, grip the power supply under the front panel. With the left hand, pull out the
spring-loaded pin on the left side of the supply and hold it out as you pull out the power supply assembly.
Step 10
The power supply assembly weighs approximately 15 pounds (33 Kgs.). Support the bottom of the power
supply as you pull it straight out, until it is free of the shelf.
Field-Installing a Second AC Power Supply
To field-install a redundant power supply, use the following procedure:
Step 1
If the front Air Intake Grille has already been removed, go to the next step. If not, remove it using
Step 2 through Step 6 of the previous procedure.
Step 2
If converting a node from single to redundant powering, first remove the blank filler panel over position
B (right side). With Air Intake Grille open, remove three screws attaching the filler panel to the retainer
bracket (see Figure 29-5).
Figure 29-5 Removing Blank Filler Panel (B side shown)
Step 3
Slide a replacement power supply assembly into the tracks of the power supply shelf.
Step 4
When the power supply is completely seated, the spring-loaded pin will snap into place to assure that
the power supply has mated with its connector.
Filter panel
(B side)
Latch
H8036
Содержание BPX 8650
Страница 49: ...P A R T 1 The BPX Switch ...
Страница 50: ......
Страница 159: ...P A R T 2 Installation ...
Страница 160: ......
Страница 273: ...P A R T 3 Initial Configuration and Network Management ...
Страница 274: ......
Страница 311: ...P A R T 4 Configuring Connections ...
Страница 312: ......
Страница 487: ...P A R T 5 Troubleshooting and Maintenance ...
Страница 488: ......
Страница 533: ...P A R T 6 BPX Specifications ...
Страница 534: ......
Страница 555: ...P A R T 7 Appendices ...
Страница 556: ......