17
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of
a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if
you are uncertain that suitable grounding is available.
Statement 1024
Warning
This unit might have more than one power supply connection. All connections must be removed to de-energize the
unit.
Statement 1028
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: AC power supplies 20 A and DC power supplies 40 A.
Statement 1005
Figure 12
shows the ASR1006-PWR-DC power supply.
Figure 12
Cisco ASR 1006 Router DC Power Supply (ASR1006-PWR-DC)
Figure 13
shows the ASR1013/06-PWR-DC power supply.
1
Fan
6
DC power supply grounding lugs
2
DB-25 alarm connector
7
Power supply captive screw
3
Tie-wrap tab Power supply ground lugs
8
Power supply handle
4
DC Power supply terminal and plastic cover
9
Power supply ON/OFF (I/O) circuit breaker switch
5
Earth grounding symbol
10
DC power supply LEDs
OFF
280023
OUTPUT INPUT
INPUT
FAIL
OK
OK
ALARMS
60V
1A MAX
This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
-48/-60V 40A
55
2
1
4
5
3
6
7
8
9
10