AC power supply captive installation screw
6
AC power supply slot number 0
2
AC power supply slot number 1
7
AC power supply On (|)/Off (O) switch
3
AC power inlet
8
AC power supply LEDs
4
The following imave shows the Cisco ASR 1002-X Router DC power supply.
Figure 3: Cisco ASR 1002-X Router DC Power Supply
DC power supply captive installation screw
6
Chassis ESD socket
1
DC power supply slot 1 label
7
DC power supply slot 0 label
2
Ground lead
8
DC power supply switch Standby/On (|)
3
Positive lead
9
DC power supply LEDs
4
Negative lead
10
Power supply fan
5
Internal fans draw cooling air into the chassis and across internal components to maintain an acceptable
operating temperature. The fans are located at the rear of the chassis. A two-hole grounding lug is located on
the side of the chassis. Two power supplies, either two AC power supplies or two DC power supplies, can be
accessed from the rear of the router.
Use only the AC power supplies or the DC power supplies in the Cisco ASR 1002-X Router. Do not mix
power supply types.
Caution
Cisco ASR 1002-X Router Slot Numbering
The Cisco ASR 1002-X Router contains an integrated SIP that supports three half-height SPAs or one
half-height SPA and one full-height SPA. The SPA bays are Bay 1, Bay 2, and Bay 3. The router provides a
built-in 6 Gigabit Ethernet interface, and this SPA is physically located on the integrated route processor
board. The built-in 6xGE SPA ports are located in the SPA Bay 0 and addressed as GE 0/0/x.
The following image shows the Cisco ASR 1002-X Router slot numbering.
Cisco ASR 1002-X Router Overview and Installation
4
Cisco ASR 1002-X Router Overview and Installation
Cisco ASR 1002-X Router Slot Numbering