5-4
Cisco ASR 1000 Series Aggregation Services Routers SIP and SPA Hardware Installation Guide
OL-14126-03
Chapter 5 Installing and Removing a SIP
Online Insertion and Removal
Router#
show platform
Chassis type: ASR1006
Slot Type State Insert time (ago)
--------- ------------------- --------------------- -----------------
0 ASR1000-SIP10 ok 2d20h
0/0 SPA-1XOC12-POS ok 2d20h
0/1 SPA-1XOC12-POS ok 1d21h
0/2 SPA-5X1GE-V2 ok 2d20h
0/3 SPA-4XOC3-POS-V2 ok 2d20h
1 ASR1000-SIP10 disabled 1d23h
R0 ASR1000-RP1 ok, active 1w3d
F0 ASR1000-ESP10 ok, active 1w3d
P0 Unknown ps, fail never
P1 Unknown ps, fail never
Slot CPLD Version Firmware Version
--------- ------------------- ---------------------------------------
0 06120701 12.2(20071009:051408) [gschnorr-mcp_...
1 07091401 12.2(20070807:170946) [gschnorr-mcp_...
R0 07010515 12.2(33r)XN2
F0 07021400 12.2(20071030:180953) [gschnorr-mcp_...
To verify activation and proper operation of a SIP, enter the
show platform
command and observe “ok”
in the State field as shown in the following example:
Router#
show platform
Chassis type: ASR1006
Slot Type State Insert time (ago)
--------- ------------------- --------------------- -----------------
0 ASR1000-SIP10 ok 03:19:46
0/0 SPA-5X1GE-V2 ok 03:18:28
0/1 SPA-8X1FE-TX-V2 ok 03:18:28
0/2 SPA-2XCT3/DS0 ok 03:18:19
1 ASR1000-SIP10 ok 03:19:46
1/0 SPA-2XOC3-POS ok 03:18:28
1/1 SPA-8XCHT1/E1 ok 03:18:28
1/2 SPA-2XT3/E3 ok 03:18:18
R0 ASR1000-RP1 ok, active 03:19:46
F0 ASR1000-ESP10 ok, active 03:19:46
P0 ASR1006-PWR-AC ok 03:19:14
P1 ASR1006-FAN ok 03:19:14
Preparing for Online Removal of a SPA
The Cisco ASR 1000 Series Routers support OIR of a SPA independently of removing the SIP. This
means that a SIP can remain installed in the Cisco ASR 1000 Series Router with one SPA remaining
active, while you remove another SPA from one of the SIP subslots. If you are not planning to
immediately replace a SPA into the SIP, then be sure to install a blank filler plate in the subslot. The SIP
should always be fully installed with either functional SPAs or blank filler plates.
If you are planning to remove a SIP along with its SPAs, then you do not need to follow the instructions
in this section. To remove a SIP, see the
“Preparing for Online Removal of a SIP” section on page 5-2
.