Step 1
Ensure that all power sources have been disconnected from the access point.
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit.
Statement 1028
Note
If your access point contains a backup battery pack, you must depress the reset button for
10 seconds or more (see the
“Disabling Backup Battery Power” section on page 3-10
).
Step 2
Open the hinged cover (see the
“Opening the Access Point Hinged Cover” section on page 2-13
for
instructions).
Step 3
Place the two large reels with the small reels on top as shown in
Figure 2-32
.
Step 4
Align the screw holes in the large and small reels, and insert four attachment screws in each of the reel
pairs. Tighten the screws to 3 to 4 in. lbs (0.34 to 0.45 Nm).
Step 5
Remove the plug from the end of the SFP module, and insert the module into the SFP receptacle (see
Figure 2-32
).
Figure 2-32
Fiber-Optic Cable Components
1
Not used
4
Four screws for each reel assembly
2
SFP module slot
5
Fiber-optic connector plug
3
Fiber reels (large reel with small reel on top)