2-47
Cisco Aironet 1520 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-12632-02
Chapter 2 Mounting Instructions
Powering the Access Point
Tip
To forward bridge traffic, add a switch between the power injector and controller. Refer to the
Deployment Guide: Cisco Mesh Networking Solution for more information.
Step 4
Ensure that the antennas are connected and that a ground is attached to the access point before you apply
power to the access point.
Step 5
Connect a shielded outdoor-rated Ethernet (CAT5e or better) cable between the power injector and the
access point’s PoE-in connector (see
).
Step 6
Connect the Ethernet cable to the access point PoE-in port (see
“Connecting an Ethernet Cable to the
Access Point” section on page 2-47
).
Step 7
Continue with the
“What to Do Next” section on page 2-61
.
Connecting an Ethernet Cable to the Access Point
You need to supply these tools and materials:
•
Shielded outdoor-rated Ethernet (CAT5e or better) cable with 0.2 to 0.35 in. (0.51 to 0.89 cm)
diameter
Note
The Ethernet cable from the power injector to the access point must be at least 10 ft
(3.05 m) long. The PoE-out port is disabled when the access point is powered by the power
injector.
•
RJ-45 connector and installation tool
•
Adjustable wrench
To connect the shielded Ethernet cable to the access point, follow these steps:
Step 1
Disconnect power to the power injector, and ensure all power sources to the access point are turned-off.
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit.
Statement 1028
Note
If your access point contains a backup battery pack, you must press the reset button for 10
seconds or more (see the
“Disabling Backup Battery Power” section on page 2-42
).
Step 2
Ensure a 6 AWG ground wire is connected to the access point (see the
).
Step 3
Use an adjustable wrench, a 22 mm socket, or the Sealcon S-2200-WR wrench to remove the Ethernet
connector plug from the access point (see