C i s c o C o n f i d e n t i a l - D r a f t 1
2-8
Cisco Aironet 1500 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-9977-05
Chapter 2 Mounting Instructions
Installation Guidelines
Figure 2-1
Components in a Typical Access Point Installation
142678
1
10
8
9
7
6
5
4
3
2
1
Building roof-overhang
6
Ground
2
Outdoor rated shielded Ethernet cable
1.
User supplied.
1
7
AC power cord
2.
The safety ground wire in the AC power cord must have a ground path to a grounding rod.
2
3
Water drip loop
8
Power injector
3.
The shielded Ethernet cable has a ground path through the power injector and the safety ground wire in the AC power cord.
3
4
10-AWG copper grounding wire
1
9
Ethernet (CAT 5) cable
1
5
Ground rod
1
10
Controller (through a switch)
Warning
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
Note
There is no requirement for external lightening arrestors on the 1510. The power supplies on the 1510
and the PoE in ports have transient voltage surge suppression. In addition, the PoE in port should be used
with shielded cables that are grounded at the access point and power injector.