Cisco 807 Скачать руководство пользователя страница 32

30

      

  

5.

If SIM card is present, then push the SIM card to eject it out of the slot. Install the new SIM card by pushing it into 
the slot until you hear a clicking sound. 

6.

Replace the protective cover and the screws.

Modems

The Cisco IR807 uses the WP7502, WP7504, and WP7601 series modems:

Installing Antennas

There are two TNC connectors on the device. The TNC connectors are used to connect to the 4G modem. The SMA 
connector is for the GPS antenna.

Orient the antennas. For optimum wireless performance, the antennas should be perpendicular with respect to the floor.

If the router is being mounted on a desk, orient the antennas straight up.

To attach the radio antennas to your wireless router, follow these steps:

1.

Manually screw the antenna tight to the TNC connectors on the front of the router. 

2.

Orient the antennas. For optimum wireless performance, antennas should be generally perpendicular to each other.

Dual Antennas

In all cases, an antenna must be connected to the main port. It is highly recommended in order to achieve optimal 
performance that a second antenna is connected to the diversity port:

Sierra Wireless WP7xxx modem series supports SIMO on LTE. WCDMA UMTS HSPA DC-HSPA+ is diversity only, 
without SIMO.

Product

Carrier/Region

Modem 
Used

4G/LTE Bands 
Supported

3G UMTS 
Bands 
Supported

2G 
GSM/CDMA 
Bands 
supported

IR807-LTE-GA-K9

EMEA

WP7502

1, 3, 7, 8, 20

1, 8

E-GSM 900
DCS 1800

IR807-LTE-NA-K9

North 
America/AT&T

WP7504

2, 4, 5, 12, 17, 
25, 26

2, 4, 5

CDMA 
BC0,
BC1
BC1-

IR807-LTE-VZ-K9

Verizon, USA

WP7601

4, 13

N/A

N/A

Содержание 807

Страница 1: ...tems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Cisco 807 Industrial Integrated Services Router Hardware Installation Guide March 2018 Text Part Number ...

Страница 2: ... interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product not authorized by Cisco could void t...

Страница 3: ...This section describes the conventions used in this guide NOTE Means reader take note Notes contain helpful suggestions or references to additional information and material CAUTION This symbol means reader be careful In this situation you might do something that could result in equipment damage or loss of data TIP Means the following information will help you solve a problem The tip information mi...

Страница 4: ...aa Tilanne voi aiheuttaa ruumiillisia vammoja Ennen kuin käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla SÄILYTÄ NÄMÄ OHJEET Attention IMPORTANT...

Страница 5: ...s corporais Antes de iniciar a utilização de qualquer equipamento tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize se com as práticas habituais de prevenção de acidentes Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo GUARDE ESTAS INSTRUÇÕES Advert...

Страница 6: ...ais Antes de trabalhar com qualquer equipamento esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize se com as práticas padrão de prevenção de acidentes Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo GUARDE ESTAS INSTRUÇÕES ...

Страница 7: ...digelse Før du begynder arbejde på udstyr skal du være opmærksom på de involverede risici der er ved elektriske kredsløb og du skal sætte dig ind i standardprocedurer til undgåelse af ulykker Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler der fulgte med denne enhed GEM DISSE ANVISNINGER ...

Страница 8: ... on the code for any other electrical devices than products designated by CISCO The use of cables that are certified by Electrical Appliance and Material Safety Law that have PSE shown on the code is not limited to CISCO designated products Statement 371 WARNING Read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct ...

Страница 9: ...can come into contact with such circuits When installing the antenna take extreme care not to come into contact with such circuits because they may cause serious injury or death For proper installation and grounding of the antenna please refer to national and local codes for example U S NFPA 70 National Electrical Code Article 810 Canada Canadian Electrical Code Section 54 Statement 1052 WARNING N...

Страница 10: ...uct Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are a free service and Cisco currently supports RSS Ve...

Страница 11: ...next generation ruggedized fixed form factor router It is a small form router with 4G for use in ATM POS Telemetry Billboards Enterprise Fleet markets Utilities and other SCADA Supervisory Control and Data Acquisition environments Hardware Overview This section covers the overview of the IR807 SKU Information Table 1 lists the different SKUs available for the Cisco 807 Integrated Services Router A...

Страница 12: ...ble 2 shows Icons and their associated LEDs with descriptions LEDs are visible from the top cover and from the front panel The LEDs allows easy visibility for wall and desk mounted installations regardless of chassis orientation Table 4 shows the Icons without associated LEDs and their descriptions ...

Страница 13: ...n the Alarm Input VPN Off No VPN tunnel Steady Green At least one VPN tunnel is up User Configurable LED GPS GPS Status Off GPS not configured Steady Green GPS configured Slow Flash GPS Acquiring in Standalone GPS Fast Flash GPS Acquiring in Assisted GPS Slow Flash is defined as the LED will be on for 0 25 seconds and off for 0 75 seconds Fast Flash is defined as the LED will be on for 0 25 second...

Страница 14: ... functionality is described in the RSSI LED Table 3 SIM Slots SIM0 SIM1 Off No USIM Green USIM installed and active WWAN Wireless WAN Activity Off Offline On In Service Flash on 200ms off 5 sec No Service Flash on 1 sec off 1 sec Low Power Mode Flash on 5 sec off 200ms Roaming Flash on 400ms off 100ms Data Active ...

Страница 15: ...On Green 75 to 60dBm Off On Green On Green 60dBm On Green On Green On Green Icon Description Icon Description Console USB 2 0 Type A Port for Storage and Networking Grounding point located on side of device Reset Button DC Power Input 12V to 48V DC Power Return Alarm Common Alarm IN Serial Ports Fast Ethernet Ports Antenna 1 TNC Main Antenna 1 TNC Div Warning ...

Страница 16: ...na 2 TNC DIV 2 USB Console Type B 8 Reset Button 3 USB Type A 9 FE1 10 100 Base T RJ 45 4 S0 DTE 10 S1 DCE 5 FE0 10 100 Base T RJ 45 11 External DC Power Input and Alarm 6 GPS SMA 1 Screw hole for protective cover over USB 2 USB Type B under a protective cover Reserved to be used with Modem for external provisioning 3 Screw holes for protective cover over SIMs one on each side 4 SIM0 bottom and SI...

Страница 17: ... page 15 Antennas page 16 Supported Cisco Antennas and Cables page 16 Power Supply page 25 RJ45 Ports page 25 Accessories page 26 Platform Features for Cisco IR807 The following lists the hardware platform features for the Cisco IR807 External Power Entry Nominal 12 to 48VDC Absolute 9 6 to 60VDC 4 pin 3 8 mm EURO power connector External Reset Recovery Push Button WWAN Modem Single multi band 2G ...

Страница 18: ...na type and installation scenario read through the following information Supported Cisco Antennas and Cables The following section lists the supported Antennas and Cables for the Cisco IR807 For detailed information about Cisco Antennas please refer to the following guides Cisco Industrial Routers and Industrial Wireless Access Points Antenna Guide http www cisco com c en us td docs routers connec...

Страница 19: ...mpedance 50 Ohms Output VSWR 2 0 1 Radiation pattern RHCP DC voltage 2 7 12V DC DC current 20 mA over 40 to 85 C temperature range Integrated RF cable 17 ft LMR 100 type SMA m Mechanical and environmental specifications Mount style Vehicular roof or similar stud and nut mount Environment Outdoor vehicular roof transportation ruggedized and qualified to subset of SAE1455 and MILSTD 810G Connectors ...

Страница 20: ...00 degrees 3 dB beam width H plane 360 degrees omnidirectional Polarization vertical and linear Nominal impedance 50 Ohms VSWR 2 5 1 698 to 960 MHz and 2 0 1 1710 to 2690 MHz Radiation pattern omnidirectional Mechanical Specifications Mount style mast mount upright position only Environment outdoor Connector N type socket Antenna length height 9 8 x 1 in 24 9 x 2 45 cm Weight 1 5 lb 0 68 kg Dimens...

Страница 21: ...B 698 to 960 MHz and 17 dB typical 23 dB 1700 to 2700 MHz Isolation 30 dB Polarization slant 45 degrees Nominal impedance 50 Ohms Radiation pattern directional Mechanical specifications Mount style wall or mast mount Environment outdoor Connector dual type N female direct connect or dual 12 in 30 cm Antenna length height 11 6 2 95 cm Temperature Range Operating 22 to 158 degrees F 30 to 70 C Stora...

Страница 22: ...2700 MHz Mechanical specifications H plane 3 dB beam width omnidirectional Polarization linear and vertical Power 3W Cable 15 ft LMR 195 RF connector type N f TNC plug available Mount style ceiling mount Radome PC ABS UV stable black Material substance compliance RoHS compliant Operational temperature 22 to 158 F 30 to 70 C Storage temperature 40 to 185 F 40 to 85 C Environment indoor Dimensions H...

Страница 23: ... x W x D 229 mm x 30 5 mm x 15 mm Mount style direct mount Environment indoor RF Connector TNC m Antenna weight 49 g Temperature rating 31 to 158 degrees F 35 to 70 degrees C Material substance compliance RoHS compliant 4G LTE ANTM O 3 X Description Multiband low profile indoor or outdoor omnidirectional antenna IP67 ingress protection Ceiling mount dual 4G LTE and standalone GPS Electrical Specif...

Страница 24: ...RG174 VW 1 compliant Height and base diameter 90 mm and 137 mm Temperature rating 40 to 185 F 40 to 85 C Mounting 5 8 inch lug with serrated face nut 5 8 inch diameter hole through mounting surface Can be used with the following cable extensions 4G CAB ULL 20 and 4G CAB ULL 50 4G LTE ANTM D Description Omnidirectional dipole antenna is designed for indoor use with Cisco 4G and Cisco 3G wireless In...

Страница 25: ... x 30 5 x 11 mm Temperature rating 22 to 158 F 30 to 70 C Antenna Extension 4G AE015 R Description Single unit antenna extension base 15 ft 457 2 cm Electrical Specifications Frequency range 6 GHz Attenuation less than 3 dB at or below 2 5 GHz Base connector TNC socket Pigtail connector TNC plug Mechanical Specifications Base material Cisco gray UL94 V0 PC ABS plastic Dimensions 2 8 x 2 4 x 1 8 in...

Страница 26: ...o IR807 uses the WP7502 WP7504 and WP7601 series modems The software download page can be found here https software cisco com download navigator html mdfid 286288566 flowid 76082 Region Carrier Modem Used 4G LTE 3G UMTS HSPA 2G GSM GPRS EDGE US Verizon WP7601 700 MHz band 13 1700 2100 MHz band 4 AWS N A N A North America AT T WP7504 700 MHz band 17 1900 MHz band 2 PCS 1700 2100 MHz band 4 AWS 1850...

Страница 27: ...LATED RS232 ports which conforms to EIA 561 standard RS232 pin out is shown in Figure 6 applies to serial 0 and serial 1 but the directions of the DTE and DCE port are opposite The RJ45 pinouts are shown in Figure 4 Figure 4 RJ45 pinouts RS232 Port The RS232 DTE pin out applies to both serial 0 and serial 1 This port is not shared with the Console port Note The RS232 DTE pin out is different from ...

Страница 28: ...rvices Router document associated hardware and the two hole grounding kit Pin Number Description Abbreviation DTE DCE 1 DCE Ready Ring Indicator DSR RI 2 Received Line Signal Detector DCD 3 DTE Ready DTR 4 Signal Ground COM 5 Received Data RxD 6 Transmitted Data TxD 7 Clear To Send CTS 8 Request To Send RTS Table 6 Cisco IR807 Accessories Cisco Part Number Accessory PWR IE50W AC DIN rail mount AC ...

Страница 29: ...not locate the antenna near overhead power lines or other electric light or power circuits or where it can come into contact with such circuits When installing the antenna take extreme care not to come into contact with such circuits because they may cause serious injury or death For proper installation and grounding of the antenna please refer to national and local codes for example U S NFPA 70 N...

Страница 30: ...SR This router can be installed on a table top or other flat horizontal surface mounted on a wall or DIN rail The recommended clearance when horizontally mounted is 1 inch on non connector sides and 2 inches on bottom Stacking heat dissipating objects on top of the router is not allowed I O side clearance is needed as it is required to access the cable connections Clearance is required to attach m...

Страница 31: ... part of the safety design of the product Do not operate the unit without the covers installed Statement 1077 WARNING Hot surface Statement 1079 To access the SIM card in the Cisco IR807 follow these steps 1 Power off the router and disconnect the power cable from the power source 2 Place the router on its bottom and ensure that any installed antennas are carefully oriented or disconnected to be o...

Страница 32: ...ennas to your wireless router follow these steps 1 Manually screw the antenna tight to the TNC connectors on the front of the router 2 Orient the antennas For optimum wireless performance antennas should be generally perpendicular to each other Dual Antennas In all cases an antenna must be connected to the main port It is highly recommended in order to achieve optimal performance that a second ant...

Страница 33: ...ng the router consider cable limitations and wall structure WARNING Read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system Statement 378 To mount the router on a wall or other flat surface follow these steps 1 Mark the location for th...

Страница 34: ...ain on the connectors or mounting hardware Installing a DIN Rail The DIN Rail kit is ordered separately The DIN Rail can be installed in two different orientations horizontally and vertically To attach the DIN rail bracket to the Cisco IR807 follow these steps Mounting the DIN Rail Bracket on the Router 1 First attach the DIN rail bracket to the back of the router The DIN rail bracket mounts in tw...

Страница 35: ...racket over the two mounting holes 3 that correspond to your orientation Then use 13 15 in lbs pounds of torque to screw the bracket onto the router 3 Once the bracket is attached to the router it can be mounted onto the DIN Rail Attaching the Bracket onto the DIN Rail To attach the Cisco IR807 with the bracket to a DIN rail follow these steps Refer to Figure 5 for details ...

Страница 36: ...nt grounding use size 14 AWG 1 6mm or larger copper wire and a ring terminal with an inner diameter of 1 4 in 5 to 7 mm For EN IEC 60950 1 compliant grounding use size 18 AWG 1 02mm or larger copper wire WARNING This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspec...

Страница 37: ... 4 Insert the ground screws 2 into the grounding lug 1 shown in the graphic and attach the lug to the router NOTE if your grounding lug is a single hole type attach it in the same manner as the dual hole using the first hole from the front panel 5 Use a ratcheting torque screwdriver to tighten the ground screw and ring terminal to the router side panel to 3 5 in lb 0 4 N m The torque should not ex...

Страница 38: ...36 ...

Страница 39: ...per ESD protection should be observed Ensure the router is properly grounded Ensure there is proper airflow around the router If you must supply your own cable see the Technical Specifications section on page 41 for cabling specifications If this appendix does not provide specifications for a particular cable we strongly recommend ordering the cable from Cisco Connecting a Terminal or PC to the Co...

Страница 40: ...rt cover must be reinstalled before the router can be deployed in a hazardous environment Connecting to DC Power WARNING This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective device is rated not greater than 10A Statement 1005 WARNING This product requires short circuit overcurrent protection to be provided as part of the building in...

Страница 41: ... and alarm connector on the router front panel NOTE Your connector may not have the labels V RT A A In the labeled connector the pins are V Positive DC power connection RT Return DC power connection A Alarm Common A Alarm Input 2 Identify the connector positive and return DC power connections The connections left to right are 1 Positive DC power connection 2 Return DC power connection 3 Alarm Comm...

Страница 42: ...m connector to the router and remove the connector 6 On the power and alarm connector insert the exposed part of the positive wire into the connection labeled V and the exposed part of the return wire into the connection labeled RT Make sure that you cannot see any wire lead Only wire with insulation should extend from the connector NOTE Use the same method for wiring the alarm connections 1 Power...

Страница 43: ...5 x 11 43 cm Weight 1 lb 8 oz 0 67kg Environmental Operating Ranges Operating Temperature and Altitude 40 to 140 F 40 to 60 C in a sealed NEMA cabinet with no airflow 40 to 158 F 40 to 70 C in a vented cabinet with 40 lfm of air 40 to 167 F 40 to 75 C in a forced air enclosure with 200 lfm of air type tested at 85C for 16 hours NOTE This product has been safety certified up to 60C maximum ambient ...

Страница 44: ...1 489 52 and EN 62311 Cellular Radio EN 301 908 1 EN 301 908 2 EN 301 511 and EN 301 908 13 Compliance IP30 compliant when vertical and cables downward Transportation Storage Conditions Temperature 40 to 85 C 40 to 185 F Humidity 10 95 Altitude 4570 m 15 000 ft Router DC Power Adapter Input Voltage Nominal voltage 12V to 48V DC Absolute 9 6 to 60V DC input Maximum Power Consumption 10 Watts Countr...

Отзывы: