Caution
The fasteners you use to mount an access point on
a ceiling must be capable of maintaining a
minimum pullout force of 20 lbs (9 kg) and must
use all indented holes on the mounting bracket.
Caution
This product and all interconnected equipment
must be installed indoors within the same building,
including the associated LAN connections as
defined by Environment A of the IEEE 802.af
Standard.
Note
Your small cell is suitable for use in environmental air
space in accordance with section 300.22.C of the
National Electrical Code and sections 2-128,
12-010(3), and 12-100 of the Canadian Electrical
Code, Part 1, C22.1. You should not install the power
supply or power injector in air handling spaces.
Note
Use only with listed ITE equipment.