1-47
Cisco 6260 Hardware Installation Guide
OL-2365-02
Chapter 1 Product Overview
Cisco 6260 System Overview
1.2.6 Fan Tray
Two fan trays are installed in the Cisco 6260 chassis below the line cards. Each tray houses four fans.
The compartments for the two fan trays are located side by side near the bottom of the chassis, just above the
PEMs (see
Figure 1-1
for the location of the fan trays in the Cisco 6260 chassis). As you face the chassis,
fan tray 1 is on the left; and fan tray 2 is on the right.
A narrow bezel fits across the chassis to hold the air filters and fan trays in place.
Note
The Cisco 6260 system requires that a fan tray be installed when the system is in operation.
Figure 1-24
shows a close-up view of the fan tray.
Figure 1-24 Cisco 6260 Fan Tray
The fans have two speeds. By default, they run at low speed. The system turns up the fan speed when
•
It senses high temperatures within the chassis.
•
One or more fans fail.
•
The other fan tray is removed.
The fan speed returns to normal (low speed) when
•
Temperatures within the chassis fall to acceptable levels.
•
A missing fan tray is reinstalled in the chassis.
Caution
The fans in both fan trays must run continuously. The system might suffer thermal damage if the fans in either
tray stop for more than 5 minutes.
An air filter is located above each fan tray. The air filters must be removed and cleaned periodically. See
the
“Replacing or Cleaning the Air Filter” section on page 6-2
for instructions on cleaning the air filters.
Note
For hardware specifications for the fan tray, see the
“Fan Tray” section on page A-12
.
26374