4-7
Cisco ASA 5500 Series Hardware Installation Guide
78-17989-01
Chapter 4 Maintenance and Upgrade Procedures
Installing the DC Model
Step 3
Insert the power supply brace and press down until it fits into place, as shown in
Figure 4-8
.
Figure 4-8
Replacing the Power Supply Brace and the AC Power Supply
Step 4
Connect the power connector to the system board.
Step 5
Replace the adaptive adaptive security appliance cover. See
“Replacing the Chassis Cover”
for more
information.
Step 6
Reinstall the network interface cables.
Installing the DC Model
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC
circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit
breaker in the OFF position.
Statement 7
Note
The DC return connection should remain isolated from the system frame and chassis (DC-I). This
equipment is suitable for connection to intra-building wiring only.
To install the DC power model, perform the following steps:
1
Back panel
3
Power supply brace
2
Power supply
4
Front panel