4-5
NEBS Level 3 and ETSI Compliance Kit Installation Guide for Cisco 3620, Cisco 3640, and Cisco 3660 Routers
78-5450-06 B0
Chapter 4 Installation on Cisco 3660 Routers
Installing the Ground Lug
Warning
Before performing any of the following procedures, ensure that power is removed from the DC
circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services
the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the
circuit breaker in the OFF position. To see translations of the warnings that appear in this
publication, refer to the
Regulatory Compliance and Safety Information
document that
accompanied this device.
Step 2
Strip one end of the 6-AWG wire to expose approximately 0.75 in. (20 mm).
Step 3
Crimp the ground lug around the wire. (See
Figure 4-7
.)
Figure 4-7
Crimping the Lug Around the Wire
Step 4
Use the number 2 Phillips screwdriver to fasten the ground lug to the Cisco 3660 router chassis. (See
Figure 4-8
.)
10360