Chapter 3 Troubleshooting
Diagnosing Problems
3-6
Catalyst 2900 Series XL Hardware Installation Guide
78-6461-04
LRE status LED not turned
on.
RJ-21 cable loose or not connected
properly.
Reseat RJ-21 connector and fasten
with screw or cable tie.
Trunk cable defective.
Test trunk cable. If cable is
defective, repair or use alternate
pair.
CPE device absent, not powered, or
defective.
Check LRE CPE device, and refer
to installation guide.
CPE device out of maximum range.
Consider modification to
topology to shorten reach or
improve wiring quality.
Table 3-2
Common Problems and Their Solutions (continued)
Symptom
Possible Cause
Resolution