3-79
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
Chapter 3 Installing the 1552 Series Access Points in Hazardous Locations
Performing Maintenance
Step 7
Install the ground lug and tighten the connection with a Phillips screwdriver. To prevent stripping the
screw threads, do not overtighten.
Step 8
Insert each hot wire into the AC entry terminal block.
Step 9
Use a Phillips screwdriver to tighten the terminal block set screws to secure the wires in the terminal
block.
Step 10
Verify that no bare wire is exposed. If wire is exposed, remove it from the terminal block, adjust the
length, and reinstall.
Step 11
Check your work.
Step 12
Reinstall the AC entry module top cover and tighten the captive screws. Do not overtighten.
Step 13
Close the access point hinged cover. See the
“Closing the Access Point Hinged Cover” section on
for details.
Step 14
Install the Ethernet backhaul cable. See the next section for instructions.
Performing Maintenance
The access point requires minimal periodic or preventive maintenance as it has no moving parts, filters,
lubricants, or mechanical contact components. However, when installed in a hazardous location, periodic
inspections should be conducted in order to ensure that the access point is operating satisfactory. This
section provides information about performing maintenance on an access point installed in a hazardous
location.
Additional maintenance information can be found in
and the
Troubleshooting a Mesh Network Guide.
The troubleshooting document is available at cisco.com at the
following URL:
http://www.cisco.com/en/US/docs/wireless/access_point/1520/troubleshooting/guide/TrbleshtMesh.ht
ml
Warning
Do not disconnect connections to this equipment unless power has been removed or you have verified
that the area is nonhazardous. Secure any external connections that mate to this equipment by using
screws, sliding latches, threaded connectors, or other means provided with this product. Substitution
of components may impair suitability for Class I, Zone 2, Division 2.
Statement 1062
Warning
If you connect or disconnect the console cable with power applied to the unit or any device on the
network, an electrical arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before proceeding.
To verify unit operation, perform POST on the device in a nonhazardous location before installation.
Statement 1080
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Statement 1046
Содержание 1552 Series
Страница 8: ...Contents 8 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide ...
Страница 14: ...xii Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Preface ...
Страница 106: ...A 2 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix A Translated Safety Warnings ...
Страница 120: ...C 16 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix C Channels and Power Levels ...
Страница 128: ...D 24 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix D Access Point Specifications ...