3-65
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
Chapter 3 Installing the 1552 Series Access Points in Hazardous Locations
Installation Details for the 1552SA and 1552SD Access Point
Connecting a Fiber-Optic Cable to the 1552SA or 1552SD Access Point
Note
If a fiber installation kit is required for the installation, please ensure you order the hazardous locations
compliant kit, AIR-1550S-FIB-KIT, and follow the instructions on installing the adapter below.
To connect a fiber-optic cable to the 1552SA or 1552SD access point, follow these steps:
Step 1
Ensure that all power sources have been disconnected from the access point.
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit.
Statement 1028
Step 2
Open the hinged cover (see the
“Opening the Access Point Hinged Cover” section on page 3-58
for
instructions).
Step 3
Align the reel bracket to the AP and attach via two screws (#4-40 x .25 in). Tighten the screws to 5.5 to
6.0 in. lbs (0.62 to 0.68 Nm). (See
.)
Step 4
Align each of the two reels to the installed bracket. Attach each reel to the bracket with four screws
(#2-56 x .31 in). Tighten the screws to 3 to 4 in. lbs (0.34 to 0.45 Nm). (See
.)
Содержание 1552 Series
Страница 8: ...Contents 8 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide ...
Страница 14: ...xii Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Preface ...
Страница 106: ...A 2 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix A Translated Safety Warnings ...
Страница 120: ...C 16 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix C Channels and Power Levels ...
Страница 128: ...D 24 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix D Access Point Specifications ...