Technical Specifications: 

 

• 

Total 2.000 Label Identification

 

• 

Between RFID Antenna and Control Card Max. 100 Meter Cable 

 

• 

Deleting All Memory Label Information with One Button

 

• 

Defining Labels without Button with Master Card

 

• 

5-24 VDC Loop Detector Signal Input

 

• 

Dry Contact Output

 

12-24V DC Supply Voltage

  

 
 
 
 
 
 
 
 
 
 

 

LOOP INPUT  

: Loop Detector 5-24VDC Live Signal Head

 

 

ROLE COM       : Dry Contact Energy Input

 

 

ROLE NO            : Open End at Relay Normal

 

LOAD BUTTON  : Delete and Add Tags Button

 

 

RS485 

B           : RFID Antenna RS485 - B Signal Input End

 

 

RS485 +A           : RFID Antenna RS485 + A Signal Input End

 

 

GND                 : Circuit Supply Voltage Minus Terminal

 

+24 VDC             : Circuit Supply Voltage Live End

 

RFID ANTEN CONNECTION ENDS 

 

No 

 

Color 

 

Details

 

 

Black 

GND  

 

Brown 

GND  

 

Red 

+24V  

 

Orange 

GPIO2 / Wiegand 1  

 

Yellow 

GPIO1 / Wiegand 0  

 

Green 

GPI  

 

Blue 

Network receiver negative end 

 

Purple 

Network receiver positive end 

 

Grey 

Network transmitter negative end 

10 

 

White 

Network transmitter positive end 

11 

 

Light blue 

RS485 negative (-B)  

12 

 

Light Green 

RS485 positive (+A)  

13 

 

Brown 

 White 

RS232 Serial Port Receiver (RX)  

14 

 

Black - White 

RS232 Serial Port Transmitter (TX)  

  

  

LOAD BUTTON

 

 

 

ROLE NO

 

 

 

RS485 

 

-

 

B

 

 

 

RS485 +A

 

 

 

GND

 

 

 

GND

 

 

 

+24

 

 VDC

 

 

 

 

 

LOOP INPUT

 

 

 

ROLE COM

 

 

 