Step 13
Screw a M8 x16 bolt (with flat and lock washers) into the second bolt hole on each side of the access
point (see
Step 14
Ensure that the front of the access point is vertical, and tighten the four bolts to 13 to 15 ft lbs
(17.6 to 20.3 Nm).
Step 15
When using the Cisco Aironet Dual-Band Omnidirectional Antennas, connect them to the access point
as shown in
. Hand-tighten the antennas to the access point.
Step 16
Continue with the
“Grounding the Access Point (all models)” section on page 3-60
the Access Point” section on page 3-71
Working with the Access Point Hinged Cover
This section details opening and closing the protective cover.
Opening the Access Point Hinged Cover
Caution
The hinged cover must not be opened unless the area is considered non-hazardous and the AP has been
powered off.
You need to open the access point hinged cover to access the AC entry terminal block or 24 VDC
terminal block, and when you are installing fiber-optic SFP module and fiber cable take-up reels.
255256
Содержание 1552 Series
Страница 8: ...Contents 8 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide ...
Страница 14: ...xii Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Preface ...
Страница 106: ...A 2 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix A Translated Safety Warnings ...
Страница 120: ...C 16 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix C Channels and Power Levels ...
Страница 128: ...D 24 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix D Access Point Specifications ...