Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
Chapter 3 Installing the 1552 Series Access Points in Hazardous Locations
Grounding the Access Point (all models)
Figure 3-11
Hinged Cover Bolt Tightening Sequence
Grounding the Access Point (all models)
The access point must be grounded before connecting power.
Warning
This equipment must be externally grounded using a customer-supplied ground wire before power is
applied. Contact the appropriate electrical inspection authority or an electrician if you are uncertain
that suitable grounding is available.
Statement 366
Warning
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
In all outdoor installations and when powering the access point with AC power, you must follow these
instructions to properly ground the case:
Step 1
If using insulated 6-AWG copper ground wire, strip the insulation as required for the grounding lug.
Step 2
Use the appropriate crimping tool to crimp the bare 6-AWG copper ground wire to the supplied
grounding lug (Panduit PLCD6-10A-L).
Note
The grounding lug and hardware used must comply with local and national electrical codes.
1 - 6
Tighten the bolts in the numeric order shown, starting with 1.
255257
1
4
5
6
3
2
Содержание 1552 Series
Страница 8: ...Contents 8 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide ...
Страница 14: ...xii Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Preface ...
Страница 106: ...A 2 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix A Translated Safety Warnings ...
Страница 120: ...C 16 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix C Channels and Power Levels ...
Страница 128: ...D 24 Cisco Aironet 1552 Series for Hazardous Locations Installation Guide Appendix D Access Point Specifications ...