Chapter 7 Maintaining the Router
Removing and Replacing AC and DC Power Subsystem Components
7-40
Cisco 12010, Cisco 12410, and Cisco 12810 Router Installation and Configuration Guide
OL-11496-01
Step 12
Set the power switch to the on (1) position.
The (green) Pwr OK indicator on the front of the power supply should light. If the
indicator does not light, see the
“Troubleshooting the AC Power Supply
Installation” section on page 7-34
.
Removing and Replacing a DC PEM
This section contains the procedure to remove and replace an DC power entry
module (PEM) from the chassis.
Cisco 12010, Cisco 12410, and Cisco 12810 series routers are available with
either an original or enhanced capacity DC power supply:
•
—2400 W DC power supply components
•
—2800 W DC power supply components
Figure 7-22 DC PEM Components—2400 Watt
1
Power switch
3
Handles
2
Status indicators
4
Ejector lever
ON
OFF
129274
PWR OK
FAULT
TEMP
PWR OK
FAULT
TEMP
1
4
2
3