Cisco MERAKI CW9166 Скачать руководство пользователя страница 2

• Power over Ethernet: 42.5 - 57 V (802.3at and 802.3bt compliant)

• Power consumption: 30W to 50W (802.3at required)

• Power over Ethernet injector

(MA-INJ-6)

and DC adapter

(MA-PWR-50WAC)

Power over Ethernet injector and DC adapter sold separately

Actual power consumption may vary depending on the AP usage

USB will be disabled when powered by 802.3 at/PoE+

Environment

• Operating temperature: 32 °F to 122 °F (0 °C to 50 °C)

• Storage and Transportation Temperature: -4 °F to 158 °F (-20 °C to 70 °C)

• Humidity: 5 to 95% non-condensing

Physical Security

• Kensington lock hardpoint

* Screws that can be attached to the security hasp of the universal mounting bracket

• Concealed mount plate with anti-tamper cable bay

Product View and Physical Features

Your CW9166 has the following features:

2

Содержание CW9166

Страница 1: ...nt and securing the airwaves The AP also has an additional Bluetooth Low Energy BLE capable radio used for location and other IoT applications In addition the CW9166 has a USB port About this Guide This guide provides instructions on how to install and configure your CW9166 access points This guide also provides mounting instructions and limited troubleshooting procedures For more wireless install...

Страница 2: ...g on the AP usage USB will be disabled when powered by 802 3 at PoE Environment Operating temperature 32 F to 122 F 0 C to 50 C Storage and Transportation Temperature 4 F to 158 F 20 C to 70 C Humidity 5 to 95 non condensing Physical Security Kensington lock hardpoint Screws that can be attached to the security hasp of the universal mounting bracket Concealed mount plate with anti tamper cable bay...

Страница 3: ...ective cover C Kensington lock hard point D Rubber Feet universal mounting bracket slide in points E Cable access bay The Meraki AP comes with the default Cisco universal mounting bracket AIR AP BRACKET 2 that has the following features 3 ...

Страница 4: ...bracket has a security hasp and can be used to secure the access point to the universal mounting bracket Engaging the security screw prevents accidental dislodging and theft 2 Kensington lock The access point contains a hard point that allows it to be secured to any nearby permanent structure using a standard Kensington lock Ethernet Ports The CW9166 features one RJ45 port capable of operating at ...

Страница 5: ... PoE power input and the expected operation of the AP Port0 2 4GHz 5GHz 6GHz Scan IoT USB AT 4x4 4x4 4x4 ON ON OFF BT 4x4 4x4 4x4 ON ON ON CW9166 AP can be powered by PoE power in different modes as mentioned above when using a PoE capable switch They can also be powered by a single 802 3bt capable PoE injector MA INJ 6 Meraki multiGigabit 802 3bt Power over Ethernet Injector It can also be powere...

Страница 6: ...e is in site survey mode Please see the Conducting Site Surveys with MR Access Points for more details The CW9166 access point may be operated in the Run Dark mode for additional security and to reduce the visibility of the access point In this mode the LED will not be illuminated This mode may be enabled through the Meraki Dashboard Package Contents The access point packages contain the following...

Страница 7: ...Cisco Universal Mount Bracket AIR AP BRACKET 2 T Rail mount attachment AIR AP T RAIL R and screws 5 Nos 6 32 x 1 4 included 7 ...

Страница 8: ...e familiar with standard practices for preventing accidents Read the wall mounting instructions carefully before beginning installation Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system This product relies on the building s installation for short circuit overcurrent protection Ensure that the protective ...

Страница 9: ...lly immediately following installation it is recommended that you facilitate a firmware upgrade prior to mounting your AP 1 Attach your AP to power and a wired Internet connection See the Getting Power to the AP section for details 2 The AP will turn on and the LED will glow solid orange If the unit does not require a firmware upgrade the LED will turn either green no clients associated or blue cl...

Страница 10: ... browser on the client machine access the AP s built in web server by browsing http my meraki com Alternatively browse to http 10 128 128 128 Click on the Uplink Configuration tab Log in The default login is the serial number e g Qxxx xxxx xxxx with no password e g Q2DD 551C ZYW3 Configure the static IP address netmask gateway IP address and DNS servers that this AP will use on its wired connectio...

Страница 11: ...are Installation Instructions Choose Your Mounting Location A good mounting location is important to get the best performance out of your access point Keep the following in mind 1 The device should have an unobstructed line of sight to most coverage areas For example if installing in an office filled with workspaces divided by mid height cubicle walls installing on the ceiling or high on a wall wo...

Страница 12: ...g wall or ceiling It is recommended that the AP be mounted to a wall or solid ceiling using the universal mounting bracket for physical security reasons Drop Ceiling Mount using T Rail Mount attachment To mount your AP on a drop ceiling T rail AIR AP T RAIL R included use the included T Rail mount attachment The T Rail mount attachment can be used to mount to most 9 16 15 16 or 1 T rails 1 Place t...

Страница 13: ...onding holes A B or C on the mounting bracket over the mounting holes on the ceiling grid clip 5 Hold the mounting bracket and insert a 6 32 x 1 4 in screw into each of the four corresponding holes A B or C and tighten 13 ...

Страница 14: ...holes on the bracket 2 Use a 0 1360 in 3 4772 mm bit to drill a pilot hole at the mounting hole locations you marked 3 Locate the pilot holes and then insert a fastener not included into each mounting hole and tighten 4 Place the universal mounting bracket over the faster holes and then use screws up to 6 mm in diameter and at least 1 1 4 inch length not included to tighten it flush to the wall 14...

Страница 15: ... 4 round cable junction box or various U S and European outlet boxes mounting screws are not included Using appropriate mounting hardware for your specific type of junction box attach the universal mounting bracket to the junction box Getting Power to the AP If mounting to an electrical junction box feed the Ethernet cable through the cable access hole in the universal mounting 15 ...

Страница 16: ... AP to the universal mounting bracket properly align the access point feet over the keyhole mounting slots on the mounting bracket Since the cradle is already mounted to the wall gently guide the AP towards the mounting cradle until it clicks into place Physical Security Depending on your mounting environment you may want to secure the AP to its mount location The access point can both be secured ...

Страница 17: ... throughout your coverage area You can use the signal strength meter on a laptop smartphone or another wireless device Third Radio and 6 GHz Operation The CW9166 has three client serving W iFi radios capable of operating in 2 4 GHz 5 GHz and 6Hz frequencies On the CW9166 the third Wi Fi radio can be configured to operate either in the 5 GHz frequency band or 6 GHz frequency band The out of the box...

Страница 18: ...hat are spaced every 80 MHz In order to support the PSC based clients and effectively onboard the clients in the least possible time the 6 GHz channel selection in the RF profile for CW9166 Auto RF configuration will be restricted to a set of PSC capable channels The list of the PSC channels is indicated above in green Auto RF will choose a channel that is a PSC supported channel for 20 40 80 and ...

Страница 19: ...g instructions may be useful depending on your issue Check Radio Functionality by Making the AP a Repeater 1 If your AP is acting as a gateway disconnect the Ethernet cable from the LAN while keeping the AP powered on This will switch your AP into repeater mode If no other gateways are within range the AP will begin broadcasting an SSID appended with scanning If you are able to connect to this SSI...

Страница 20: ...ernet cable from the AP 3 Associate to the SSID being broadcasted by the AP If there are no other APs in the network within range the SSID may be appended with scanning 4 Go to my meraki com in your web browser 5 The MAC address on the back of the access point should match the physical address value on the my meraki com Overview page 6 Once you have verified that the MAC address is correct on the ...

Страница 21: ...instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation Additional warranty information can be found at https meraki cisco com support process warranty Support and Additional Information If issues are encountered with device installation or additional help is required contact Meraki Support by l...

Страница 22: ...ion Manual Transportation of equipment should be carried out in the original packaging in covered vehicles by any means of transport The temperature and humidity during transportation must comply with the permissible established ranges of temperature and humidity during storage in the off state specified in the Operation Manual Installation For additional information on Meraki hardware and for oth...

Отзывы: