VCC-G21X31APCL
Rev.900-716-32-00
©2011 CIS Corporation. All rights reserved.
15
C is the code to send the data back from the camera.
Note: Do not set code C when sending the data from PC side.
Remote controller address
Note: Do not save the data into the address other than specified, since it may cause the
damages or malfunction of the camera.
Remote controller data
Set the decimal number (000
~
255) for the remote controller data. Please be noted to set any
dummy data at read control mode.
CR
Be sure to input “CR” to confirm the end of the command.
※
10ms should be waited to send the next command after receiving the response from the camera when
changing the mode in succession.
9. Initial Settings
Gain
001
1:0dB
E-Shutter
002
0:1/36s (Off)
Trigger Mode
004
0: Normal Shutter Mode (Trigger Shutter Mode Off)
Scan Mode
005
0: Full Frame Scan Mode
Manual Gain Control
008
Invalid
Manual Shutter Control
009&010 Invalid
Trigger Polarity
011
0: Positive Input
Output Data Select
013
0:8bit Output Data
Trigger Reset Mode
014
0: H-Synchronous Mode