![CIS Vision:mini VCC-G21X31APCL Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/cis/vision-mini-vcc-g21x31apcl/vision-mini-vcc-g21x31apcl_product-specification-and-operational-manual_2608727010.webp)
VCC-G21X31APCL
Rev.900-716-32-00
©2011 CIS Corporation. All rights reserved.
10
Manual Shutter Control
009&
010
0
~
791:
1/36s
~
1/48000s
※
Set the data of address 002 to 016.
Address 009 MSB and address 010 LSB makes 10bit in total.
Shutter Speed
=
(791-Data) x 35.28μs+20.72μs
at full frame scan
Shutter Speed
=
(791-Data) x 39.80μs+20.72μs
at binning scan
Max Data =
317Bh =
791
Trigger Polarity
011
0:
Positive Input
1:
Negative Input
No Function
012
0:
Fixed. Do not change.
Output Data Selection 013
0:
8 bit output data
1:
10 bit output data
Trigger Reset Mode
014
0:
H-Synchronous Mode
1:
CLK-Synchronous Mode
2:
HV-Sync Reset Mode
Data Save
015
Input 083 to save address 000
~
014 into EEP-ROM.
Note: Please note the followings when using trigger shutter mode.
Re-triggering at H-Synchronous Mode shall be after 2H of CCD read out signal.
Re-triggering at CLK-Synchronous Mode shall be after completion of video output.
Trigger pulse width shall be within the range of over 1HD to less than 1/2 sec.