1.    Scope of Application 

This is to describe VCC-F22S29ACL Power Over Camera Link color CCD Camera.    All specifications contained 
herein are subject to change without prior notice.    Reproduction in whole or in part is prohibited. 

2.  Handling Precautions 

The camera must not be used for any nuclear equipments or aerospace equipments with which mechanical 
failure or malfunction could result in serious bodily injury or loss of human life.    Our warranty does not apply to 
damages or defects caused by irregular and/or abnormal use of the product.   
 
Please observe all warnings and cautions stated below.     
Our warranty does not apply to damages or malfunctions caused by neglecting these precautions. 

 

z

 

Do not use

 

or store

 

the camera in the following extreme conditions: 

¾

 

Extremely dusty or humid places. 

¾

 

Extremely hot or cold places (operating temperature –5  to +45 )

 

¾

 

Close to generators of powerful electromagnetic radiation such as radio or TV transmitters. 

¾

 

Places subject to fluorescent light reflections. 

¾

 

Places subject to unstable (flickering, etc.) lighting conditions. 

¾

 

Places subject to strong vibration. 

 

z

 

Remove dust or dirt on the surface of the lens with a blower. 

 

z

 

Do not apply excessive force or static electricity that could damage the camera. 

 

z

 

Do not shoot direct images that are extremely bright (e.g., light source, sun, etc.), and when camera   

 

is not in use, put the lens cap on.   

 

z

 

Follow the instructions in Chapter 6, “External connector pin assignment” for connecting the camera. 

 

Improper connection may cause damages not only to the camera but also to the connected devices. 

 

z

 

Confirm the mutual ground potential carefully and then connect the camera to monitors or computers.     

  AC leaks from the connected devices may cause damages or destroy the camera. 
 

z

 

Do not apply excessive voltage. (Use only the specified voltage.)    Unstable or improper power supply 

 

    voltage may cause damages or malfunction of the camera. 

Содержание VISION:mini VCC-F22S29ACL

Страница 1: ...VCC F22S29ACL Rev 900 636 32 00 2010 CIS Corporation All rights reserved SXGA Color Camera 49MHz Pixel Clock Camera Link VCC F22S29ACL Product Specification Operational Manual CIS Corporation English...

Страница 2: ...rnal Connector Pin Assignment 12 6 1 6 pins Circular Connector HR10 7R 6PA HIROSE 12 6 2 26pins camera Link connector 12226 1100 00 PL SUMITOMO 3M 12 7 Timing Chart 13 7 1 Horizontal Synchronous Signa...

Страница 3: ...cold places operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to u...

Страница 4: ...r supply voltage may cause noises on the video signals z The rising time of camera power supply voltage shall be less than 10V Max 60ms Please avoid noises like chattering when rising In case of abnor...

Страница 5: ...Frame Scan Mode entire pixels can be read out within approx 1 25s Interface of F22S29ACL complies with camera link standard Key Features Camera settings can be changed via serial communications Select...

Страница 6: ...Resolving power 8bit 10bit at RAW data output 8 bit at RGB data output Sensitivity F4 0 2000 lx Shutter 1 25s Gain 0dB Minimum illumination F1 4 40 lx Shutter 1 25s Gain 12dB Dust or stains in optica...

Страница 7: ...wo conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Durability Vibration Ac...

Страница 8: ...POSI NEGA Selectable Min Trigger Pulse width Over 1 HD Camera Link input LVDS CC1 input Camera Link connector TTL Input Refer to the following drawing HR10 7R 6PA 100 1 K 470p Input Trigger 5V VIH Min...

Страница 9: ...VCC F22S29ACL Rev 900 636 32 00 2010 CIS Corporation All rights reserved 9 4 3 CCD Spectral Response Representative value Lens characteristics and illuminant characteristics are not considered...

Страница 10: ...AW data output 3200K 6 RGB data output 3200K 2 RAW data output spare 7 RGB data output spare 3 RAW data output spare 8 RGB data output spare 4 RAW data manual white balance 9 RGB data manual white bal...

Страница 11: ...amera Link connector 12226 1100 00 PL LVDS 1 6pin circular connector HR10 7R 6PA TTL Output Data Selection 013 0 Set the data of Address 003 to 000 004 RAW 8 bit output data 8 bit output data 1 RAW 10...

Страница 12: ...nk connector 12226 1100 00 PL SUMITOMO 3M Pin No 1 Power IN 12V 2 Trigger IN TTL Level 3 RS 232C RXD option 4 RS 232C TXD option 5 Do not connect 6 GND Pin No Pin No 1 GND 14 GND 2 X0 15 X0 3 X1 16 X1...

Страница 13: ...K LVAL Signal Output Video Signal Output 1360CLK 16CLK 16CLK Active Area DVAL Signal Output 7 2 Vertical Synchronous Signal Timing 7 2 1 Normal Shutter Mode Trigger Shutter Mode OFF Recommended number...

Страница 14: ...output Read OUT signal Video Signal Discharge signal Trigger Input 1 9H a Exposure Time b c SP output Re Trigger Input Cancell Area Re Trigger Input Cancell Area 7 2 2 Trigger Shutter Mode CLK Synchr...

Страница 15: ...ndividual camera R Read mode Please refer to the address table of 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the...

Страница 16: ...and 10ms should be waited to send the next command after receiving the response from the camera when changing the mode in succession 9 Initial Settings Gain 001 1 0dB E Shutter 002 0 1 25s Off White B...

Страница 17: ...datum plane 14 5 29 6 0 3 6 0 3 6 0 3 6 0 3 10 0 3 10 0 3 29 M2 M3 M2 Datum Plane The center of effective pixels shall be within 0 6 to the center of lens mount Inclination of effective pixels to dat...

Страница 18: ...41 28 12 29 DC IN 12 2 M2 Depth 3 4 5 999 497 00 00 3 4 5 12 20 3 M3 Depth 3 Product Name Label Position 4 M2 Depth 3 C Mount 23 7 M3 Size 22 M2 Size C Mount screws comply with ANSI ASME B1 1 1 32UN...

Страница 19: ...malfunction or non function of the equipment we shall be exempted from responsibility for such damages In case damage or losses are caused by failure to observe the information contained in the instr...

Страница 20: ...would like us to investigate on the cause and repair please contact your distributors you purchased from to consult and coordinate Control SW Sample software for camera control RS 232C can be downloa...

Отзывы: