VCC-SXCXP3R Rev. 905-0050-00
©2017 CIS Corporation. All rights reserved.
21
※
Note
・
Link configuration shall be determined in advance to start each setting.
・
Restrictions on trigger input timing for sequence control operation are the same as the one for normal mode.
・
SequencerActivation shall be turned OFF once, before setting settings for sequence control.
・
With SequencerMode, UserSetSave and UserSetDefault are invalid, therefore, set them after turning power ON.
(With other settings for sequence, UserSetSave and UserSetDefault are valid).
・
If any triggers had been input to the camera, sequence starts when it is set to other than SequencerActivation
OFF. Do not input any triggers when changing SequencerActivation setting.
・
For exposure time to input to each parameter set, please refer to the maximum exposure time in the chart of
Exposure Time: Manual Shutter Mode, in Section 8.2.
・
In case of burst mode, it stops at the last screen when sequence control is completed. And, if a trigger is
input then, it operates to capture image for one frame with the last status of the parameter set. To restart
burst mode operation, turn OFF SequencerActivation once.
・
Turn SequncerActivation OFF to return to the status before sequence control function was operated.
9.2 Trigger Mode Operation and Burst Mode
Operation Outline
This is the mode to specify Index transition flow in advance. The repeating count for each Index, the number of the
Index to be used, and Loop count can be set.
・
Trigger Mode
Index repeat count is increased every time trigger is input externally, and its specified parameter set is applied
to the camera.
・
Burst Mode
Operation is equivalent to the one for internal sync mode, free run operation. Sequence starts with the
trigger, and Index repeat count is increased automatically with the camera internal trigger, then its specified
parameter set is applied to the camera.
Shutter
Gain
Param
#0
Shutter
Gain
Param
#1
Shutter
Gain
Param
#
2
Shutter
Gain
Param
#3
Shutter
Gain
Param
#4
Shutter
Gain
Param
#8
Applying param
Index
0
Applying param
Index
1
Applying param
Index2
Applying param
Index
3
Applying param
Index
#4
Applying param
Index
#5
Param
#0
Param
#1
Param
#0
Param
#1
Param
#4
Param
#8
200
32
100
32
60
3
1023
1
IndexLoopCount
SequencerLoopCount
ActiveIndexNumber
ParameterIndexNumber
SequencerParameterSetSelector