900-548-30-00
9
Pulse Width Trigger Mode
Shutter value can be set by trigger pulse width.
Trigger pulse width shall be within over 1HD to 1/2 sec.
When V-Sync reset operation, it can be controlled 1HD basis.
Approximate
exposure
time
Exposure Time = Trigger Pulse Width (nHD) + 1.6 HD (HD = 39.11
μ
s)
Note: Please note the followings when using trigger shutter mode.
Re-triggering at V-Sync reset operation shall be after 2H of CCD read out signal.
Re-triggering at HV-Sync reset operation shall be after completion of video output.
5.5. Remote Interface Function
Through RS-232C interface via 6 pin of circular connector or 26 pin of camera link connector, the camera can
be controlled by external PC.
(1) The settings for RS-232C are as follows.
Baud rate:
9600 bps
Data: 8
bits
Start bit:
1 bit
Stop bit:
1 bit
Parity: None
XON/XOFF:
not
controlled
(2) Control code
・
The total control code is 14 bits, which conforms to ASCII code.
・
The control code consists of camera No. process code, remote controller address, remote
controller data, and CR. Execute Read/Write through PC, and the camera will reply the data.
1
2
3
4
5
6
7
th Byte
8
9
10 11 12 13 14
Camera No.
Process code
Remote controller
address
Remote controller
data
CR
“R” Read mode
“W” Write
mode
00000: Common to the all
cameras.
000001
〜
ZZZZZZ: Camera
No. of individual camera.
“C” Camera
mode
Please refer to the
address table of
5.4 function
setting.
000
〜
255
0 Dh