900-548-30-00
10
Camera No. shall consist of 6 bytes of characters/numeric strings.
Send the individual camera number code or common number code, “000000”.
The reply data from the camera shall contain the registered number for that camera.
Process code
Input any one of R, W, or C to the process code.
R (read mode) is to read the data of remote controller address.
Please be noted to set any dummy data (000
〜
255) to 11
th
〜
13
th
, since a command shall
consists of 14 bytes.
W (write mode) is to write the data to the remote controller address.
Please be noted that the data cannot be saved into EEPROM of the camera.
(Reboot the camera, and the data is reset to the initial setting.)
To save the data into EEPROM, please refer to Clause 5.4. Function Setting.
Note: Once the data was saved into EEPROM, it may not be reset to t he initial
settings.
C is the code to send the data back from the camera.
Note: Do not set code C when sending the data from PC side.
Remote controller address
Note: Do not save the data into the address other than specified, since it may cause
the damages or malfunction of the camera.
Remote controller data
Set the decimal number (000
〜
255) for the remote controller data. Please be noted to set any
dummy data at read control mode.
CR
Be sure to input “CR” to confirm the end of the command.