VCC-G20V30A
Rev.900-621-34-00
©2010 CIS Corporation. All rights reserved.
6
Item Specification
Power requirements
DC +12V
±
10% (Max voltage not to exceed 15V)
Power consumption
1.6 W typ (max. 2W) at DC +12V IN
Dimension
Refer to overall dimension drawing (Clause 9)
29mm x 29mm x 29mm (excluding projection)
Mass Approx.
45
g
Lens mount
C mount (Refer to overall dimension drawing)
Optical axis accuracy Refer to drawing for CCD Optical Axis Accuracy (Clause 8)
Gain variable range
0
~
12dB (guaranteed range)
Gamma 1
(fixed)
Shutter speed
variable range
Switch:
60fps Mode: OFF(1/60), 1/200, 1/500, 1/1000, 1/2000, 1/4000, 1/8000, 1/20000s
30fps Mode: OFF(1/30), 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000s
Pulse Width: 10
μ~
250ms
Operation Mode
Fixed Trigger Shutter Mode (Exposure time can be set with rear switch).
Pulse Width Trigger Shutter Mode (Exposure time can be set with trigger pulse
width.)
Safety/Quality
standards
UL: Conform to UL Standard including materials and others.
RoHS: Conform to RoHS
CE: Conform to EN55022:2006 (Class B): Emission
Conform to EN61000-6-2:2005: Immunity
Conform to FCC Class A digital Device
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Durability
Vibration
Acceleration 98
m/s
2
(10.0G)
Frequency
20
~
200 Hz
Direction XYZ
3
directions
Testing time
120 min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for
±
X,
±
Y,
±
Z, 6 directions. (without package)
Operation environment
Temperature Operation guaranteed: -5
℃~
+45
℃
Performance guaranteed: 0
℃~
+40
℃
Humidity
RH 20
~
80% with no condensation
Storage environment
Temperature -25
℃
~
+60
℃
Humidity
RH 20
~
80% with no condensation