VCC-G20S20B
Rev.900-740-33
©2014 CIS Corporation. All rights reserved.
6
Item
Specification
Shutter speed
variable range
<Normal Shutter Mode>
OFF (1/15), 1/100, 1/250, 1/500, 1/1,000, 1/2,000, 1/5,000, 1/10,000s
<Trigger Shutter Mode>
1/30, 1/100, 1/250, 1/500, 1/1,000, 1/2,000, 1/5,000, 1/10,000s
Pulse Width: 9
μ
s
~
250ms
Shutter mode
・
Normal shutter mode
・
Restart reset mode
・
Fixed trigger shutter mode
・
Pulse width trigger shutter mode
Safety/Quality
standards
UL: Conform to UL Standard including materials and others.
RoHS: Conform to RoHS
CE: Conform to EN55022:2010 (Class B): Emission
Conform to EN61000-6-2:2005: Immunity
FCC: Conform to FCC Class A digital Device
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Durability
Vibration
Acceleration
98 m/s
2
(10.0G)
Frequency
20
~
200 Hz
Direction
X, Y, and Z
3 directions
Testing time
120 min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for
±
X,
±
Y, and
±
Z, total 6 directions. (without package)
Operation environment
Temperature
Operation guaranteed: -5
℃~
+45
℃
Performance guaranteed: 0
℃~
+40
℃
Humidity
RH 20
~
80% with no condensation
Storage environment
Temperature
-25
℃
~
+60
℃
Humidity
RH 20
~
80% with no condensation