background image

VCC-FC21U19OP 

 

Rev. 900-766-30-00 

   

©2014 CIS Corporation. All rights reserved. 

21 

 

 

9.

 

Remote Communication Function 

Via Opt:C-LINK connector, the camera can be controlled. 

 

(1)

 

The settings for RS232C 
 

Baud rate 

:

 

9600bps (fixed) 

Data 

:

 

8bit 

Stop bit 

:

 

1bit 

Parity 

:

 

None 

XON/XOFF 

:

 

Not controlled 

                 

       

* Baud rate can be changed with address 030.    Please reboot the camera after changing baud rate setting.   

 

(2)

 

Control code 

 

・ 

The total control code is 14 bytes, which conforms to ASCII code. 

 

・ 

The control code consists of camera No. process code, remote controller address, remote   

   controller data, and CR. Execute Read/Write through PC, and the camera will reply the data. 

 

7th Byte 

10 

11 

12 

13 

14 

Camera No. 

Process code 

Remote controller 

address 

Remote controller data 

CR 

000000: fixed 

 

“R” Read mode 

Please refer to the 

address table of Section 

5. Function Settings. 

000

255 

0 Dh 

“W” Write mode 

“C” Camera mode 

00EEEE:4digit error code 

“X” Error   

0   

 

    0          0 

0           

 

0              0 

 

Camera number 

 

Camera No. is fixed with 6 bytes numerical strings, “000000”. 

 

Process code 

 

Input any one of R, W, or C to the process code. 

 

R (read mode) is to read the data of remote controller address. 

Please be noted to set any dummy data (000

255) to 11

th

 

13

th

, since a command shall consists of 14 

bytes. 

 

 

 

W (write mode) is to write the data to the remote controller address. 

 

Please be noted that the data cannot be saved into EEPROM of the camera. 

 

(Reboot the camera, and the data is reset to the one before writing.) 

 

To save the data into EEPROM, please refer to Section 5. Function Settings. 

 
 

C is the code to send the data back from the camera. 

 

Note: Do not set code C when sending the data from PC side. 

Содержание VCC-FC21U19OP

Страница 1: ...CC FC21U19OP Rev 900 766 30 00 2014 CIS Corporation All rights reserved Optical I F UXGA Resolution CMOS Color RAW Camera VCC FC21U19OP Product Specification Operational Manual CIS Corporation English...

Страница 2: ...13 6 2 Optical Module Connector AFBR 57D9AMZ AVAGO 14 6 3 Optical LINK LED 14 7 Timing Chart 15 7 1 Horizontal Synchronous Signals Timing 2Tap Base Configuration mode 63fps 15 7 2 Vertical Synchronou...

Страница 3: ...ground potential carefully before connecting the camera to other equipments AC leaks from the connected devices may cause damages or destroy the camera Do not apply excessive voltage Use only the spe...

Страница 4: ...Fixed trigger shutter mode pulse width trigger shutter mode Enables 150m long distance transmission with optical fiber cable No radio interference or grand noise concerned owing to optical fiber cable...

Страница 5: ...at Sensor AD 10bit Opt C LINK output 8bit 10bit Color RAW output 9 Sensitivity F4 0 2000lx at Shutter speed 1 126s OFF Gain 0dB and Medium Configuration mode 10 Minimum illumination F1 4 50lx at Shutt...

Страница 6: ...interference that may cause undesired operation 25 Durability Vibration Acceleration 98m s2 10G Frequency 20 200 Hz Direction X Y and Z 3 directions Testing time 120min for each direction Shock No ma...

Страница 7: ...D 14 333us 4Tap Medium Configuration mode 1HD 7 167us Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input CC1 Ca...

Страница 8: ...VCC FC21U19OP Rev 900 766 30 00 2014 CIS Corporation All rights reserved 8 4 3 Spectral Response Representative Value Lens characteristics and luminous source characteristics are not considered...

Страница 9: ...0 00 2014 CIS Corporation All rights reserved 9 4 4 Video Output Format 1 2Tap Base Configuration Mode 63fps 2 4Tap Base Configuration Mode 126fps Initial Setting 1088 Line 2048pixel 1 G B 2 1088 Line...

Страница 10: ...1 30000s 1 30000s 15 1 30000s 1 40000s 16 Manual Shutter Refer to Address 036 and 037 White Balance 003 0 Through 1 3200K 2 Through 3 Through 4 Manual White Balance Refer to Address 046 047 048 049 a...

Страница 11: ...Medium Configuration Mode 126fps 2 2Tap Base Configuration Mode 63fps Manual Gain 032 033 0 767 0 0dB 767 12dB Manual Shutter 036 037 0 1087 2Tap mode Shutter Speed 18 49us 1088 036 037 14 333us Min v...

Страница 12: ...1088 Set 0 when not in use Partial scan effective line numbers 3 084 085 1 1088 Set 0 when not in use Partial scan effective line numbers 4 086 087 1 1088 Set 0 when not in use Partial scan effective...

Страница 13: ...2014 CIS Corporation All rights reserved 13 6 External Connector Pin Assignment 6 1 6 Pins Circular Connector HR10 7R 6PA HIROSE Equivalent Pin No 1 Power IN DC 12V 2 Trigger Input 3 FVAL Output 4 Exp...

Страница 14: ...00 2014 CIS Corporation All rights reserved 14 6 2 Optical Module Connector AFBR 57D9AMZ AVAGO LC duplex Connector 6 3 Optical LINK LED 1 Opt C LINK LINK LED The LED is lit when connecting the camera...

Страница 15: ...ap Base Configuration mode 63fps 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 63fps FVAL Out 1Frame 1104H 15 824ms Effective Line 1088H Effective Line DVAL Out LVAL Out Effecti...

Страница 16: ...ration Mode 126fps Initial Setting 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode 126fps FVAL Out 1Frame 1104H 7 912ms Effective Line 1088H Effective Line DVAL Out LVAL Out Eff...

Страница 17: ...be accepted even when outputting video signals However trigger signals to start the next video output before completion of the prior video output signals cannot be accepted Trigger input during exposu...

Страница 18: ...D to approx 2 frames Functionally there is no upper limitation but noises such as dark noises and shadings may be noticeable at long time exposure Triggers can be accepted even when outputting video s...

Страница 19: ...ideo Out Partial Scan Setting Partial scan start position 1 Address 064 065 Partial scan start position 3 Address 068 069 Partial scan effective lines 2 Address 082 083 Partial scan start position 2 A...

Страница 20: ...should be met Frame rate 1 Entire frame line numbers x Time for 1 line Time for 1 line Camera Mode Time for 1 Line 2Tap Base Configuration Mode 14 333us 4Tap Medium Configuration Mode 7 167us Setting...

Страница 21: ...troller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode 00EEEE 4digit error code X E...

Страница 22: ...e end of the command Note The data set with 2 Byte shall be set with High Byte even address first then set with Low Byte odd address The camera rewrites the internal resister when receiving Low Byte 3...

Страница 23: ...VCC FC21U19OP Rev 900 766 30 00 2014 CIS Corporation All rights reserved 23 11 CMOS Optical Axis Accuracy...

Страница 24: ...VCC FC21U19OP Rev 900 766 30 00 2014 CIS Corporation All rights reserved 24 12 Dimensions...

Страница 25: ...used by use contrary to the instructions in this product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software...

Отзывы: