VCC-FC21FR19PCL
Rev. 900-760-31
©2016 CIS Corporation. All rights reserved.
6
(7)
Sensitivity
F5.6
2000lx (at Shutter speed 1/75s (OFF), Gain 0dB, and Medium Configuration mode)
(8)
Minimum illumination
F1.4 30.0lx (at Shutter speed 1/75s (OFF), Gain +12dB, and Medium Configuration mode)
(9)
Dust or stains in optical
system
No dust or stain shall be detected on the testing screen with setting the camera aperture at F16.
(10)
Power requirements
PoCL
(11)
Power consumption
2.7W (4Tap Medium Configuration mode, Full frame scan output): Initial setting.
4.0W (8Tap Full Configuration mode, Partial scan 100lines output)
(12)
Dimensions
Refer to overall dimension drawing. (H:29mm W:29mm D:45mm excluding projection)
(13)
Weight
Approx. 75g
(14)
IR Cut Filter
With
(15)
Lens mount
C Mount * Refer to overall dimension drawing.
(16)
Optical axis accuracy
Refer to drawing for CMOS Optical Axis Accuracy.
(17)
Gain variable range
0dB
~
+12dB (Guaranteed range)
(18)
White Balance Adjustment
Range
2800
~
9000K (Manual White Balance ) (Guaranteed range)
(19)
Shutter speed variable
range
OFF
~
1/50000s
(20)
Trigger shutter mode
Fixed Shutter Trigger Mode/ Pulse Width Shutter Trigger Mode
(21)
Partial Scan
Full Frame Scan
~
1 line (1 line / step)
(22)
Safety/Quality standards
UL: Conform to UL Standard including materials and others.
CE:
EN55022:2010 Class A for Emission
EN61000-6-2:2005 for Immunity
RoHS:
Conform to RoHS.
FCC:
To be applied to FCC Class A digital Device
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
(23)
Durability
Vibration
Acceleration
: 98m/s
2
(10G)
Frequency
: 20
~
200 Hz
Direction
: X,Y, and Z 3 directions
Testing time
: 120min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for
±
X,
±
Y, and
±
Z,
6 directions. (without package)
(24)
Operation Environment
Temperature
Performance guaranteed temperature: 0
℃
~
+40
℃
Camera operation guaranteed temperature: -5
℃
~
+45
℃
※
All the specifications specified in this manual is guaranteed under
performance guaranteed temperature.
※
All the camera functions operate normally under operation guaranteed
temperature.
Humidity
RH 20
~
80% with no condensation.
(25)
Storage Environment
Temperature
-25
℃
~
+60
℃
Humidity
RH 20
~
80% with no condensation.