background image

VCC-FC21FR19OP  

Rev.900-764-30-00 

   

©2013 CIS Corporation. All rights reserved. 

 

 

1.

 

Scope of Application 

 
This is to describe VCC-FC21FR19OP, 4M resolution, Power over Optical I/F Color CMOS Camera.     
All specifications contained herein are subject to change without prior notice.    Reproduction in whole or in 
part is prohibited. 
 
2.  Handling Precautions 
 
The camera must not be used for any nuclear equipments or aerospace equipments with which mechanical 
failure or malfunction could result in serious bodily injury or loss of human life.  Our warranty does not 
apply to damages or defects caused by irregular and/or abnormal use of the product.     
 
Please observe all warnings and cautions stated below.     
Our warranty does not apply to damages or malfunctions caused by neglecting these precautions. 
 

z

 

Do not use

 

or store

 

the camera in the following extreme conditions: 

¾

 

Extremely dusty or humid places. 

¾

 

Extremely hot or cold places (operating temperature –5  to +4

5 )

 

¾

 

Close to generators of powerful electromagnetic radiation such as radio or TV transmitters. 

¾

 

Places subject to fluorescent light reflections. 

¾

 

Places subject to unstable (flickering, etc.) lighting conditions. 

¾

 

Places subject to strong vibration. 

 

z

 

Remove dust or dirt on the surface of the lens with a blower. 

 

z

 

Do not apply excessive force or static electricity that could damage the camera. 

 

z

 

Do not shoot direct images that are extremely bright (e.g., light source, sun, etc.), and when camera   

 

is not in use, put the lens cap on.   

 

z

 

Follow the instructions in Chapter 6, “External connector pin assignment” for connecting the camera. 

  Improper connection may cause damages not only to the camera but also to the connected devices. 

 

z

 

 

Confirm the mutual ground potential carefully and then connect the camera to monitors or

 

 

    computers.    AC leaks from the connected devices may cause damages or destroy the camera. 

 

z

 

 

Do not apply excessive voltage. (Use only the specified voltage.)  Unstable or improper power 

 

    supply voltage may cause damages or malfunction of the camera.

 

Содержание VCC-FC21FR19OP

Страница 1: ...VCC FC21FR19OP Rev 900 764 30 00 2014 CIS Corporation All rights reserved Optical I F 4M Resolution CMOS Color RAW Camera VCC FC21FR19OP Product Specification Operational Manual CIS Corporation English ...

Страница 2: ...AFBR 57D9AMZ AVAGO 13 6 3 Optical LINK LED 13 7 Timing Chart 14 7 1 Horizontal Synchronous Signals Timing 2Tap Base Configuration mode 34fps 14 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 34fps 14 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps Initial Setting 15 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps 15 ...

Страница 3: ...y hot or cold places operating temperature 5 to 4 5 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration z Remove dust or dirt on the surface of the lens with a blower z Do not apply excessive force or static electric...

Страница 4: ...ing is set the faster the camera exposure output speed goes and the more power consumption is required at the same time Power requirement of when the minimum read out line is set with partial scan will be approx 5 0W while the one with full frame scan will be approx 4 5W Naturally heat of the camera will be increased Especially when the read out line is set in the range of 100 lines to 1 line heat...

Страница 5: ...e Diagonal Length 15 930mm Global Shutter type Color CMOS Effective pixel number 2048 H x 2048 V Unit cell size 5 5μm H x 5 5μm V Image Circle φ15 930mm 2 Video Output Frequency Pixel Clock 72 MHz 2Tap Base Configuration Mode Horizontal frequency 69 768 kHz Horizontal clock 1032 CLK Vertical frequency 33 802 Hz Scanning lines 2064 H 4Tap Medium Configuration Mode Horizontal frequency 139 534 kHz H...

Страница 6: ...idth Shutter Trigger Mode 23 Partial Scan Full Frame Scan 1 line 1 line step 24 Safety Quality standards UL Conform to UL Standard including materials and others CE EN55022 2010 Class A for Emission EN61000 6 2 2005 for Immunity RoHS Conform to RoHS FCC To be applied to FCC Class A digital Device This device complies with Part 15 of the FCC Rules Operation is subject to the following two condition...

Страница 7: ... 333us 4Tap Medium Configuration mode 1HD 7 167us Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input CC1 Opt C LINK input Pin No 2 6pins Circular Connector LVTTL 5 Serial Communication SerTC Serial to Camera Opt C LINK input SerTFG Serial to Frame Grabber Opt C LINK output 6 Video Signals White Clip Level At D...

Страница 8: ...VCC FC21FR19OP Rev 900 764 30 00 2013 CIS Corporation All rights reserved 8 4 3 CMOS Spectral Response Representative Value Lens characteristics and luminous source characteristics are not considered ...

Страница 9: ...P Rev 900 764 30 00 2013 CIS Corporation All rights reserved 9 4 4 Video Output Format 1 2Tap Base Configuration Mode 34fps 2 4Tap Medium Configuration Mode 68fps Initial Setting 2048 Line 2048pixel G B G B 1 2 3 4 ...

Страница 10: ... 30000s 1 30000s 15 1 30000s 1 40000s 16 Manual Shutter Refer to Address 036 and 037 White Balance 003 0 Through 1 3200K 2 Through 3 Through 4 Manual White Balance Refer to the address 046 047 048 049 and 050 051 Trigger Shutter Mode 004 0 Normal Shutter Mode Trigger OFF 1 Fixed Trigger Shutter Mode Shutter speed can be set with address 002 2 Pulse Width Trigger Shutter Mode Shutter speed can be s...

Страница 11: ...figuration Mode 68fps 2 2Tap Base Configuration Mode 34fps Manual Gain 032 033 0 767 0 0dB 767 12dB Manual Shutter 036 037 0 2047 2Tap mode Shutter Speed 18 49us 2048 036 037 14 333us Min value 0 29 372ms 1 34s Max value 2047 32 823us 1 30000s 4Tap mode Shutter Speed 18 49us 2048 036 037 7 167us Min value 0 14 697ms 1 68s Max value 2047 25 657us 1 40000s Set the data of the address 002 to 016 Manu...

Страница 12: ...1 2048 Set 0 when not in use Partial scan effective line numbers 3 084 085 1 2048 Set 0 when not in use Partial scan effective line numbers 4 086 087 1 2048 Set 0 when not in use Partial scan effective line numbers 5 088 089 1 2048 Set 0 when not in use Partial scan effective line numbers 6 090 091 1 2048 Set 0 when not in use Partial scan effective line numbers 7 092 093 1 2048 Set 0 when not in ...

Страница 13: ...rcular Connector HR10 7R 6PA HIROSE Equivalent Parts 6 2 Optical Module Connector AFBR 57D9AMZ AVAGO LC duplex Connector 6 3 Optical LINK LED 1 Opt C LINK LINK LED The LED is lit when connecting the camera and the frame grabber board Pin No 1 Power IN DC 12V 2 Trigger Input 3 FVAL Output 4 Exposure Output 5 LVAL Output 6 GND ...

Страница 14: ...0 764 30 00 2013 CIS Corporation All rights reserved 14 7 Timing Chart 7 1 Horizontal Synchronous Signals Timing 2Tap Base Configuration mode 34fps 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 34fps ...

Страница 15: ...764 30 00 2013 CIS Corporation All rights reserved 15 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps Initial Setting 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode 68fps ...

Страница 16: ...ation is H Sync V Sync Reset The delay time Exposure Time Delay from detecting trigger edge in the camera to starting exposure is max 1HD Triggers can be accepted even when outputting video signals However trigger signals for exposure to start the next video output prior to the completion of video transmission for the prior video output signals cannot be accepted Trigger input during exposure time...

Страница 17: ...from detecting trigger edge in the camera to starting exposure and from detecting trigger end edge to completing exposure is max 1HD Pulse width is min 1HD to approx 2 frames Functionally there is no upper limitation but noises such as dark noises and shadings may be noticeable at long time exposure Triggers can be accepted even when outputting video signals However trigger signals for exposure to...

Страница 18: ... Video Out Partial Scan Setting Partial scan start position 1 Address 064 065 Partial scan start position 3 Address 068 069 Partial scan effective lines 2 Address 082 083 Partial scan start position 2 Address 066 067 Partial scan effective lines 3 Address 084 085 0 2047 Partial scan effective lines 1 Address 080 081 Partial scan effective lines 2 Address 082 083 Partial scan effective lines 3 Addr...

Страница 19: ...te 1 Entire frame line numbers x Time for 1 line Time for 1 line Camera Mode Time for 1 Line 2Tap Base Configuration Mode 14 333us 4Tap Medium Configuration Mode 7 167us Setting Example Line numbers at partial scan setting can be set from 1 line However consumption current will increase several hundreds mA more so that the margin of camera power capacity shall be considered Effective Lines Entire ...

Страница 20: ...controller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode 00EEEE 4digit error code X Error 0 0 0 0 0 0 Camera number Camera No is fixed with 6 bytes numerical strings 000000 Process code Input any one of R W or C to the process code R read mode is to read the data of remote controll...

Страница 21: ...onfirm the end of the command Note The data set with 2 Byte shall be set with High Byte even address first then set with Low Byte odd address The camera rewrites the internal resister when receiving Low Byte 3 Data Save Input data 083 or 053 into the address 127 to save the data to EEP ROM 4 Initial Settings Input data 083 or 053 into the address 126 to return to the initial settings 10 Initial Se...

Страница 22: ...VCC FC21FR19OP Rev 900 764 30 00 2013 CIS Corporation All rights reserved 22 11 CMOS Optical Axis Accuracy ...

Страница 23: ...VCC FC21FR19OP Rev 900 764 30 00 2013 CIS Corporation All rights reserved 23 12 Dimensions ...

Страница 24: ... caused by use contrary to the instructions in this product specification operation manual z In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified z In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party such as an unauthorized service representative z E...

Отзывы: