VCC-FC21FR19OP
Rev.900-764-30-00
©2013 CIS Corporation. All rights reserved.
19
□
When setting several partial scan areas, please set the start position and effective lines trying not to
overlap the areas.
□
When setting several areas, please set the areas in the numerical order of starting position.
□
Entire frame line numbers
= V blanking line numbers (16H fixed)
+
Partial
effective
lines 1 + Partial effective lines 2 +
・・・
+ Partial effective lines 8
Note that “Sum total of partial effective line numbers (except V blanking lines)
≦
2048” should be met.
□
Frame rate = 1 / (Entire frame line numbers x Time for 1 line)
Time for 1 line
Camera Mode
Time for 1 Line
2Tap Base Configuration Mode
14.333us
4Tap Medium Configuration Mode
7.167us
□
Setting Example
□
Line numbers at partial scan setting can be set from 1 line. However, consumption current will
increase several hundreds mA more so that the margin of camera power capacity shall be considered.
Effective
Lines
Entire
Frame Lines
Frame Rate (Entire frame lines)
2Tap Mode
4Tap Mode
1(Min) 1
H
17H 4104fps
8208fps
・
・
Vertical:VGA
equivalent
480 H
496H
141fps
281fps
・
・
Vertical:XGA
equivalent
768 H
784H
89fps
178fps
・
・
Vertical:SXGA
equivalent
1024 H
1040H
67fps
134fps
・
・
Vertical:UXGA
equivalent
1200 H
1216H
57fps
115fps
・
・
2048
(Max:Full Frame)
2048 H
2064H
34fps
68fps