VCC-F51U25CL
Rev.900-667-31-01
©2010 CIS Corporation. All rights reserved.
11
Functions
Address Data
Output Data Select
013
0: RGB 24bit Output Data
1: RGB 30bit Output Data
2: RGB 36bit Output Data
Gamma Mode
014
0: Gamma Off(1.0)
1: Gamma On
(Option)
Partial Scan Mode
015
0: Full Frame Scan Mode
1: Partial Scan Mode
Partial Scan Start Position 016&017
0
~
407:
※
Set the data of address 015 to 001.
Address 016 MSB and address 017 LSB makes 16bit in total.
Start Position:3 H/step Min Data:0(0 H) / Max Data:407(1221 H)
Start Position(016&017) + Effective Line(019&020) <= 407
Partial Scan Effective Line 019&020
0
~
407:
※
Set the data of address 015 to 001.
Address 019 MSB and address 020 LSB makes 16bit in total.
Effective Line:3 H/step Min Data:0(3 H) / Max Data:407(1224 H)
Start Position(016&017) + Effective Line(019&020) <= 407
Partial Scan Total Line
021&022
0
~
1251:
Read Only
Total line numbers at Partial Scan Mode or at Full Frame Scan Mode
minus 1H will be set.
Manual Analog Gain
030&031 0
~
512:
0:0dB
~
512: over +12dB (Log Linear)
※
Set the data of address 001 to 004.
Digital Gain G
128&129 256
~
512:
256:×1(0dB)
~
512:×2(+6dB)
Manual White Balance
R
156&157
256
~
1024: 256:×1(0dB)
~
1024:×4(+12dB)
※
Set the data of address 003 to 004.
Manual White Balance
B
158&159
256
~
1024: 256:×1(0dB)
~
1024:×4(+12dB)
※
Set the data of address 003 to 004.
Data Save
255
Input 083 or 053 to save the data to EEP-ROM.
※
Note: When setting the data with 2 Byte, High Byte shall be set first, then Low Byte to the next.
The camera rewrites the internal resister when receiving Low Byte.