background image

VCC-F40V24  

Rev.900-640-32-00

 

©2010 CIS Corporation. All rights reserved. 

 

12

60CLK 54CLK

18CLK

132CLK

78CLK

780CLK

HD Signal Output

Video Signal Output

G Signal (G ON SYNC Mode)

640CLK

4CLK

4CLK

Active Area

525

1

2

3

4

5

6

7

8

9 10

29 30 31 32 33 34

524

523

522

521

35

HD Signal Output

VD Signal Output

WEN Signal Output

Video Signal Output

G Signal (G ON SYNC Mode)

9H

23H

1H

525H

480H

12H

12H

Active Area

7.

 

Timing Chart 

7.1. Horizontal Synchronous Timing Chart 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7.2. Vertical Synchronous Timing Chart 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание VCC-F40V24

Страница 1: ...VCC F40V24 Rev 900 640 32 00 2010 CIS Corporation All rights reserved VGA Color Analog Camera VCC F40V24 Product Specification Operational Manual CIS Corporation English ...

Страница 2: ...esentative value 8 5 Function Settings 9 6 External Connector Pin Assignment 11 7 Timing Chart 12 7 1 Horizontal Synchronous Timing Chart 12 7 2 Vertical Synchronous Timing Chart 12 7 3 Fixed Trigger Shutter Operation SYNC Reset Type 13 7 4 Pulse Width Trigger Operation SYNC Rest Type 13 8 Remote Interface Function 14 9 Initial Settings 15 10 CCD Optical Axis Accuracy 16 11 Dimensions 17 12 Cases ...

Страница 3: ...s operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration z Remove dust or dirt on the surface of the lens with a blower z Do not apply excessive force or static electricity that could damag...

Страница 4: ...oduct Outline VCC F40V24 is a high resolution industrial color analog camera module utilizing a 1 2 type PS IT CCD 330K pixels CCD image sensor with on chip micro lenses realizes high sensitivity and high resolution At Full Frame Scan Mode entire pixels can be read out within approx 1 60s VCC F40V24 is an analog interfaced camera As an optional component parts 12pins connector for power supply HR1...

Страница 5: ...in 0dB 3200K Minimum illumination F1 4 18 lx Shutter 1 60s max Gain VS 50IRE Dust or stains in optical system No dust or stain shall be detected on the testing screen with setting the camera aperture at F16 Power requirements DC 12V 10 Max voltage not to exceed 15V Power consumption 2 5 W at DC 12V IN Dimension Refer to overall dimension drawing Clause 11 44mm x 44mm x 77mm excluding projection Ma...

Страница 6: ...05 Immunity FCC To be applied Durability Vibration Acceleration 98 m s2 10 0G Frequency 20 200 Hz Direction XYZ 3 directions Testing time 120 min for each direction Shock No malfunction shall be occurred with 980m s2 100G for X Y Z 6 directions without package Operation environment Temperature Operation guaranteed 5 45 Performance guaranteed 0 40 Humidity RH 20 80 with no condensation Storage envi...

Страница 7: ...ed by HD recognition Allowable frequency deviation 1 Jitter under 40ns HD VD WEN SYNC output 2 5 0V Negative polarity output Trigger input Polarity Trigger Positive Negative selectable with address 012 Trigger input width Min 2H and over TTL Input Refer to the below VIH Min 4 0V VIL Max 0 5V Video signal VS output 1 0V p p Sync Negative 75Ω unbalanced DC connect White clip level 840 40 30mVp p Exc...

Страница 8: ...VCC F40V24 Rev 900 640 32 00 2010 CIS Corporation All rights reserved 8 4 3 CCD Spectral Response Representative value Lens characteristics and illuminant characteristics are not considered ...

Страница 9: ...Mode Shutter speed can be set with address 002 2 Pulse Width Trigger Mode Shutter speed can be set with trigger pulse width Trigger Polarity 005 0 Positive Input 1 Negative Input No Function 006 0 Do not change SYNC ON OFF 007 0 SYNC OFF 1 G SYNC ON 2 RGB SYNC ON Manual Gain Control 008 0 255 0dB 12dB Set the data of address 001 to 004 Manual Shutter Control 009 010 0 524 1 60 1 12000s Set the dat...

Страница 10: ...by mistake please turn off the power once Data Save 063 Input 083 to save address 000 014 into EEP ROM Fixed Shutter Trigger Mode Fixed Shutter Trigger Mode is a trigger operation to set shutter value exposure time with address 002 Trigger pulse width should be over 2H Pulse Width Trigger Mode Pulse Width Trigger Mode is a trigger operation to set shutter value exposure time with trigger pulse wid...

Страница 11: ...r Connector HR10 10R 12PA HIROSE 9 pins D SUB Connector 6 pins Circular Connector HR10 7R 6PA HIROSE Pin No 1 GND 2 Power In DC 12V 3 GND 4 NA 5 GND 6 HD In Out 7 VD In Out 8 GND 9 NA 10 WEN Out 11 Trig In 12 GND Pin No 1 GND 2 GND 3 R OUT 4 G OUT 5 B OUT 6 NA 7 SYNC OUT 8 GND 9 GND Pin No 1 RS232C TxD 2 RS232C RxD 3 GND 4 NA 5 NA 6 NA ...

Страница 12: ...ut G Signal G ON SYNC Mode 640CLK 4CLK 4CLK Active Area 525 1 2 3 4 5 6 7 8 9 10 29 30 31 32 33 34 524 523 522 521 35 HD Signal Output VD Signal Output WEN Signal Output Video Signal Output G Signal G ON SYNC Mode 9H 23H 1H 525H 480H 12H 12H Active Area 7 Timing Chart 7 1 Horizontal Synchronous Timing Chart 7 2 Vertical Synchronous Timing Chart ...

Страница 13: ...Time ADDRESS 002 Input Trigger Signal Expousure Time VD Signal WEN Signal Video Signal Expousure Time Pulse Width Expousure Time Pulse Width Input Trigger Signal Expousure Time VD Signal WEN Signal Video Signal 7 3 Fixed Trigger Shutter Operation SYNC Reset Type 7 4 Pulse Width Trigger Operation SYNC Rest Type ...

Страница 14: ... Write mode C Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the individual camera number code or common number code 000000 The reply data from the camera shall contain the registered number for that camera Process code Input any one of R W or C to the process code R read mode is to read the data of remote controller address Please be noted to set any dummy data ...

Страница 15: ...g modes consecutively 10ms after receiving reply from the camera should be waited to send the next command 9 Initial Settings Function Address Data Gain 001 0 0dB E Shutter 002 0 1 60s OFF White Balance 003 1 3200K Trigger Mode 004 0 Trigger Mode OFF Trigger Polarity 005 1 Negative Input SYNC ON OFF 007 0 SYNC OFF Manual Gain Control 008 Not specified Manual Shutter Control 009 010 Not specified M...

Страница 16: ...Axis to datum plane 8 77 The center of effective pixels shall be within f 0 6 to the center of the lens mount Inclination of effective pixels to datum plane shall be 0 5 Dimension from datum plane to the center of the lens mount 910 009 00 00 Datum Plane for installation Under 0 5 0 5 Unit mm 10 CCD Optical Axis Accuracy ...

Страница 17: ... OUT IN OFF ON HD VD 75O DC IN REMOTE RGB SYNC Product Name Label 69 26 0 1 4 C Mount screws comply with ANSI ASME B1 1 1 32UN 2B Screw length from C mount lens surface shall be under 6mm And protruding portion shall be less than 10mm 999 489 00 00 4 M3 Depth 4 5 F 32 4 R3 C Mount Unit mm 11 Dimensions ...

Страница 18: ...operation manual In case damage or losses are caused by use contrary to the instructions in this product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party such as a...

Отзывы: