VCC-5CXP3R
Rev. 905-0052-00
©2016 CIS Corporation. All rights reserved.
26
・
FrameBurstStartEdge : To set to start burst mode edge control
・
FrameBurstStartLevel : To set to start burst mode high level control
・
FrameBurstStartSoftware : To set to start burst mode register start
◇
Settings for sequence count and the range
SequencerConfigurationParameter
Setting range
SequencerLoopCount
The loop count of entire sequence
1-1023
0: Infinite
ActiveIndexNumber
The range of Index to be executed
0-15
IndexSelectorModeIndexNumber
The Index no. to be used at Index Mode
0-15
ParameterIndexNumber
Index0-15
Parameter no. of Index0-15
0-15
IndexLoopCount
IndexCount0-15
Each loop count for Index0-15
1-1023
◇
Settings for sequence parameter set
There are 16 types of parameter set. If the number of SequencerParameterSetSelector has changed, the
parameter set will also change. The setting data shall be saved even the parameter no. is changed.
SequencerParameterSetSelector
0
~
15 Parameter Set
SetConfiguration
SequencerExposureTime
Exposure time
(SequencerExposureTimeMAX)
To indicate max. exposure time that can be
set.
SequencerGain
Gain
(SequencerXSize)
X size which is set at ROI shall be set.
(SequencerYSize)
Ysize which is set at ROI shall be set.
(SequencerXStart)
X coordination which is set at ROI shall be set.
(SequencerYStart)
Y coordination which is set at ROI shall be set.
9.7
Sequence Information Output
This function is to indicate the condition of sequence control. Effective image embedding status information can
be output.
SequencerStatus
SequencerInformationLocation
To specify the location of status information
Off
Information output OFF
TopLeft
Top left output
TopRight
Top right output
BottomLeft
Bottom left output
BottomRight
Bottom right output
FrameBurstStatus
To indicate the condition of burst mode for
sequence
IndexNumberStatus
To indicate the executing Index no.
RepeatNumberStatus
To indicate loop count of executing Index no.
LoopNumberStatus
To indicate loop count of executing sequence
※
If the indication of loop count is set to infinite, the
indication of max. loop count is 1023.
Aegis Electronic Group, Inc.