DS584PP5
55
CS42518
6.8
OMCK/PLL_CLK Ratio (address 07h) (Read Only)
6.8.1
OMCK/PLL_CLK RATIO (RATIOX)
Default = xxxxxxxx
Function:
This register allows the user to find the exact absolute frequency of the recovered MCLK coming from
the PLL. This value is represented as an integer (RATIO7:6) and a fractional (RATIO5:0) part. For
example, an OMCK/PLL_CLK ratio of 1.5 would be displayed as 60h.
6.9
RVCR Status (address 08h) (Read Only)
6.9.1
DIGITAL SILENCE DETECTION (DIGITAL SILENCE)
Default = x
0 - Digital Silence not detected
1 - Digital Silence detected
Function:
The CS42518 will auto-detect a digital silence condition when 1548 consecutive zeros have been de-
tected.
6.9.2
AES FORMAT DETECTION (AES FORMATX)
Default = xxx
Function:
The CS42518
will auto-detect the AES format of the incoming S/PDIF stream and display the infor-
mation according to the following table.
7
6
5
4
3
2
1
0
RATIO7(2
1
)
RATIO6(2
0
)
RATIO5(2
-1
)
RATIO4(2
-2
)
RATIO3(2
-3
)
RATIO2(2
-4
)
RATIO1(2
-5
)
RATIO0(2
-6
)
7
6
5
4
3
2
1
0
Digital Silence
AES Format2
AES Format1
AES Format0
Active_CLK
RVCR_CLK2
RVCR_CLK1
RVCR_CLK0
AES
Format2
AES
Format1
AES
Format0
Description
0
0
0
Linear PCM
0
0
1
DTS-CD
0
1
0
DTS-LD
0
1
1
HDCD
1
0
0
IEC 61937
1
0
1
Reserved
1
1
0
Reserved
1
1
1
Reserved
Table 13. AES Format Detection