CDB43131-GBK
56
DS1155V2DB1
6.2.4
Measuring THD+N for the CS43131
To measure THD+N in the WISCE software, click File->Load and select
XTAL_In_ASP_Slave_PCM_Playback_48K_1v7.txt file from {WISCE_INSTALL_FOLDER}/profiles/CS43131 to configure
CS43131 for audio playback in Slave Mode.
6.2.4.1 Measuring THD+N on CSP Device
The following steps show the procedure to measure THD+N.
1. Place a jumper connecting the 600-
Ω load on J15.
2. Place a jumper connecting the 600-
Ω load on J4.
3. Connect a headphone-RCA or headphone-BNC cable between CSP-HPOUT(J1) and the Balanced port on Analog
inputs 1 and 2 on the APx.
Figure 55 THD+N Measurement for CS43131 CSP
4. Configure APx and run THD+N Measurement test as described in section 6.2.2.